Lightolier CDS2GPF2FT Page 2 of, Direct/Indirect - 2 x 2 with Perforated Basket, Specifications

Models: CDS2GPF2FT

1 2
Download 2 pages 21.19 Kb
Page 2
Image 2
Page 2 of 2

Coffaire Drop Basket Recessed Fluorescent CDS2GPF2FT

Page 2 of 2

Model No. CDS2GPF2FTUNVPR

LER = FP - 45.0 IW - 69.3 BF - 0.90 Comparative yearly lighting energy cost per

1000 lumens = $5.34

Report Number: G2007138

Catalog Number: CDS2GPF2FTUNVPR

Lamps: (2) F40 TT5

Luminaire: Coffaire Drop Basket

Ballast: C240PUNVHP-B

Report is based on 3150 Lumens per lamp. Efficiency: 55.0%

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.2

 

 

1.3

Shielding Angles:

 

 

90

 

 

90

Plane:

 

 

 

 

0-Deg

 

90-Deg

Luminous Length:

 

23.040

 

23.040

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.200

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

01

59

56

53

52

50

48

50

48

47

02

53

48

44

45

42

39

43

40

38

03

48

42

37

39

35

32

38

34

31

04

44

37

32

35

30

27

33

30

27

05

40

33

28

31

27

23

30

26

23

06

37

29

24

28

24

20

27

23

20

07

34

27

22

25

21

18

24

21

18

08

32

24

19

23

19

16

22

19

16

09

30

22

18

21

17

14

21

17

14

10

28

21

16

20

16

13

19

15

13

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG. 45-DEG. 90-DEG.

45

2623.

2750.

3114.

55

1963.

2694.

3235.

65

1527.

2719.

3474.

75

1129.

2875.

3796.

85

476.

2560.

3751.

Direct/Indirect – 2' x 2' with Perforated Basket

Static, 2 Lamp Twin Tube T5

CANDELA DISTRIBUTION

 

0.0

45.0

90.0

FLUX

0

1088

1088

1088

 

5

1078

1081

1084

103

15

1020

1038

1053

293

25

921

960

999

443

35

788

857

926

537

45

625

739

837

568

55

446

612

735

538

65

273

486

621

462

75

141

359

474

350

85

32

172

252

173

90

4

58

111

 

 

 

 

 

 

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

00-030

839

13.3

24.2

00-040

1376

21.8

39.7

00-060

2482

39.4

71.6

00-090

3468

55.0

100.0

90-180

0000

0.0

000.0

00-180

3468

55.0

100.0

Ordering Information

Explanation of Catalog Number. Example: CDS2GPF2FTUNVPR

 

CD

 

S

 

2

 

G

 

P

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Coffaire Drop

 

Body Style:

 

Fixture

Ceiling

Type:

Perforated

 

Basket

 

S = Static

 

Width

 

Fits both

Lamp

Direct/Indirect

 

 

 

 

 

 

 

Standard Grid

Shield

 

Recessed

 

 

 

 

 

 

 

and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Slot Grid

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CD

 

Standard Coffaire Drop Basket

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YD

 

 

For NYC Code – Local 3 Manufactured

 

 

 

 

 

 

F

Flat White

Reflector

 

 

 

FT

 

 

 

 

 

 

Lamp

 

Lamp:

Quantity

 

(By Others)

2=2 Lamp

FT=Twin Tube T5

 

 

 

(Nominal 24")

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage:

 

 

 

Options:

120, 277 or

 

Add appropriate

UNV=120-277

 

suffix to catalog

 

 

 

 

 

 

 

no., ie: (GLR)

 

 

 

Ballast Type:

 

 

 

 

 

 

 

 

<20THD <10THD

1 or 2 Lamp Elec. TT5

SB*

IB**

 

(40 Watt)

PR†

1 or 2 Lamp Elec. TT5

 

(40 Watt)

PB

 

LOL Dimming TT5

 

*Instant Start Standard.

 

 

 

 

 

Other dimming options. Consult factory.

NOTE:

For TT5 40W UNV, you must use PR Ballast Code. †Program Rapid Start

Options/Accessories

Fusing: Internal fast blow fusing: SUFFIX: GLR.

Internal slow blow fusing: SUFFIX: GMF.

Drywall Kit: Order Catalog Number: FK92X2.

Electrical Wiring Options: Consult factory.For motion or light sensor: See Folio OA20-10.

Specifications

Performance: In an installation of 2 lamp 40W luminaire in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .56. To reduce glare the average brightness at 65° shall not exceed 3473 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 75.8%.

Materials: Chassis parts are die-formed code gauge steel.

Lamp Shield: 22 gauge steel perforated mesh lamp shield with white acrylic overlay.

Finish: Chassis exterior – soft white post painted polyester powder. Cavity – soft white post painted polyester powder. Reflector – soft white post painted polyester powder, minimum 88% reflectance. Rust preventive undercoating. Lamp Shield – soft white post painted polyester powder.

Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

Labels: I.B.E.W./UL and ULc Listed.

This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org

Job Information

Type:

 

 

Lightolier a Genlyte company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595