Calculite® HID Surface Cylinder C6CS-C6T6VM

Page 2 of 2

6" Aperture, Ceramic Metal Halide, T6 Medium Beam

39W T6 PHILIPS CERAMIC MH LAMP, LUMEN RATING = 3400 LMS, AROMAT ELECTRONIC BALLAST, CL FINISH TRIM

CANDLEPOWER DISTRIBUTION

625

1,250

1,875

2,500

 

ANGLE MEAN CP

LUMENS

 

0

2382

 

 

5

2347

223

 

10

2265

 

 

15

2086

581

 

20

1766

 

60°

25

1385

648

30

1062

 

 

 

 

35

836

518

 

40

566

 

 

45

248

209

 

50

20

 

 

55

3

6

 

60

0

 

 

65

0

0

 

70

0

 

 

75

0

0

 

80

0

 

 

85

0

0

30°

90

0

 

 

 

 

LUMINANCE SUMMARY CD. / SQ. M.

 

 

 

 

 

 

Coefficients of Utilization

 

 

 

 

ANGLE

MEAN CD/SQ M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45

 

21039

 

CEILING

 

 

80%

 

 

70%

 

50%

 

30%

 

 

 

 

 

 

 

 

 

 

 

 

55

 

301

 

 

 

 

 

 

 

 

 

 

 

 

WALL

70

50

30

10

50

10

50

10

50

10

0

 

65

 

5

 

 

 

75

 

19

 

 

 

RCR

Zonal Cavity Method

- Effective

Floor Cavity

Reflectance

= 20%

85

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

.77

.77

.77

.77

.75

.75

.72

.72

.69

.69

.64

 

 

 

 

 

 

 

 

 

 

 

 

1

.74

.72

.71

.69

.71

.68

.68

.66

.66

.64

.61

 

 

 

 

 

 

 

2

.71

.68

.66

.64

.67

.63

.65

.62

.63

.61

.58

 

ZONAL LUMENS AND PERCENTAGES

 

3

.68

.64

.61

.59

.63

.59

.62

.58

.60

.57

.55

 

ZONE LUMENS

% LAMP %LUMINAIRE

 

4

.65

.61

.58

.55

.60

.55

.59

.54

.57

.54

.52

 

0-30

1452

42.71

66.44

 

5

.62

.57

.54

.52

.57

.51

.56

.51

.55

.50

.49

 

0-40

1970

57.94

90.14

 

6

.59

.54

.51

.49

.54

.48

.53

.48

.52

.48

.47

 

0-60

2185

64.28

99.99

 

7

.56

.51

.48

.45

.51

.45

.50

.45

.49

.45

.44

 

0-90

2185

64.28

100

 

8

.54

.48

.45

.42

.48

.42

.47

.42

.47

.42

.41

 

40-90

215

6.34

9.86

 

 

 

9

.51

.46

.42

.40

.45

.40

.45

.39

.44

.39

.38

 

60-90

0

0

0.01

 

 

90-180

0

0

0

 

10

.49

.43

.39

.37

.43

.37

.42

.37

.42

.37

.36

 

0-180

2185

64.28

100

 

 

 

 

LUMINAIRE INPUT WATTS = 44

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

** EFFICIENCY = 64.3% ** SC = 0.9

CERTIFIED TEST REPORT NO. 2337FR, DATE: OCT 24, 2003 COMPUTED BY LSI PROGRAM **TEST-LITE**

70W T6 PHILIPS CERAMIC MH LAMP, LUMEN RATING = 6600 LMS, AROMAT ELECTRONIC BALLAST, CL FINISH TRIM

CANDLEPOWER DISTRIBUTION

1,000

2,000

3,000

4,000

 

ANGLE

MEAN CP

LUMENS

 

0

4188

 

 

5

4141

394

 

10

4047

 

 

15

3813

1062

 

20

3312

 

60°

25

2664

1244

30

2115

 

 

 

 

35

1667

1031

 

40

1114

 

 

45

479

408

 

50

32

 

 

55

3

8

 

60

0

 

 

65

0

0

 

70

0

 

 

75

0

0

 

80

0

 

 

85

0

0

30°

90

0

 

 

 

 

LUMINANCE SUMMARY CD. / SQ. M.

 

 

 

 

 

 

Coefficients of Utilization

 

 

 

 

ANGLE

MEAN CD/SQ M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45

 

40627

 

CEILING

 

 

80%

 

 

70%

 

50%

 

30%

 

 

 

 

 

 

 

 

 

 

 

 

55

 

293

 

 

 

 

 

 

 

 

 

 

 

 

WALL

70

50

30

10

50

10

50

10

50

10

0

 

65

 

0

 

 

 

75

 

0

 

 

 

RCR

Zonal Cavity Method

- Effective

Floor Cavity

Reflectance

= 20%

85

 

0

 

 

0

.76

.76

.76

.76

.74

.74

.70

.70

.67

.67

.63

 

 

 

 

 

 

 

 

 

 

 

 

1

.72

.71

.69

.68

.70

.67

.67

.65

.65

.63

.60

 

 

 

 

 

 

 

2

.69

.67

.65

.62

.66

.62

.63

.60

.62

.59

.57

 

ZONAL LUMENS AND PERCENTAGES

 

3

.66

.63

.60

.58

.62

.57

.60

.57

.59

.56

.54

 

ZONE LUMENS

% LAMP %LUMINAIRE

 

4

.64

.59

.56

.54

.59

.54

.57

.53

.56

.52

.51

 

0-30

2700

40.92

65.12

 

5

.61

.56

.53

.50

.55

.50

.54

.50

.53

.49

.48

 

0-40

3731

56.53

89.97

 

6

.58

.53

.50

.47

.52

.47

.51

.47

.51

.46

.45

 

0-60

4147

62.84

100

 

7

.55

.50

.46

.44

.49

.44

.49

.44

.48

.43

.42

 

0-90

4147

62.84

100

 

8

.53

.47

.43

.41

.46

.41

.46

.41

.45

.41

.40

 

40-90

416

6.3

10.03

 

 

 

9

.50

.44

.41

.38

.44

.38

.43

.38

.43

.38

.37

 

60-90

0

0

0

 

 

90-180

0

0

0

 

10

.47

.41

.38

.36

.41

.36

.41

.35

.40

.35

.34

 

0-180

4147

62.84

100

 

 

 

 

LUMINAIRE INPUT WATTS = 78

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

** EFFICIENCY = 62.8% ** SC = 0.9

CERTIFIED TEST REPORT NO. 2335FR, DATE: OCT 14, 2003 COMPUTED BY LSI PROGRAM **TEST-LITE**

Job Information

 

Type:

Lightolier a Genlyte Thomas Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504

Page 2
Image 2
Lightolier C6CS-C6T6VM specifications Candlepower Distribution, Wall RCR