Lighting Systems CD12-1
1BHFPG2$FOUSBM5SPVHI3FDFTTFE%JSFDU-PVWFS-JHIU51FS'PPU4FDUJPO
Performance & Quick Calculators |
|
|
|
|
|
| |||||
| CANDLEPOWER CURVE |
| ZONE | CANDLEPOWER SUMMARY | 90 | ||||||
180˚ 175˚ | 165˚ | 155˚ | 145˚ | 135˚ | 0 | 22 | 45 | 67 | |||
1500 |
|
|
|
|
| Deg |
|
|
|
|
|
|
|
|
|
| 125˚ | 180 | 0 | 0 | 0 | 0 | 0 |
1200 |
|
|
|
| 175 | 0 | 0 | 0 | 0 | 0 | |
|
|
|
|
|
| 165 | 0 | 0 | 0 | 0 | 0 |
900 |
|
|
|
| 115˚ | 155 | 0 | 0 | 0 | 0 | 0 |
|
|
|
|
| 145 | 0 | 0 | 0 | 0 | 0 | |
|
|
|
|
|
| ||||||
600 |
|
|
|
| 105˚ | 135 | 0 | 0 | 0 | 0 | 0 |
|
|
|
|
| 125 | 0 | 0 | 0 | 0 | 0 | |
300 |
|
|
|
| 95˚ | 115 | 0 | 0 | 0 | 0 | 0 |
|
|
|
|
| 105 | 0 | 0 | 0 | 0 | 0 | |
|
|
|
|
|
| ||||||
0 |
|
|
|
| 90˚ | 95 | 0 | 0 | 0 | 0 | 0 |
300 |
|
|
|
| 85˚ | 85 | 1 | 2 | 4 | 6 | 7 |
|
|
|
|
| 75 | 9 | 11 | 16 | 22 | 27 | |
|
|
|
|
|
| ||||||
600 |
|
|
|
| 75˚ | 65 | 27 | 34 | 52 | 89 | 99 |
| 0˚ |
|
|
| 55 | 134 | 206 | 223 | 246 | 239 | |
|
|
|
|
| 45 | 361 | 456 | 460 | 442 | 442 | |
900 |
|
|
|
| 65˚ | ||||||
|
|
|
| 35 | 511 | 572 | 639 | 666 | 589 | ||
|
|
|
|
| |||||||
1200 |
|
|
|
|
| 25 | 614 | 644 | 702 | 765 | 785 |
|
| 90˚ |
| 55˚ | 15 | 692 | 702 | 725 | 756 | 759 | |
|
|
|
| 5 | 723 | 722 | 729 | 727 | 728 | ||
1500 |
|
|
|
|
| ||||||
|
|
|
|
| 0 | 730 | 730 | 730 | 730 | 730 | |
0˚ | 5˚ | 15˚ | 25˚ | 35˚ | 45˚ |
|
|
|
|
|
|
REPORT NO: LRL |
| SPACING RATIO: PERPENDICULAR — 1.2 |
|
| |||||||
| ROOM SURFACE REFLECTANCES 80% CEILING 50% WALLS 20% FLOOR | ||||||||||
LAMPS: |
| ||||||||||
| 120 |
|
|
|
|
| |||||
LUMENS: 3150 |
|
|
|
| 3200 LUMENS PER LAMP |
| |||||
|
|
|
|
|
| ||||||
EFFICIENCY: 50.7% |
| 100 |
|
| RCR - 1(Rm width - 10xMtg Ht above work plane) | ||||||
|
|
| RCR - 5 (Rm width - 2xMtg Ht above work plane) | ||||||||
|
|
|
|
| FOOTCANDLES |
|
|
| RCR - 10 (Rm width - Mtg Ht above work plane) | ||
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
| 80 |
|
|
|
|
|
|
|
|
|
| INITIAL | 60 |
|
|
|
|
|
|
|
|
|
| 40 |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| 20 |
|
|
|
|
|
46810121416 CENTER TO CENTER SPACING OF FIXTURE ROWS IN FEET
FOR 2 LIGHT UNITS MULTIPLY CHART VALUES BY 2.0
Ordering Information
COEFFIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
|
|
|
| 80 |
|
| 70 |
|
| 50 |
|
|
|
|
|
| % WALL REFLECTANCE |
|
| ||||
|
|
| 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 |
RATIO | 1 | 55 | 53 | 52 | 54 | 52 | 51 | 52 | 51 | 50 | |
2 | 50 | 47 | 45 | 49 | 47 | 45 | 47 | 45 | 44 | ||
|
| 3 | 45 | 42 | 40 | 45 | 42 | 39 | 43 | 41 | 39 |
CAVITY | 4 | 41 | 38 | 35 | 41 | 37 | 35 | 39 | 37 | 34 | |
5 | 37 | 33 | 31 | 37 | 33 | 30 | 36 | 33 | 30 | ||
|
| 6 | 34 | 30 | 27 | 33 | 30 | 27 | 33 | 29 | 27 |
ROOM | 7 | 31 | 27 | 24 | 30 | 27 | 24 | 30 | 26 | 24 | |
9 | 25 | 21 | 18 | 24 | 21 | 18 | 24 | 21 | 18 | ||
|
| 8 | 28 | 24 | 21 | 27 | 24 | 21 | 27 | 23 | 21 |
|
| 10 | 23 | 19 | 16 | 22 | 19 | 16 | 22 | 18 | 16 |
|
|
|
|
|
|
|
|
|
|
|
|
| ZONAL LUMENS AND PERCENTAGES | ||
ZONE | LUMENS | % BARELAMP | %LUMINAIRE |
597 | 50.7 | 100.00 | |
0 | 0.0 | 0.0 | |
1597 | 50.7 | 100.00 |
One Lamp
Catalog Number | Lamps | Length | Function |
21" | Modular Unit | ||
33" | Modular Unit | ||
45" | Modular Unit | ||
90" | Modular Unit | ||
Telescoping Unit | |||
— | 12" | 90° Universal Corner | |
|
|
|
|
*Each run MUST include a Telescoping fixture as the CD12 end plates only ship as part of the Telescoping fixture.
Ordering Instructions
Continuous Rows:
1.Determine run length.
2.Determine lamp configuration (1 or 2 lamp).
3.Use Ordering Information Chart to find catalog numbers.
A.Each run ends with a TELESCOPING UNIT.
B.Starting with the longest MODULAR UNIT, fill in the remaining run.
Square/Rectangle Patterns:
1.Consult plans and mark locations of corners.
2.Calculate net footage of each linear run.
3.Deduct 12" for each corner.
4.Determine catalog numbers the same way as a STRAIGHT RUN.
Two Lamps
Catalog Number | Lamps | Length | Function |
24" | Modular Unit | ||
36" | Modular Unit | ||
48" | Modular Unit | ||
96" | Modular Unit | ||
Telescoping Unit | |||
— | 12" | 90° Universal Corner | |
|
|
|
|
NOTE: Add to end of catalog number for desired ballast. Blank = T12 Magnetic 120V
2 = T12 Magnetic 277V
E1 = T12 Electronic 120V
E2 = T12 Electronic 277V
E81 = T8 Electronic 120V
E82 = T8 Electronic 277V
M71 = T8 Electronic Dimming Ballast 120V
M72 = T8 Electronic Dimming Ballast 277V
HD1 = T8 PowerSpec® HDF Dimming 120V
HD2 = T8 PowerSpec® HDF Dimming 277V
Job Information | Type: |
"JSQPSU3PBE'BMM3JWFS."t t'BY
We reserve the right to change details of design, materials and finish.
XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt #