| Coffaire Drop Basket Surface CDB2SPF232 or 332 |
Page 2 of 2 | Direct/Indirect Surface Mounted Fluorescent – 2' x 4' with Perforated Basket |
| Static, 1, 2 or 3 Lamp T8 |
Model No. CDB2SPF232UNVHI
LER = FP - 64.7 IW - 50.4 BF - 0.88 Comparative yearly lighting energy cost per
1000 lumens = $3.71
Report Number: G2007114A
Catalog Number: CDB2SPF232UNVHI
Lamps: (2) F28T8
Luminaire: Coffaire Drop Basket
Ballast: QTP2X32T8/UNV ISN SC
Report is based on 2725 Lumens per lamp. Efficiency: 68.0%
CIE |
|
|
|
| |||||
Plane: |
|
|
|
|
| ||||
Spacing Criteria: |
|
| 1.2 |
|
| 1.3 | |||
Shielding Angles: |
|
| 90 |
|
| 90 | |||
Plane: |
|
|
|
|
| ||||
Luminous Length: |
| 47.880 |
| 23.400 | |||||
COEFFICIENTS OF UTILIZATION – |
|
| |||||||
ZONAL CAVITY METHOD. EFFECTIVE |
| ||||||||
FLOOR CAVITY REFLECTANCE 0.200 |
| ||||||||
RC |
| 80 |
|
| 50 |
|
| 30 |
|
RW | 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 |
01 | 72 | 69 | 65 | 64 | 61 | 59 | 61 | 59 | 57 |
02 | 65 | 59 | 54 | 55 | 51 | 47 | 53 | 49 | 46 |
03 | 59 | 51 | 45 | 48 | 43 | 39 | 46 | 42 | 38 |
04 | 54 | 45 | 39 | 42 | 37 | 33 | 41 | 36 | 32 |
05 | 50 | 40 | 34 | 38 | 32 | 28 | 36 | 32 | 28 |
06 | 46 | 36 | 30 | 34 | 29 | 25 | 33 | 28 | 24 |
07 | 42 | 33 | 26 | 31 | 26 | 22 | 30 | 25 | 22 |
08 | 39 | 30 | 24 | 28 | 23 | 19 | 27 | 23 | 19 |
09 | 37 | 27 | 21 | 26 | 21 | 17 | 25 | 21 | 17 |
10 | 34 | 25 | 20 | 24 | 19 | 16 | 23 | 19 | 16 |
CANDELA DISTRIBUTION
| 0.0 | 45.0 | 90.0 | FLUX |
0 | 1128 | 1128 | 1128 |
|
5 | 1121 | 1122 | 1124 | 107 |
15 | 1068 | 1081 | 1094 | 305 |
25 | 970 | 1005 | 1041 | 463 |
35 | 834 | 902 | 968 | 565 |
45 | 668 | 784 | 878 | 601 |
55 | 481 | 658 | 776 | 576 |
65 | 297 | 532 | 657 | 502 |
75 | 149 | 400 | 505 | 388 |
85 | 36 | 203 | 283 | 200 |
90 | 5 | 65 | 125 |
|
|
|
|
|
|
ZONAL LUMEN SUMMARY
ZONE | LUMENS | % LAMP | % FIXT |
876 | 16.1 | 23.6 | |
1440 | 26.4 | 38.8 | |
2618 | 48.0 | 70.6 | |
3708 | 68.0 | 100.0 | |
0000 | 0.0 | 000.0 | |
3708 | 68.0 | 100.0 |
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. | |||
45 | 1241. | 1420. | 1550. |
55 | 1079. | 1424. | 1622. |
65 | 873. | 1486. | 1747. |
75 | 665. | 1645. | 1925. |
85 | 357. | 1681. | 2013. |
Model No. CDB2SPF332UNVH3
LER = FP - 38.9 IW - 122.0 BF - 0.88 Comparative yearly lighting energy cost per
1000 lumens = $6.17
Report Number: G2007116A
Catalog Number: CDB2SPF332UNVH3
Lamps: (3) F28T8
Luminaire: Coffaire Drop Basket
Ballast: QTP3X32T8/UNV ISN SC
Report is based on 2725 Lumens per lamp. Efficiency: 66.0%
CIE |
|
|
|
| |||||
Plane: |
|
|
|
|
| ||||
Spacing Criteria: |
|
| 1.2 |
|
| 1.3 | |||
Shielding Angles: |
|
| 90 |
|
| 90 | |||
Plane: |
|
|
|
|
| ||||
Luminous Length: |
| 47.880 |
| 23.400 | |||||
COEFFICIENTS OF UTILIZATION – |
|
| |||||||
ZONAL CAVITY METHOD. EFFECTIVE |
| ||||||||
FLOOR CAVITY REFLECTANCE 0.200 |
| ||||||||
RC |
| 80 |
|
| 50 |
|
| 30 |
|
RW | 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 |
01 | 71 | 67 | 64 | 63 | 60 | 58 | 60 | 58 | 56 |
02 | 64 | 58 | 53 | 54 | 50 | 47 | 52 | 48 | 46 |
03 | 58 | 50 | 44 | 47 | 42 | 39 | 45 | 41 | 38 |
04 | 53 | 44 | 38 | 42 | 37 | 33 | 40 | 36 | 32 |
05 | 48 | 39 | 33 | 37 | 32 | 28 | 36 | 31 | 28 |
06 | 45 | 35 | 29 | 34 | 28 | 24 | 32 | 28 | 24 |
07 | 41 | 32 | 26 | 30 | 25 | 22 | 29 | 25 | 21 |
08 | 39 | 29 | 23 | 28 | 23 | 19 | 27 | 22 | 19 |
09 | 36 | 27 | 21 | 26 | 21 | 17 | 25 | 20 | 17 |
10 | 34 | 25 | 19 | 24 | 19 | 16 | 23 | 19 | 16 |
CANDELA DISTRIBUTION
| 0.0 | 45.0 | 90.0 | FLUX |
0 | 1706 | 1706 | 1706 |
|
5 | 1695 | 1696 | 1698 | 161 |
15 | 1612 | 1628 | 1648 | 460 |
25 | 1460 | 1508 | 1559 | 696 |
35 | 1253 | 1345 | 1435 | 842 |
45 | 999 | 1155 | 1284 | 886 |
55 | 716 | 952 | 1113 | 837 |
65 | 435 | 755 | 925 | 715 |
75 | 215 | 551 | 687 | 535 |
85 | 50 | 267 | 375 | 267 |
90 | 7 | 83 | 165 |
|
|
|
|
|
|
ZONAL LUMEN SUMMARY
ZONE | LUMENS | % LAMP | % FIXT |
1317 | 16.1 | 24.4 | |
2159 | 26.4 | 40.0 | |
3883 | 47.5 | 71.9 | |
5399 | 66.0 | 100.0 | |
0000 | 0.0 | 000.0 | |
5399 | 66.0 | 100.0 |
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. | |||
45 | 1856. | 2091. | 2267. |
55 | 1606. | 2060. | 2326. |
65 | 1279. | 2108. | 2459. |
75 | 960. | 2266. | 2618. |
85 | 495. | 2211. | 2667. |
Ordering Information
Explanation of Catalog Number. Example: CDB2SPF232UNVHI
| CD |
| B |
| 2 |
| S |
| P | |||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Coffaire Drop | Body Style: | Fixture | Ceiling | Type: | Perforated | |||||||||
| Basket | B = Suface | Width |
| Surface | Lamp | ||||||||
Direct/Indirect | Mounted |
|
|
|
|
|
| Shield | ||||||
| Recessed |
|
|
|
|
|
|
|
|
|
|
|
F
Flat White
Reflector
|
|
| 32 | |
|
|
|
| |
Lamp | Lamp: | |||
Quantity | (By Others) | |||
1=1 Lamp | 32=T8 32W | |||
2=2 Lamp | (Nominal 48") | |||
3=3 Lamp |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Voltage: |
|
| Options: | |||||
120, 277 or |
| Add appropriate | ||||||
| suffix to catalog | |||||||
|
|
|
|
|
| no., ie: (A) |
Ballast Type:
<20THD <10THD
1 or 2 Lamp Elec. T8 SO* | HI* | |
O3* | H3* | |
LOL Dimming T8 | PS* | – |
*Instant Start Standard
Other dimming options. Consult factory.
NOTE:
For T8 UNV, you must use HI OR H3 Ballast Code.
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: A.
Internal slow blow fusing: SUFFIX: C.
Electrical Wiring Options: Consult factory.
For motion or light sensor: See Folio OA20-10.
Specifications
Performance: In an installation of 2 lamp 32W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .69. To reduce glare the average brightness at 65° shall not exceed 1747 candelas per square meter. To control veiling reflections, luminaire output in the
Materials: Chassis parts are
Lamp Shield: 22 gauge steel perforated mesh lamp shield with white acrylic overlay.
Specifications (continued)
Finish: Chassis exterior – Soft white post painted polyester powder. Cavity – Soft white post painted polyester powder. Rust preventative undercoating. Reflector – Soft white post painted polyester powder.
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations.
Labels: I.B.E.W./UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Job Information Type:
For Factory Technical Information: (978)
631 Airport Road, Fall River, MA 02720 • (508)
www.lightolier.com © 2008 a Philips Group | Section 5/Folio |
Lightolier is a Philips group brand