Calculite® HID Lensed Downlight C4P20MHGD
Page 2 of 2 | 4 1/2” Aperture, PAR 20 Ceramic MH, Glasslite |
39W PAR20 FL, CERAMIC MH, PHILIPS, LUMEN RATING = 2000 LMS., AROMAT 39W ELECTRONIC BALLAST
CANDLEPOWER DISTRIBUTION1,125
2,250
3,375
4,500
| ANGLE | MEAN CP | LUMENS |
| 0 | 4280 |
|
| 5 | 4233 | 391 |
| 10 | 3642 |
|
| 15 | 2241 | 639 |
60° | 20 | 897 |
|
25 | 335 | 194 | |
| 30 | 106 |
|
| 35 | 37 | 31 |
| 40 | 19 |
|
| 45 | 13 | 11 |
| 50 | 11 |
|
| 55 | 9 | 8 |
| 60 | 6 |
|
| 65 | 3 | 4 |
| 70 | 2 |
|
| 75 | 0 | 1 |
| 80 | 0 |
|
30° | 85 | 0 | 0 |
| 90 | 0 |
|
LUMINANCE SUMMARY CD. / SQ. M. |
|
|
|
|
|
| Coefficients of Utilization |
|
|
|
| |||||||
ANGLE | MEAN CD/SQ M |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
45 |
| 1866 |
| CEILING |
|
| 80% |
|
| 70% |
| 50% |
| 30% |
|
| ||
|
|
|
|
|
|
|
|
|
| |||||||||
55 |
| 1598 |
|
|
|
|
|
|
|
|
| |||||||
|
|
| WALL | 70 | 50 | 30 | 10 | 50 | 10 | 50 | 10 | 50 | 10 | 0 |
| |||
65 |
| 795 |
|
|
| |||||||||||||
75 |
| 118 |
|
|
| RCR | Zonal Cavity Method | - Effective | Floor Cavity | Reflectance | = 20% | |||||||
85 |
| 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 0 | .76 | .76 | .76 | .76 | .74 | .74 | .71 | .71 | .68 | .68 | .64 |
| |||
|
|
|
|
|
| |||||||||||||
|
|
|
|
| 1 | .74 | .73 | .72 | .71 | .72 | .70 | .69 | .68 | .67 | .66 | .63 |
| |
|
|
|
|
|
| 2 | .72 | .70 | .69 | .67 | .69 | .66 | .67 | .65 | .65 | .64 | .61 |
|
ZONAL LUMENS AND PERCENTAGES |
| 3 | .70 | .68 | .66 | .64 | .67 | .64 | .66 | .63 | .64 | .62 | .61 |
| ||||
| 4 | .69 | .66 | .64 | .62 | .65 | .62 | .64 | .61 | .63 | .61 | .59 |
| |||||
ZONE LUMENS | % LAMP %LUMINAIRE |
|
| |||||||||||||||
1224 | 61.2 | 95.73 |
| 5 | .67 | .64 | .62 | .60 | .64 | .60 | .62 | .60 | .62 | .59 | .58 |
| ||
1255 | 62.77 | 98.18 |
| 6 | .66 | .63 | .60 | .59 | .62 | .59 | .61 | .58 | .61 | .58 | .57 |
| ||
1274 | 63.72 | 99.66 |
| 7 | .64 | .61 | .59 | .57 | .61 | .57 | .60 | .57 | .59 | .57 | .56 |
| ||
1278 | 63.93 | 100.00 |
| 8 | .63 | .60 | .58 | .56 | .59 | .56 | .59 | .56 | .58 | .55 | .55 |
| ||
23 | 1.16 | 1.82 |
| 9 | .62 | .58 | .56 | .55 | .58 | .55 | .58 | .55 | .57 | .54 | .54 |
| ||
4 | 0.21 | .34 |
|
| ||||||||||||||
| 10 | .61 | .57 | .55 | .54 | .57 | .54 | .57 | .54 | .56 | .53 | .53 |
| |||||
0 | 0 | .00 |
|
| ||||||||||||||
1278 | 63.93 | 100.00 |
|
|
| LUMINAIRE INPUT WATTS = 44.0 |
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
** EFFICIENCY = 63.9% ** SC = 0.5
CERTIFIED TEST REPORT NO. 2434FR, DATE: MAR 11, 2004 COMPUTED BY LSC PROGRAM