Lightolier CD5-1 1BHFPG2, Performance & Quick Calculators, Sample Run, Job Information, Type

Models: CD5-1

1 2
Download 2 pages 43.53 Kb
Page 2
Image 2
1BHFPG2

Lighting Systems CD5-1

1BHFPG2

-ZUFUVCF™%JSFDU*OEJSFDU-JHIU51FS'PPU4FDUJPO

Performance & Quick Calculators

180˚ 175˚

165˚

155˚

145˚

135˚

ZONE

0

CANDLEPOWER

90

 

 

 

 

COEFFICIENTS OF UTILIZATION

 

 

1200

 

 

 

 

22

45

67

% EFFECTIVE CEILING CAVITY REFLECTANCE

1000

 

 

 

125˚

DEG.

 

 

 

 

 

 

 

 

180

0

0

0

0

0

 

 

 

 

 

80

 

 

70

 

 

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

800

 

 

 

 

175

0

0

0

0

0

 

 

 

 

 

% WALL REFLECTANCE

 

 

 

600

 

 

 

115˚

165

0

0

0

0

0

 

 

 

 

50

30

10

50

30

10

50

30

10

 

 

 

 

 

155

0

0

0

0

0

 

 

 

 

 

 

 

 

 

 

 

 

0

 

78

78

78

77

77

77

73

73

73

 

400

 

 

 

105˚

145

0

0

0

0

0

 

RATIO

 

 

 

 

 

 

 

125

0

0

0

0

0

 

2

 

66

62

67

60

57

53

58

55

52

 

200

 

 

 

95˚

135

0

0

0

0

0

 

 

1

 

72

69

67

68

65

63

65

63

61

 

0

 

 

 

90˚

115

0

0

0

0

0

 

CAVITY

3

 

61

55

50

54

49

46

52

48

45

 

400

 

 

 

75˚

 

 

 

 

 

 

95

0

0

0

0

0

 

5

 

52

44

36

43

38

34

42

37

34

 

200

 

 

 

85˚

105

0

0

0

0

0

 

 

4

 

56

49

44

48

43

39

46

42

39

 

800

 

 

 

 

90

0

0

0

0

0

 

ROOM

6

 

48

40

34

39

34

30

38

33

30

 

 

 

 

 

75

95

137

138

116

106

 

8

 

41

33

27

32

27

23

31

27

73

 

600

 

 

 

65˚

85

19

22

19

20

20

 

 

7

 

44

36

30

36

30

26

34

30

26

 

 

 

 

 

 

 

 

 

1000

 

 

 

55˚

65

180

219

156

257

256

 

 

9

 

38

30

24

29

24

21

29

24

21

 

 

 

 

55

289

308

368

410

409

 

 

10

 

35

26

21

26

21

17

25

20

17

 

1200

 

 

 

 

45

372

441

427

468

478

 

 

 

 

 

 

 

 

35

464

590

504

511

532

 

 

 

 

ZONAL LUMEN SUMMARY

 

 

0˚ 5˚

15˚

25˚

35˚

45˚

ZONE

 

 

 

 

REPORT NO: LRL 799-1A

25

531

626

670

603

586

 

LUMENS

% BARELAMP % LUMINAIRE

15

575

317

672

718

716

0-90

 

1911

 

 

 

65.9

 

 

100

LAMPS: 1-32WT8

 

5

589

597

602

611

614

 

 

 

 

 

 

LUMENS: 2900

 

 

0

590

590

590

590

590

90-180

 

 

0

 

 

 

0

 

 

0

 

 

 

 

 

 

 

 

 

 

 

0-180

 

1911

 

 

 

65.9

 

 

100

DIRECT

 

 

SPACING RATIOS: PARALLEL - 1.3/PERPENDICULAR = 1.2

 

 

 

 

 

 

 

 

ROOM SURFACE REFLECTANCES: 80% CEILING, 50% WALLS, 20% FLOOR

 

 

 

 

 

120

 

 

 

 

 

 

3200 LUMENS PER LAMP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FOOTCANDLES

100

 

 

 

 

 

 

RCR = 1 (Rm. Width = 10xMtg. Ht. above work plane)

 

 

 

 

 

 

 

 

RCR = 5 (Rm. Width = 2xMtg. Ht. above work plane)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RCR = 10 (Rm. Width = Mtg. Ht. above work plane)

 

 

 

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INITIAL

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

20

30

40

50

60

70

80

90

 

 

 

 

 

 

 

 

 

AREA PER FIXTURE IN SQUARE FEET

 

 

 

 

 

 

 

 

 

 

3

4

5

 

 

6

 

7

 

 

 

8

 

6

 

 

CENTER TO CENTER DISTANCE OF FIXTURES IN FEET

180˚ 175˚

165˚

155˚

145˚

135˚

ZONE

0

CANDLEPOWER

67

1200

 

 

 

 

 

22

45

1000

 

 

 

 

125˚

DEG.

 

 

 

 

 

 

 

 

180

614

614

614

614

800

 

 

 

 

 

 

 

 

 

115˚

175

613

621

626

635

600

 

 

 

 

165

598

642

699

747

 

 

 

 

 

 

 

 

 

 

 

155

552

651

697

627

400

 

 

 

 

105˚

145

483

614

524

531

200

 

 

 

 

95˚

135

387

459

444

487

0

 

 

 

 

90˚

125

301

320

383

416

 

 

 

 

115

187

228

266

267

200

 

 

 

 

85˚

 

 

 

 

105

99

142

144

121

400

 

 

 

 

75˚

95

20

23

20

21

600

 

 

 

 

 

90

0

0

0

0

 

 

 

 

65˚

85

0

0

0

0

800

 

 

 

 

 

75

0

0

0

0

1000

 

 

 

 

55˚

65

0

0

0

0

 

 

 

 

55

0

0

0

0

1200

 

 

 

 

 

45

0

0

0

0

15˚

25˚

35˚

45˚

35

0

0

0

0

REPORT NO: LRL 799-1B

25

0

0

0

0

15

0

0

0

0

LAMPS: 1-32WT8

 

 

5

0

0

0

0

LUMENS: 2900

 

 

0

0

0

0

0

EFFICIENCY: 68.5%

90

 

COEFFICIENTS OF UTILIZATION

614

% EFFECTIVE CEILING CAVITY REFLECTANCE

639

80

70

 

50

 

745

 

% WALL REFLECTANCE

 

 

60950 30 10 50 30 10 50 30 10

497

RATIO

0

65

65

65

56

56

56

38

38

38

266

2

49

46

42

46

39

37

29

27

26

425

 

1

57

54

52

51

46

45

33

32

31

110

CAVITY

3

43

39

35

42

33

31

26

23

21

0

5

34

29

25

35

25

22

20

17

15

21

 

4

38

33

29

38

29

26

22

20

18

0

ROOM

6

30

25

21

32

22

18

18

15

13

0

8

24

19

16

27

17

14

14

12

10

0

 

7

27

22

18

29

19

16

16

13

11

0

 

9

22

17

14

25

15

12

13

10

9

0

 

10

20

15

12

23

13

11

12

9

8

0

 

 

 

 

 

 

 

 

 

 

 

0ZONAL LUMEN SUMMARY

0ZONE LUMENS % BARELAMP % LUMINAIRE

0

0-90

0

0

0

0

90-180

1987

68.5

100

 

 

0-180

1987

68.5

100

INDIRECT

 

 

SPACING RATIOS: 1.5/RECOMMENDED MIN. MOUNT FROM CEILING 18

 

 

 

 

ROOM SURFACE REFLECTANCES: 80% CEILING, 50% WALLS, 20% FLOOR

 

 

 

 

 

120

 

 

 

 

3200 LUMENS PER LAMP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FOOTCANDLES

100

 

 

 

 

RCR = 1 (Rm. Width = 10xMtg. Ht. above work plane)

 

 

 

 

RCR = 5 (Rm. Width = 2xMtg. Ht. above work plane)

 

 

 

 

 

 

 

 

 

 

 

RCR = 10 (Rm. Width = Mtg. Ht. above work plane)

 

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INITIAL

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

20

30

40

50

60

70

 

 

 

 

 

 

 

 

AREA PER FIXTURE IN SQUARE FEET

 

 

 

 

 

 

 

 

3

4

5

 

 

6

 

7

 

 

 

8

 

CENTER TO CENTER DISTANCE OF FIXTURES IN FEET

Sample Run

 

 

 

 

 

 

 

 

63-1/8" (160.34cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 Foot

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8 Foot

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

62" (157.48cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

64-1/4" (163.20cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

111-1/8" (282.26cm)

110" (279.40cm)

112-1/4" (285.12cm)

 

 

 

 

 

 

24"

 

1'

14fc

20fc

14fc

18"

45°

 

 

 

 

 

CEILING

2'

46fc

58fc

46fc

 

 

3'

40fc

20fc

40fc

 

 

FROM

4'

25fc

37fc

25fc

 

 

Fixture Lengths & Mounting Locations

63-1/8"

111-1/8" (282.26cm)111-1/8" (282.26cm)

(160.34cm)

1-1/8" (2.86cm)

23' 10-1/2" (727.71cm)

Louver, Lens and Joiner Block Accessories

DISTANCE

5'

 

13fc

19fc

13fc

 

6'

 

9fc

12fc

9fc

 

 

 

7'

 

6fc

8fc

6fc

 

 

CD5LV

CD5PLA

4' Black Louver

4' Prismatic Lens

Job Information

Type:

"JSQPSU3PBE'BMM3JWFS."t  t'BY  

We reserve the right to change details of design, materials and finish.

XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt C

Page 2
Image 2
Lightolier CD5-1 1BHFPG2, Performance & Quick Calculators, Sample Run, Fixture Lengths & Mounting Locations, Type