READ1 AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING ACCESSORY

This accessory is intended for installation in accordance with the National Electrical Code and local regulations. To assure full compliance with local codes and regulations, check with your local electrical inspector before installation. To prevent electric shock, turn off electricity at fuse box before proceeding.

Retain these instructions for maintenance reference.

INSTRUCTION SHEET NO.

IS:C6TCAA

A0502

 

Page 1 of 1

INSTALLATION PROCEDURE FOR C6TCAA CALCULITE EVOLUTION

6 INCH APERTURE THICK CEILING ADAPTER SPRINGS

CAUTION-TO AVOID OVERHEATING: DO NOT USE THIS PRODUCT WITH C6AIC, C6AICLV, or C6DAIC

FRAMES AND/OR C6P36A SERIES TRIMS WITH DATE CODE OF 2402 OR EARLIER. (2402 = WEEK 24, 2002)

FIG. 1

Installation Instructions:

C6TCAA

6” Aperture

Thick Ceiling Adapter (3 pieces required, kit contains one extra piece)

CAT.

LISTED

 

xxxxxxxxxxxxxxxxxxxxxxxxxxx

C6AI

XXX

xxxxxxxxxxxxxxxxxxxxxxxxxxx

 

xxxxxxxxxxxxxxxxxxxxxxxxxxx

xxxxxxxxxxxxxxxxxxxxxxxxxxx XXXX

xxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxx

UL-2577-R

DATE CODE LOCATION

1 . Measure distance between bottom surface of APERTURE RING (supplied with FIK) and CEILING, as shown in Fig. 2.

2 . Break ADAPTER SPRINGS in appropriate location, if required. See views in Fig. 2.

3 . Move RETENTION SPRING (supplied with trim) towards REFLECTOR BODY to expose SPRING POCKET (Fig. 3a, step 1). Insert ADAPTER SPRINGS into SPRING POCKETS as shown (Fig. 3a, step 2).

4 . Push down on ADAPTER SPRINGS until lowermost TABS lock firmly into place.

5 . Install reflector trim in the usual fashion. Refer to reflector trim instruction sheet for installation, wiring, and lamping information.

FIG. 2

APERTURE

RING

“X”

CEILING

FIG. 2a

“X” = 7/8” to 1-1/8” (UN-MODIFIED)

FIG. 2b

“X” = 5/8” to 7/8”

FIG. 2c “X” = 3/8” to 5/8”

 

RETENTION

FIG. 3a

 

SPRING

 

 

 

TABS

ADAPTER

1

SPRING POCKET

SPRING

2

REFLECTOR

BODY

FIG. 4

FIG. 3

REFLECTOR TRIM WITH ADAPTER

SPRINGS INSTALLED, READY FOR

INSTALLATION INTO LIGHTOLIER

FRAME-IN KIT.

A COMPANY