Calculite® HID Adjustable Accent C6P38MHA
Page 1 of 2 | 6" Aperture, PAR38 Ceramic Metal Halide |
|
| |
15" (381mm) | ||
19 |
|
|
15" (381mm)
20" (508 mm) to 30" (762 mm)
(270 mm)
Top View
(Electronic Ballast)
20" (508 mm) to 30" (762 mm)
(270 mm)
Top View
(Magnetic Ballast)
Ceiling Cutout: 6 9/16" (167mm) Dia.
Reflector Trim |
|
| Lamp |
|
| |
C6P38MHA CLW | Specular Clear, White Painted Flange. | C6A70P38E1 | Electronic 120V | 70W | PAR38 | Ceramic MH |
CLP | Specular Clear, Matching Flange. | C6A70P38E2 | Electronic 277V | 70W | PAR38 | Ceramic MH |
CCDW | Comfort Clear Diffuse, White Painted Flange. | C6A10P38E1 | Electronic 120V | 100W | PAR38 | Ceramic MH |
CCDP | Comfort Clear Diffuse, Matching Flange. | C6A10P38E2 | Electronic 277V | 100W | PAR38 | Ceramic MH |
CCZW | Champagne Bronze, White Painted Flange. |
| Magnetic 120V/277V | 70W | PAR38 | Ceramic MH |
CCZP | Champagne Bronze, Matching Flange. |
| Magnetic 120V/277V | 100W | PAR38 | Ceramic MH |
|
|
|
|
|
|
|
Features
1.Reflector Trim: Low brightness, anodized aluminum or Comfort Clear™ with integral flange in painted white or polished to match inside of cone.
2.Lamp Holder Assembly: Unitized optics insure alignment of lamp and aper- ture cone. Integral
3.Trim Adjustment Mechanism: Provides 40° vertical tilt, 360° + horizontal rotation; lockable. Patented
4.Socket: Medium base porcelain socket with nickel plated screwshell.
5.Frame Housing: Steel, 0.029"
6.Frame Vertical Adjustment Mechanism: Accommodates mounting to virtually any ceiling system using
7.Mounting Bars: Galvanized steel, 0.048"
8.Retention Springs: Rust resistant springs secure trim for quick,
9.Ballast / Cover Assembly: Accessible from below and removable without tools for inspection and ballast replacement .
10.Junction Box: 0.059"
11.Thermal Protector: (Not Shown) Meets NEC and UL requirements. Do not install insulation above nor within 3" (76mm) of any part of the luminaire.
Electrical
Electronic Ballast: 120V or 277V, 50/60 Hz. Electronic, encased, high power factor, T.H.D. <15%, thermally and transient protected, RMI/RFI complies with FCC part 18
Electrical (Cont.)
Ballast | ANSI Code | Voltage | Max. Amps | Input Watts |
70W MH | M98/M143 | 120/277 | 0.67/0.28 | 78 |
100W MH | M90/M140 | 120/277 | 0.90/0.43 | 110 |
Magnetic Ballast: 120V/277V dual voltage, 60 Hz., encased and potted,
Ballast | ANSI Code | Voltage | Max. Amps | Input Watts |
70W MH | M98/M143 | 120/277 | 1.90/0.80 | 94 |
100W MH | M90/M140 | 120/277 | 2.40/1.10 | 125 |
Options and Accessories
Fuse (magnetic ballast): Add suffix F1 or F2 to
Labels:
UL (Suitable For Damp Locations), CSA (Magnetic Ballast only) I.B.E.W.
Job Information | Type: |
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier a Genlyte companywww.lightolier.com 631 Airport Road, Fall River, MA 02720 • (508)
© 2006 Genlyte Group LLC • C0406