Calculite® HID Downlight C7E17VM
Page 1 of 2
 20" (508 mm) to 30" (762 mm)
7" Aperture, ED17 (Enclosed), Ceramic Metal Halide, Medium Beam
  | ||
  | (210 mm)  | (248 mm)  | 
5/8" (473 mm)  | ||
18-  | 
  | 
  | 
Top View  | ||
(Magnetic Ballast)  | ||
(251 mm)  | ||
  | ||
20" (508 mm) to  | 
  | |
30" (762 mm)  | 
  | |
  | ||
(248 mm)  | 
  | |
  | ||
11" (280 mm)  | 
  | |
(100/150W)  | 
  | 
Top View
(Electronic Ballast)
Ceiling Cutout: 8" (203mm) Dia.
 
Flangless Trim with
Vertical Adjustment: 5/8" (16 mm) to
2 7/8" (73 mm)
2" (50 mm) max. 
 Ceiling Thickness
Reflector Trim  | 
  | 
 | Lamp (Coated, Ceramic MH) | ||
C7E17VM CLW  | Specular Clear, White Painted Flange.  | C770MHE1  | Electronic 120V  | 70W ED17, BD17 (Enclosed)  | |
CLP  | Specular Clear, Matching Flange.  | C770MHE2  | Electronic 277V  | 70W ED17, BD17 (Enclosed)  | |
CCDW  | Comfort Clear Diffuse, White Painted Flange.  | C710MHE1  | Electronic 120V  | 100W ED17, BD17 (Enclosed)  | |
CCDP  | Comfort Clear Diffuse, Matching Flange.  | C710MHE2  | Electronic 277V  | 100W ED17, BD17 (Enclosed)  | |
CCZW  | Champagne Bronze, White Painted Flange.  | C770MHU  | Magnetic 120V/277V  | 70W ED17, BD17 (Enclosed)  | |
CCZP  | Champagne Bronze, Matching Flange.  | C710MHU  | Magnetic 120V/277V  | 100W ED17, BD17 (Enclosed)  | |
  | 
  | 
  | 
  | 
  | 
  | 
Features
1.Reflector Trim: Clear anodized aluminum, 0.040” 
2.Lamp Guard: High heat resistant glass (as required by code).
3.Socket Cup: Galvanized steel, 
4.Mounting Ring: 0.048" 
5.Mounting Frame: 0.048" 
6.Retention Springs: Rust resistant springs secure reflector in place for quick, 
7.Frame Vertical Adjustment Mechanism: Vertical adjustment mechanism accommodates mounting to virtually any ceiling system using 
8.Mounting Bars: 0.048" 
9.Ballast: Electronic 120V or 277V. Magnetic dual voltage (120V & 277V). Accessible from below for inspection and/or replacement without tools.
10.Junction Box: 0.048" 
11.Thermal Protector: (Not Shown) Meets NEC and UL requirements. Do not install insulation above nor within 3" (76mm) of any part of the luminaire.
Electrical
Electronic Ballast: 120V or 277V, 50/60 Hz., encased, 
Electrical (cont)
Ballast | ANSI Code  | Voltage  | Max. Amps  | Input Watts  | 
70W MH  | M98/M143  | 120/277  | 0.67/0.28  | 78  | 
100W MH  | M90/M140  | 120/277 | 0.90/0.43 | 110 | 
Magnetic Ballast: 120/277V dual voltage, 60 Hz., encased and potted, 
temperature, Type 1 Outdoor rating.  | 
  | 
  | ||
Ballast  | ANSI Code  | Voltage  | Max. Amps  | Input Watts  | 
70W MH  | M98/143  | 120/277  | 1.90/0.80  | 94  | 
100W MH  | M90/140  | 120/277  | 2.40/1.10  | 125  | 
Options and Accessories
Auxiliary: Add suffix A to 
Emergency Lamp: Add suffix E to Reflector Trim and 
Slope Ceiling Adapters: See Specification Sheet SCA.
Fuse (magnetic ballast): Add suffix F1 or F2 to 
Chicago Plenum: Consult Factory.
Labels
UL (Suitable for Damp Locations), CSA (magnetic ballast only), I.B.E.W. For 100W electronic, install fixtures with minimum spacing: 2 feet from 
Job Information  | Type:  | 
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier a Genlyte Thomas Companywww.lightolier.com 631 Airport Road, Fall River, MA 02720 • (508) 
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504