Calculite® HID Adjustable Accent C6T6A-MHT6RNF

Page 1 of 2

6" Aperture, T6, Ceramic Metal Halide, Narrow Flood

19-1/8" 15"

20" to 30"

19-5/8"

10-5/8"

20-1/4" (Electronic)

22-1/8" (Magnetic)

Top View

Narrow Flood Upper Reflector

Ceiling Cutout: 6 9/16” (167mm) Dia.

For Complete Fixture Order: Trim Kit + Narrow Flood Upper Reflector (MHT6RNF) + Frame-In Kit. Each Sold Separately.

Trim Kit + Narrow Flood Upper Reflector

Frame-In Kit

Lamp

 

C6T6A

 

 

+ MHT6RNF (Narrow Flood Upper Reflector)

C6A39T6E1

Electronic 120V

39W T6

Ceramic MH

 

CLW

Specular Clear, White Painted Flange

C6A39T6E2

Electronic 277V

39W T6

Ceramic MH

C6A70T6E1

Electronic 120V

70W T6

Ceramic MH

CLP

Specular Clear, Matching Flange

CCDW

Comfort Clear Diffuse, White Painted Flange

C6A70T6E2

Electronic 277V

70W T6

Ceramic MH

CCDP

Comfort Clear Diffuse, Matching Flange

C6A15T6E1

Electronic 120V

150W T6

Ceramic MH

CCZW

Champagne Bronze, White Painted Flange

C6A15T6E2

Electronic 277V

150W T6

Ceramic MH

CCZP

Champagne Bronze, Matching Flange

 

Magnetic 120V/277V

150W T6

Ceramic MH

 

 

 

 

 

 

 

 

Features

1.Narrow Flood Upper Reflector: Specular split faceted aluminum; provides 25° beam. Interchangeable with 12° Spot (MHT6RS) and 40° Flood (MHT6RF); see spec sheets C6T6A-MHT6RS and C6T6A-MHT6RF.

2.Trim Kit: Low brightness aperture cone; anodized aluminum, self-flanged in painted white or aperture-matching polished flange. Consult factory for other finishes.

3.Lamp Shield: High-temperature glass as required by code; captive during re-lamping.

4.Trim Kit Adjustment Mechanism: Provides 40° vertical tilt, 360° horizon- tal rotation; lockable. Patented EZ-Aim Helical Drive System provides fast and accurate hot aiming with Philips screwdriver.

5.Socket Housing: Galvanized steel, pre-wired with G12 pulse rated socket. Snaps onto yoke for secure attachment without tools; unitized construction assures proper alignment of lamp to optics for consistent optical performance.

6.Frame Housing: Steel, 0.029" (22-Ga.), matte black finish. Removable cover for top re-lamping.

7.Frame Vertical Adjustment Mechanism: Accommodates mounting to virtually any ceiling system using pre-installed mounting bars, or 1/2" EMT tubing (by others). Single locking feature secures all adjustments. Alignment holes and markings allow fixture to be pre-set prior to installation. Final adjustment can be made from below from inside fixture.

8.Mounting Bars: Galvanized steel, 0.048" (18-ga.), pre-installed telescoping bars extend to 30" long and lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self-centering feature simplifies installation in 24" O.C. grid systems. Attaches to steel or wood joists without accessories.

9.Retention Springs: Rust resistant springs secure trim for quick, tool-less installation.

10.Ballast / Cover Assembly: Accessible from below and removable without tools for inspection and ballast replacement .

11.Junction Box: 0.059" (16-ga.) galvanized steel. UL listed for 8 No. 12 AWG, 90°C through branch circuit conductors. Allows inspection from below.

12.Accessory Holder: Sold separately catalog # CAH6; die-formed steel, matte black finish, slide-in installation. Accepts up to two 4 3/4" dia. media.

13.Thermal Protector: (Not Shown) Meets NEC and UL requirements. Do not install insulation above nor within 3" (76mm) of any part of the luminaire.

Electrical

Electronic Ballast: 120 or 277V, 50/60 Hz., encased, high power factor, T.H.D <15%, thermally and transient protected, RMI/RFI complies with FCC Part 18 on- consumer equipment, shut-down circuit at end of lamp life, sound rating “A”, - 5°F (-20°F for 150W) minimum starting temperature, Type 1 outdoor rating. *150W Magnetic Ballast: 120/277V dual voltage, 60 Hz., encased and potted, HX-HPF circuit type, high power factor, sound rating “B”, -20°F minimum starting temperature, Type 1 Outdoor rating.

Ballast

ANSI Code

Voltage

Max. Amps

Input Watts

39W MH

M130

120/277

0.39/0.17

44

70W MH

M139

120/277

0.67/0.28

78

150W

MH

M142

120/277

1.40/0.60

167

* 150W

MH

M142

120/277

3.70/1.60

180

Options and Accessories

Chicago Plenum: Consult Factory

Fuse (magnetic ballast): Add suffix F1 or F2 to Frame-In Kit (F1=120V, F2=277V)

Labels

UL (Suitable for Damp Locations), CSA, I.B.E.W.

For 150W, install fixtures with minimum spacing between:

1.

Center-to center of adjacent luminaries: 2 feet.

2.

Top of luminaire to overhead building member: 1/2 inch.

3.

Luminaire center to side building member: 1 foot.

Job Information

Type:

Job Name:

Cat. No.:

Lamp(s):

Notes:

Lightolier a Genlyte companywww.lightolier.com 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2006 Genlyte Group LLC • B0406

Page 1
Image 1
Lightolier C6T6A-MHT6RNF manual Trim Kit + Narrow Flood Upper Reflector Frame-In Kit Lamp, Features, Electrical, Labels