Calculite® HID Downlight  C4MRD

Page of 2

4 1/2" Aperture (1) 20W CMH MR16

C4MRDCCLW, 20W G.E. HID SPOT, 12° GX10 BASE

1750

3500

5250

7000

LUMEN RATING = 1000 LMS. SC = .3

TEST REPORT NO. 3405FR

90°

CANDLEPOWER SUMMARY

ZONAL LUMENS AND PERCENTAGES

 

 

 

 

 

 

COEFFICIENTS OF UTILIZATION

 

 

 

 

 

 

Angle

Mean CP

Lumens

ZONE

LUMENS

%LAMP

%LUMINAIRE

 

 

 

 

 

 

ZONAL CAVITY METHOD

 

 

 

 

 

 

 

 

 

 

 

 

EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

 

 

 

 

 

0

6795

 

0-30

857

85.75

 

94.06

 

 

 

 

 

 

 

 

 

 

 

 

CC

 

80

 

 

70

 

 

50

 

30

 

10

 

 

 

5

5107

457

0-40

899

89.97

 

98.69

 

 

 

 

 

 

 

 

 

60°

10

2136

 

0-60

911

91.16

 

100.00

WALL

70

50

30

10

70

50

30

10

50

30

10

50 30 10

50

30

10

0

15

803

293

0-90

911

91.16

 

100.00

RCR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

386

 

40-90

11

1.19

 

1.31

0

1.09

1.09

1.09

1.09

1.06

1.06

1.06

1.06

1.01

1.01

1.01

.97 .97 .97

.93

.93

.93

.91

 

25

207

108

60-90

0

.00

 

.00

1

1.06

1.04

1.03

1.02

1.04

1.03

1.01

1.00

.99

.98

.97

.95 .95 .94

.92

.92 .91 .90

 

30

134

 

90-180

0

.00

 

.00

2

1.03

1.01

.98

.96

1.01

.99

.97

.95

.96

.95

.93

.94 .93 .92

.91

.91

.90

.88

 

35

52

42

0-180

911

91.16

 

100.00

3

1.01

.97

.95

.93

.99

.96

.94

.92

.94 .92 .91

.92 .91 .90

.91 .89

.88

.87

 

40

30

 

 

** EFFICIENCY = 91.2% **

 

4

.99

.95

.92

.90

.98

.94

.92

.90

.92

.90

.89

.91 .89 .88

.89

.88 .87 .86

 

45

16

12

 

 

 

 

 

5

.97

.93

.90

.88

.95

.92

.89

.87

.90

.88

.87

.89 .87 .86

.88

.87 .85 .84

 

50

0

 

 

 

 

 

 

6

.95

.91

.88

.86

.94

.90

.87

.85

.89

.87

.85

.88 .86 .84

.87

.85 .84 .83

 

55

0

0

LUMINANCE SUMMARY

 

 

7

.93

.89

.86

.84

.92

.88

.86

.83

.87

.85

.83

.86 .84 .83

.86

.84 .82 .82

 

60

0

 

ANGLE

MEAN CD/SQ M

 

 

8

.92

.87

.84

.82

.91

.86

.84

.82

.86

.83

.82

.85 .83 .81

.84

.83 .81

.80

 

65

0

0

 

 

9

.90

.85

.83

.81

.89

.85

.83

.81

.84

.82

.80

.84 .82 .80

.83

.81 .80

.79

 

45

2475

 

 

30°

70

0

0

 

 

10

.88

.84

.81

.79

.88

.84

.81

.79

.83

.81

.79

.82 .80 .79

.82

.80 .79

.78

 

75

0

55

 

0

 

 

 

 

 

 

 

 

CU VALUE GREATER THAN 1.00

 

 

 

 

 

 

80

0

 

65

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

determined in accordance with current IES published procedures

 

 

 

 

85

0

0

75

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LUMINAIRE INPUT WATTS = 26.0

 

 

 

 

 

 

90

0

 

85

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tested according to IES procedures.

Test distance exceeds five times the greatest luminous opening of luminaire.

C4MRDCCLW, 20W G.E. HID FLOOD, 25° GX10 BASE

750

1500

2250

3000

LUMEN RATING = 1000 LMS. SC = .4

TEST REPORT NO. 3392FR

90°

CANDLEPOWER SUMMARY

 

ZONAL LUMENS AND PERCENTAGES

 

 

 

 

 

 

 

 

COEFFICIENTS OF UTILIZATION

 

 

 

 

 

 

 

Angle

Mean CP

Lumens

 

ZONE

 

LUMENS

%LAMP

%LUMINAIRE

 

 

 

 

 

 

 

 

ZONAL CAVITY METHOD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

 

 

 

 

 

0

3280

 

0-30

 

836

83.67

 

 

90.41

 

 

 

 

 

 

 

 

 

 

 

5

2896

267

0-40

 

903

90.33

 

 

97.61

 

CC

 

80

 

 

 

70

 

 

50

 

 

30

 

10

 

 

60°

10

2105

 

0-60

 

925

92.54

 

 

100.00

WALL

70

50

30

10

 

70

50

30

10

50

30

10

50

30 10

50

30

10

0

15

1316

386

0-90

 

925

92.54

 

 

100.00

RCR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

715

 

40-90

 

22

2.21

 

 

2.39

0

1.10

1.10

1.10

1.10

 

1.08

1.08

1.08

1.08

1.03

1.03

1.03

.98

.98 .98

.94 .94

.94

.93

 

25

342

184

60-90

 

0

.00

 

 

.00

1

1.07

1.05

1.04

1.02

 

1.05

1.04

1.02

1.01

1.00

.99

.98

.96

.95 .95

.93

.93 .92

.91

 

30

187

 

90-180

 

0

.00

 

 

.00

2

1.04

1.01

.99

.96

 

1.02

.99

.97

.95

.96

.95

.93

.94

.93 .91

.92 .91 .90

.88

 

35

92

67

0-180

 

925

92.54

 

 

100.00

3

1.01

.97

.94

.92

 

1.00

.96

.94

.92

.94 .92 .90

.92

.90 .89

.90

.89 .87

.86

 

40

53

 

 

 

** EFFICIENCY = 92.5% **

 

4

.98

.94

.91

.89

 

.97

.93

.91

.88

.92

.89

.87

.90 .88 .86

.88

.87 .85

.84

 

45

30

22

 

 

 

 

 

 

 

 

5

.96

.91

.88

.85

 

.95

.90

.87

.85

.89

.86

.84

.87 .85 .83

.86

.85 .83

.82

 

50

0

 

 

 

 

 

 

 

 

 

6

.94

.89

.85

.83

 

.93

.88

.85

.83

.87

.84

.82

.86 .83 .82

.85

.83 .81

.80

 

55

0

0

 

LUMINANCE SUMMARY

 

7

.91

.86

.83

.80

 

.90

.85

.82

.80

.84

.82

.80

.83 .81 .79

.83

.80 .79

.78

 

60

0

 

 

 

 

 

 

 

 

 

8

.89

.83

.80

.78

 

.88

.83

.80

.77

.82

.79

.77

.81 .79 .77

.81

.78 .77

.76

 

 

 

ANGLE

 

MEAN CD/SQ M

 

 

65

0

0

 

 

 

9

.87

.81

.78

.76

 

.86

.81

.78

.76

.80

.77

.75

.80 .77 .75

.79

.76 .75

.74

 

45

 

4709

 

 

 

 

30°

70

0

 

 

 

 

 

10

.85

.79

.76

.73

 

.84

.79

.76

.73

.78

.75

.73

.78 .75 .73

.77

.75 .73

.72

 

75

0

0

55

 

 

0

 

 

 

 

 

 

 

 

 

 

 

CU VALUE GREATER THAN 1.00

 

 

 

 

 

 

 

80

0

 

65

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

determined in accordance with current IES published procedures

 

 

 

 

85

0

0

75

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LUMINAIRE INPUT WATTS = 26.0

 

 

 

 

 

 

 

90

0

 

85

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tested according to IES procedures.

Test distance exceeds five times the greatest luminous opening of luminaire.

C4MRDCCLW, 20W G.E. HID FLOOD, 40° GX10 BASE

500

1000

1500

2000

LUMEN RATING = 1000 LMS. SC = .6

TEST REPORT NO. 3391FR

90°

CANDLEPOWER SUMMARY

 

ZONAL LUMENS AND PERCENTAGES

 

 

 

 

 

 

 

 

COEFFICIENTS OF UTILIZATION

 

 

 

 

 

Angle

Mean CP

Lumens

 

ZONE

 

LUMENS

%LAMP

%LUMINAIRE

 

 

 

 

 

 

 

 

ZONAL CAVITY METHOD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

 

 

 

 

0

2247

 

0-30

 

807

80.79

 

 

87.15

 

 

 

 

 

 

 

 

 

 

5

1983

187

0-40

 

896

89.63

 

 

96.69

 

CC

 

80

 

 

 

70

 

 

50

 

30

 

10

 

 

10

1629

 

0-60

 

925

92.56

 

 

99.85

WALL

70

50

30

10

 

70

50

30

10

50

30

10

50 30 10

50

30 10

0

60°

15

1300

366

0-90

 

926

92.70

 

 

100.00

RCR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

934

 

40-90

 

30

3.07

 

 

3.31

0

1.10

1.10

1.10

1.10

 

1.08

1.08

1.08

1.08

1.03

1.03

1.03

.99 .99 .99

.95

.95 .95

.93

 

25

504

255

60-90

 

1

.14

 

 

.15

1

1.07

1.05

1.03

1.02

 

1.05

1.03

1.02

1.00

.99

.98

.97

.96 .95 .94

.93

.92 .92

.90

 

30

261

 

90-180

 

0

.00

 

 

.00

2

1.03

1.00

.98

.95

 

1.02

.99

.96

.94

.96

.94

.92

.93 .92 .91

.91

.90 .89

.87

 

35

120

88

0-180

 

926

92.70

 

 

100.00

3

1.00

.96

.93

.91

 

.99

.95

.92

.90

.93 .91 .89

.91 .89 .87

.89

.88 .86

.85

 

40

62

 

 

 

** EFFICIENCY = 92.7% **

 

4

.97

.93

.89

.87

 

.96

.92

.89

.86

.90

.87

.85

.88 .86 .84

.87

.85 .83

.82

 

45

37

27

 

 

 

 

 

 

 

 

5

.94

.89

.85

.83

 

.93

.88

.85

.82

.87

.84

.82

.86 .83 .81

.84

.82 .80

.79

 

50

5

 

 

 

 

 

 

 

 

 

6

.92

.86

.83

.80

 

.91

.86

.82

.80

.85

.82

.79

.83 .81 .79

.82

.80 .78

.77

 

55

1

2

 

LUMINANCE SUMMARY

 

7

.89

.83

.79

.77

 

.88

.83

.79

.76

.82

.78

.76

.81 .78 .76

.80

.77 .75

.75

 

60

1

 

 

 

 

 

 

 

 

 

8

.87

.80

.77

.74

 

.86

.80

.76

.74

.79

.76

.74

.78 .75 .73

.77

.75 .73

.72

 

 

 

ANGLE

 

MEAN CD/SQ M

 

 

65

1

1

 

 

 

9

.84

.78

.74

.71

 

.83

.77

.74

.71

.76

.73

.71

.76 .73 .71

.75

.72 .70

.70

 

45

 

5737

 

 

 

 

30°

70

0

 

 

 

 

 

10

.81

.75

.72

.69

 

.81

.75

.72

.69

.74

.71

.69

.74 .71 .68

.73

.70 .68

.67

75

0

0

55

 

260

 

 

 

 

 

 

 

 

 

 

 

CU VALUE GREATER THAN 1.00

 

 

 

 

 

80

0

 

65

 

211

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

determined in accordance with current IES published procedures

 

 

 

85

0

0

75

 

157

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LUMINAIRE INPUT WATTS = 26.0

 

 

 

 

 

90

0

 

85

 

200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tested according to IES procedures.

Test distance exceeds five times the greatest luminous opening of luminaire.

Job Information

Type:

 

 

Lightolier a Genlyte company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2006 Genlyte Group LLC • A1007

Page 2
Image 2
Lightolier C4MRD HID manual C4MRDCCLW, 20W G.E. HID SPOT, 12 GX10 Base, C4MRDCCLW, 20W G.E. HID FLOOD, 25 GX10 Base

C4MRD HID specifications

The Lightolier C4MRD HID is a versatile and efficient lighting solution designed to meet the demands of commercial and industrial environments. Known for its high performance and advanced technology, the C4MRD series is an ideal choice for applications such as parking garages, warehouses, and retail spaces.

One of the main features of the C4MRD is its HID (High-Intensity Discharge) technology, which offers superior luminosity compared to traditional lighting solutions. The HID system is known for its energy efficiency and long service life, often exceeding 20,000 hours of operation. This means reduced maintenance costs and prolonged periods between bulb replacements, making it a cost-effective choice for businesses.

The C4MRD HID operates at various wattages, providing flexibility to cater to different lighting needs. Whether high ceilings need bright illumination or expansive areas require consistent light distribution, the C4MRD series is adaptable. It is compatible with various HID lamp types, including metal halide and high-pressure sodium, allowing users to select the light quality and color temperature that best suits their requirements.

Another notable characteristic of the C4MRD is its robust construction. Designed for durability, it features a strong housing that can withstand harsh ambient conditions typical of industrial settings. The finish is resistant to corrosion and impacts, ensuring longevity and reliability in demanding environments.

Additionally, the C4MRD HID is equipped with innovative reflector designs that enhance light distribution efficiency. These reflectors help minimize light loss and ensure that illumination is focused where it is most needed, improving overall lighting quality.

The lighting system also incorporates advanced thermal management technology, which prevents overheating and extends the life of the HID bulbs. This is crucial in maintaining consistent light output and reducing the risk of burnout or failure that can disrupt operations.

Furthermore, the C4MRD series is designed with user-friendly installation in mind. Its lightweight and compact design paired with a mounting bracket simplifies the installation process, allowing for quick set-up without extensive modifications to existing structures.

In summary, the Lightolier C4MRD HID is a powerful and efficient lighting solution featuring advanced HID technology, durable construction, flexible wattage options, and superior thermal management. These attributes make it an exceptional choice for businesses looking to enhance their lighting systems while minimizing operational costs and maintenance.