| Coffaire Drop Basket Surface CDB2SPF217 or 317 |
Page 2 of 2 | Direct/Indirect Surface Mounted Fluorescent – 2' x 2' with Perforated Basket |
| Static, 1, 2 or 3 Lamp T8 |
Model No. CDB2SPF217UNVHI
LER = FP - 46.6 IW - 30.8 BF - 0.88 Comparative yearly lighting energy cost per
1000 lumens = $5.15
Report Number: G2007131A
Catalog Number: CDB2SPF217UNVHI
Lamps: (2) F17T8
Luminaire: Coffaire Drop Basket
Ballast: QTP2X17T8/UNV ISN SC
Report is based on 1375 Lumens per lamp. Efficiency: 69.4%
CIE |
|
|
|
| |||||
Plane: |
|
|
|
|
| ||||
Spacing Criteria: |
|
| 1.2 |
|
| 1.3 | |||
Shielding Angles: |
|
| 90 |
|
| 90 | |||
Plane: |
|
|
|
|
| ||||
Luminous Length: |
| 23.040 |
| 23.040 | |||||
COEFFICIENTS OF UTILIZATION – |
|
| |||||||
ZONAL CAVITY METHOD. EFFECTIVE |
| ||||||||
FLOOR CAVITY REFLECTANCE 0.200 |
| ||||||||
RC |
| 80 |
|
| 50 |
|
| 30 |
|
RW | 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 |
01 | 62 | 60 | 57 | 56 | 54 | 52 | 54 | 52 | 50 |
02 | 57 | 52 | 47 | 48 | 45 | 42 | 46 | 43 | 41 |
03 | 52 | 45 | 40 | 42 | 38 | 34 | 40 | 37 | 34 |
04 | 47 | 40 | 34 | 37 | 33 | 29 | 36 | 32 | 29 |
05 | 43 | 35 | 30 | 33 | 28 | 25 | 32 | 28 | 25 |
06 | 40 | 32 | 26 | 30 | 25 | 22 | 29 | 25 | 21 |
07 | 37 | 29 | 23 | 27 | 23 | 19 | 26 | 22 | 19 |
08 | 34 | 26 | 21 | 25 | 20 | 17 | 24 | 20 | 17 |
09 | 32 | 24 | 19 | 23 | 18 | 15 | 22 | 18 | 15 |
10 | 30 | 22 | 17 | 21 | 17 | 14 | 21 | 17 | 14 |
CANDELA DISTRIBUTION
| 0.0 | 45.0 | 90.0 | FLUX |
0 | 506 | 506 | 506 |
|
5 | 503 | 504 | 504 | 48 |
15 | 478 | 484 | 491 | 137 |
25 | 431 | 448 | 467 | 207 |
35 | 368 | 400 | 432 | 251 |
45 | 294 | 344 | 390 | 265 |
55 | 210 | 285 | 343 | 251 |
65 | 130 | 227 | 292 | 217 |
75 | 69 | 169 | 231 | 168 |
85 | 18 | 91 | 135 | 89 |
90 | 2 | 31 | 59 |
|
|
|
|
|
|
ZONAL LUMEN SUMMARY
ZONE | LUMENS | % LAMP | % FIXT |
392 | 14.2 | 24.0 | |
642 | 23.4 | 39.3 | |
1158 | 42.1 | 70.9 | |
1633 | 59.4 | 100.0 | |
0000 | 0.0 | 000.0 | |
1633 | 59.4 | 100.0 | |
LUMINANCE DATA IN CANDELA/SQ. METER | |||
AVERAGE AVERAGE AVERAGE AVERAGE | |||
IN DEG. | |||
45 | 1054. | 1280. | 1451. |
55 | 924. | 1254. | 1510. |
65 | 727. | 1270. | 1634. |
75 | 553. | 1353. | 1850. |
85 | 268. | 1354. | 2009. |
Model No. CDB2SPF317UNVH3
LER = FP - 42.6 IW - 43.9 BF - 0.88 Comparative yearly lighting energy cost per
1000 lumens = $5.63
Report Number: G2007133A
Catalog Number: CDB2SPF317UNVH3
Lamps: (3) F17T8
Luminaire: Coffaire Drop Basket
Ballast: QTP3X17T8/UNV ISN SC
Report is based on 1375 Lumens per lamp. Efficiency: 55.5%
CIE |
|
|
|
| |||||
Plane: |
|
|
|
|
| ||||
Spacing Criteria: |
|
| 1.2 |
|
| 1.3 | |||
Shielding Angles: |
|
| 90 |
|
| 90 | |||
Plane: |
|
|
|
|
| ||||
Luminous Length: |
| 23.040 |
| 23.040 | |||||
COEFFICIENTS OF UTILIZATION – |
|
| |||||||
ZONAL CAVITY METHOD. EFFECTIVE |
| ||||||||
FLOOR CAVITY REFLECTANCE 0.200 |
| ||||||||
RC |
| 80 |
|
| 50 |
|
| 30 |
|
RW | 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 |
01 | 59 | 56 | 53 | 53 | 50 | 49 | 50 | 49 | 47 |
02 | 54 | 48 | 44 | 45 | 42 | 39 | 43 | 41 | 38 |
03 | 49 | 42 | 37 | 40 | 36 | 32 | 38 | 35 | 32 |
04 | 44 | 37 | 32 | 35 | 31 | 27 | 34 | 30 | 27 |
05 | 41 | 33 | 28 | 31 | 27 | 24 | 30 | 26 | 23 |
06 | 38 | 30 | 25 | 28 | 24 | 21 | 27 | 23 | 20 |
07 | 35 | 27 | 22 | 26 | 21 | 18 | 25 | 21 | 18 |
08 | 32 | 25 | 20 | 23 | 19 | 16 | 23 | 19 | 16 |
09 | 30 | 23 | 18 | 22 | 17 | 15 | 21 | 17 | 15 |
10 | 28 | 21 | 16 | 20 | 16 | 13 | 19 | 16 | 13 |
CANDELA DISTRIBUTION
| 0.0 | 45.0 | 90.0 | FLUX |
0 | 731 | 731 | 731 |
|
5 | 726 | 727 | 729 | 69 |
15 | 688 | 698 | 708 | 197 |
25 | 621 | 644 | 669 | 297 |
35 | 530 | 573 | 616 | 359 |
45 | 419 | 489 | 552 | 376 |
55 | 298 | 400 | 479 | 353 |
65 | 180 | 313 | 399 | 299 |
75 | 93 | 226 | 307 | 224 |
85 | 23 | 117 | 174 | 116 |
90 | 3 | 40 | 75 |
|
|
|
|
|
|
ZONAL LUMEN SUMMARY
ZONE | LUMENS | % LAMP | % FIXT |
564 | 13.7 | 24.6 | |
922 | 22.4 | 40.3 | |
1651 | 40.0 | 72.1 | |
2290 | 55.5 | 100.0 | |
0000 | 0.0 | 000.0 | |
2290 | 55.5 | 100.0 |
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE IN DEG.
45 1559. 1820. 2054.
55 1312. 1761. 2108.
65 1007. 1751. 2232.
75 745. 1810. 2459.
85 342. 1741. 2590.
Ordering Information
Explanation of Catalog Number. Example: CDB2SPF217UNVHI
| CD |
| B |
| 2 |
| S |
| P | |||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Coffaire Drop | Body Style: | Fixture | Ceiling | Type: | Perforated | |||||||||
| Basket | B = Surface | Width |
| Surface | Lamp | ||||||||
Direct/Indirect | Mounted |
|
|
|
|
|
| Shield | ||||||
| Recessed |
|
|
|
|
|
|
|
|
|
|
|
F
Flat White
Reflector
|
|
| 17 | |
|
|
|
| |
Lamp | Lamp: | |||
Quantity | (By Others) | |||
1=1 Lamp | 17 =T8 17W | |||
2=2 Lamp | (Nominal 24") | |||
3=3 Lamp |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Voltage: |
|
| Options: | |||||
120, 277 or |
| Add appropriate | ||||||
| suffix to catalog | |||||||
|
|
|
|
|
| no., ie: (A) |
Ballast Type:
| <20THD | <10THD |
1 or 2 Lamp Elec. T8 | SO* | HI* |
O3* | H3* | |
LOL Dimming T8 | PS* | – |
*Instant Start Standard
Other dimming options. Consult factory.
NOTE:
For T8 UNV, you must use HI OR H3 Ballast Code.
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: A. Internal slow blow fusing: SUFFIX: C.
Electrical Wiring Options: Emergency Packs are only avalable for remote mounting. Consult factory.
For motion or light sensor: See Folio OA20-10.
Specifications
Performance: In an installation of 2 lamp 17W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .60. To reduce glare the average brightness at 65° shall not exceed 1634 candelas per square meter. To control veiling reflections, luminaire output in the
Materials: Chassis parts are
Lamp Shield: 22 gauge steel perforated mesh lamp shield with white acrylic overlay.
Specifications (continued)
Finish: Chassis exterior – Soft white post painted polyester powder. Cavity – Soft white post painted polyester powder. Rust preventative undercoating. Reflector – Soft white post painted polyester powder.el.
Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W./UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Job Information Type:
For Factory Technical Information: (978)
631 Airport Road, Fall River, MA 02720 • (508)
www.lightolier.com © 2008 a Philips Group | Section 5/Folio |
Lightolier is a Philips group brand