Lightolier specifications Page 2 of, Calculite HID Downlight C7E170VW, Job Information, Type

Models: C7E170VW

1 2
Download 2 pages 45.09 Kb
Page 2
Image 2
Calculite® HID Downlight C7E170VW

 

Calculite® HID Downlight C7E170VW

Page 2 of 2

7" Aperture, ED17 (Open Rated) Ceramic Metal Halide Wide Beam

70W ED17 PHILIPS CMH LAMP, LUMEN RATING = 5700 LMS, AROMAT ELECTRONIC BALLAST, CL FINISH REFLECTOR TRIM

625

1,250

1,875

2,500

 

ANGLE

MEAN CP

LUMENS

 

0

2368

 

 

5

2376

227

 

10

2383

 

 

15

2285

640

 

20

2084

 

 

25

1929

898

 

30

1820

 

60°

35

1795

1069

40

1397

 

 

 

 

45

592

510

 

50

51

 

 

55

10

17

 

60

5

 

 

65

2

2

 

70

0

 

 

75

0

0

 

80

0

 

 

85

0

0

 

90

0

 

30°

 

 

 

LUMINANCE SUMMARY - CD. / SQ. M.

 

 

 

 

Coefficients of Utilization

 

 

 

 

ANGLE

MEAN CD/SQ M

 

 

 

 

 

 

 

 

 

 

45

 

33868

CEILING

 

 

 

 

 

80%

 

 

70%

 

50%

 

30%

 

 

55

 

713

WALL

 

 

70

50

30

10

50

10

50

10

50

10

 

0

65

 

157

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75

 

0

RCR

 

 

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

 

85

 

0

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

.70

.70

.70

.70

.69

.69

.66

.66

.63

.63

 

.59

 

 

 

 

 

1

.67

.65

.64

.63

.64

.62

.62

.60

.60

.58

 

.55

ZONAL LUMENS AND PERCENTAGES

 

2

.64

.61

.59

.57

.60

.56

.58

.55

.57

.54

 

.52

ZONE LUMENS

% LAMP %LUMINAIRE

 

3

.61

.57

.54

.52

.56

.52

.55

.51

.53

.50

 

.48

0-30

1765

30.97

52.49

 

4

.58

.53

.50

.48

.53

.47

.52

.47

.50

.46

 

.45

0-40

2834

49.73

84.27

 

5

.55

.50

.46

.44

.49

.44

.48

.43

.47

.43

 

.42

0-60

3361

58.97

99.93

 

 

 

6

.52

.47

.43

.41

.46

.40

.45

.40

.44

.40

 

.39

0-90

3363

59.01

100

 

 

40-90

529

9.28

15.73

 

7

.49

.43

.40

.37

.43

.37

.42

.37

.41

.36

 

.35

60-90

2

0.04

0.07

 

8

.46

.40

.36

.34

.39

.34

.39

.34

.38

.33

 

.32

90-180

0

0

0

 

9

.43

.37

.33

.31

.37

.31

.36

.31

.36

.30

 

.29

0-180

3363

59.01

100

 

 

 

10

.40

.34

.30

.28

.34

.28

.33

.28

.33

.28

 

.27

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LUMINAIRE INPUT WATTS = 78.0

** EFFICIENCY = 59.0% **

SC = 1.2

CERTIFIED TEST REPORT NO. 2373FR, DATE: FEB 10, 2004 COMPUTED BY LSI PROGRAM **TEST-LITE**

100W ED17- PHILIPS CMH LAMP, LUMEN RATING = 8500 LMS, AROMAT ELECTRONIC BALLAST, CL FINISH REFLECTOR TRIM

875

1,750

2, 625

3,500

 

ANGLE

MEAN CP

LUMENS

 

0

3454

 

 

5

3405

327

 

10

3433

 

 

15

3401

948

 

20

3144

 

 

25

2867

1333

 

30

2639

 

60°

35

2600

1564

40

2121

 

 

 

 

45

924

784

 

50

78

 

 

55

9

22

 

60

1

 

 

65

0

0

 

70

0

 

 

75

0

0

 

80

0

 

 

85

0

0

 

90

0

 

30°

 

 

 

LUMINANCE SUMMARY - CD. / SQ. M.

 

 

 

Coefficients of Utilization

 

 

 

 

ANGLE

MEAN CD/SQ M

 

 

 

 

 

 

 

 

 

45

 

52847

CEILING

 

 

 

 

80%

 

 

70%

 

50%

 

30%

 

 

55

 

607

WALL

 

70

50

30

10

50

10

50

10

50

10

 

0

65

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RCR

 

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

 

75

 

0

 

 

85

 

0

 

 

0

.70

.70

.70

.70

.68

.68

.65

.65

.62

.62

 

.59

 

 

 

 

 

1

.67

.65

.64

.62

.64

.61

.61

.59

.59

.58

 

.55

 

 

 

 

 

ZONAL LUMENS AND PERCENTAGES

 

2

.63

.61

.59

.57

.60

.56

.58

.55

.56

.54

 

.52

ZONE LUMENS

% LAMP %LUMINAIRE

 

3

.60

.57

.54

.52

.56

.51

.54

.50

.53

.50

 

.48

0-30

2607

30.68

52.39

 

4

.57

.53

.50

.47

.52

.47

.51

.47

.50

.46

 

.45

0-40

4171

49.08

83.81

 

 

 

5

.54

.49

.46

.43

.49

.43

.48

.43

.47

.43

 

.41

0-60

4977

58.56

99.99

 

 

0-90

4977

58.56

100

 

6

.51

.46

.43

.40

.46

.40

.45

.40

.44

.39

 

.38

40-90

805

9.48

16.19

 

7

.48

.43

.39

.37

.42

.36

.42

.36

.41

.36

 

.35

60-90

0

0

0.01

 

8

.45

.40

.36

.34

.39

.33

.39

.33

.38

.33

 

.32

90-180

0

0

0

 

 

0-180

4977

58.56

100

 

9

.43

.37

.33

.30

.36

.30

.36

.30

.35

.30

 

.29

 

 

 

 

 

10

.40

.34

.30

.28

.33

.28

.33

.28

.33

.27

 

.27

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LUMINAIRE INPUT WATTS = 110

** EFFICIENCY = 58.6% **

SC = 1.1

CERTIFIED TEST REPORT NO. 2374FR, DATE: FEB 10, 2004 COMPUTED BY LSI PROGRAM **TEST-LITE**

150W ED17- PHILIPS CMH LAMP, LUMEN RATING = 11900 LMS, AROMAT ELECTRONIC BALLAST, CL FINISH REFLECTOR TRIM

1,250

2,500

3,750

5,000

 

ANGLE

MEAN CP

LUMENS

 

0

4841

 

 

5

4899

467

 

10

4947

 

 

15

4765

1336

 

20

4373

 

 

25

4003

1865

 

30

3737

 

 

35

3769

2257

60°

40

3096

1139

 

45

1336

 

50

116

 

 

55

21

37

 

60

9

 

 

65

2

3

 

70

0

 

 

75

0

0

 

80

0

 

 

85

0

0

 

90

0

 

30°

 

 

 

LUMINANCE SUMMARY - CD. / SQ. M.

 

 

 

Coefficients of Utilization

 

 

 

 

ANGLE

MEAN CD/SQ M

 

 

 

 

 

 

 

 

 

45

 

76396

CEILING

 

 

 

 

80%

 

 

70%

 

50%

 

30%

 

 

55

 

1479

WALL

 

70

50

30

10

50

10

50

10

50

10

 

0

65

 

193

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75

 

0

RCR

 

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

 

85

 

0

 

 

0

.71

.71

.71

.71

.69

.69

.66

.66

.64

.64

 

.60

 

 

 

 

 

1

.68

.66

.65

.63

.65

.62

.62

.61

.60

.59

 

.56

ZONAL LUMENS AND PERCENTAGES

 

 

2

.65

.62

.60

.58

.61

.57

.59

.56

.57

.55

 

.52

ZONE LUMENS

% LAMP %LUMINAIRE

 

3

.61

.58

.55

.52

.57

.52

.55

.51

.54

.50

 

.49

0-30

3668

30.83

51.63

 

 

 

4

.58

.54

.51

.48

.53

.48

.52

.47

.51

.47

 

.45

0-40

5925

49.79

83.4

 

 

0-60

7101

59.68

99.95

 

5

.55

.50

.47

.44

.50

.44

.48

.44

.48

.43

 

.42

0-90

7104

59.7

100

 

6

.52

.47

.43

.41

.46

.40

.45

.40

.45

.40

 

.39

40-90

1179

9.91

16.6

 

7

.49

.43

.40

.37

.43

.37

.42

.37

.41

.37

 

.36

60-90

3

0.03

0.05

 

 

 

8

.46

.40

.36

.34

.40

.34

.39

.34

.39

.33

 

.32

90-180

0

0

0

 

 

0-180

7104

59.7

100

 

9

.43

.37

.33

.31

.37

.31

.36

.31

.36

.30

 

.29

 

 

 

 

 

10

.40

.34 .30

.28

.34

.28

.33

.28

.33

.28

 

.27

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LUMINAIRE INPUT WATTS = 167

 

 

 

 

** EFFICIENCY = 59.7% **

SC = 1.2

CERTIFIED TEST REPORT NO. 2375FR, DATE: FEB 10, 2004 COMPUTED BY LSI PROGRAM **TEST-LITE**

Job Information

 

Type:

Lightolier a Genlyte Thomas Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504

Page 2
Image 2
Lightolier specifications Page 2 of, Calculite HID Downlight C7E170VW, Job Information, Type