Lightolier CFA2GPF217 or 317 Page 2 of, Ordering Information, Options/Accessories, Specifications

Models: CFA2GPF217 or 317

1 2
Download 2 pages 60.65 Kb
Page 2
Image 2
Page 2 of 2

Coffaire II Recessed Fluorescent CFA2GPF217 or 317

Page 2 of 2

Direct/Indirect – 2' x 2' with Perforated Basket Air Supply and Return, 2 Lamp or 3 Lamp, T8

Model No. CFA2GPF217120SO

LER = FP - 50.2 IW - 30.08 BF - 0.93 Comparative yearly lighting energy cost per

1000 lumens = $4.78

Report Number: G2004248

Catalog Number: CFA2GPF217120SO

Lamps: F017/41K

Luminaire: Coffaire 2'x2' with perforated

basket I

Ballast: Triad C240S 120

Report is based on 1350 Lumens per lamp.

Efficiency: 61.7%

 

 

 

 

 

 

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.2

 

 

1.4

Shielding Angles:

 

 

55

 

 

65

Plane:

 

 

 

 

0-Deg

 

90-Deg

Luminous Length:

 

22.920

 

22.920

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.20

 

 

 

 

 

 

 

 

 

 

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

01

67

64

62

60

58

57

58

56

55

02

61

56

52

53

49

47

51

48

46

03

56

49

44

46

42

39

45

41

38

04

51

43

38

41

37

33

40

36

33

05

47

39

33

37

32

29

35

31

28

06

43

35

29

33

28

25

32

28

25

07

40

32

26

30

25

22

29

25

22

08

37

29

23

27

23

20

27

23

19

09

35

26

21

25

21

18

25

20

18

10

32

24

19

23

19

16

23

19

16

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG. 45-DEG. 90-DEG.

45

1443.

1668.

1856.

55

1301.

1656.

1928.

65

1089.

1605.

1815.

75

889.

1037.

1219.

85

508.

541.

575.

CANDELA DISTRIBUTION

 

0.0

45.0

90.0

FLUX

0

572

572

572

 

5

569

570

570

54

15

541

550

560

155

25

492

515

537

237

35

426

465

500

290

45

346

400

445

307

55

253

322

375

283

65

156

230

260

215

75

78

91

107

104

85

15

16

17

20

90

0

0

0

 

 

 

 

 

 

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

00-030

446

16.5

26.8

00-040

736

27.3

44.2

00-060

1327

49.1

79.7

00-090

1665

61.7

100.0

90-180

0000

0.0

000.0

00-180

1665

61.7

100.0

Model No. CFA2GPF317120O3

LER = FP - 48.7 IW - 46.5 BF - 1.00 Comparative yearly lighting energy cost per

1000 lumens = $0.00

Report Number: G2004249

Catalog Number: CFA2GPF317120O3

Lamps: F017/41K

Luminaire: Coffaire with perforated

basket I

Ballast: Triad B332 120

Report is based on 1350 Lumens per lamp. Efficiency: 55.9%

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.2

 

 

1.3

Shielding Angles:

 

 

55

 

 

65

Plane:

 

 

 

 

0-Deg

 

90-Deg

Luminous Length:

 

22.920

 

22.920

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.20

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

01

61

58

56

55

53

51

53

51

50

02

56

51

47

48

45

42

46

44

42

03

51

45

40

42

39

36

41

38

35

04

46

40

35

37

33

30

36

33

30

05

43

35

30

34

29

26

32

29

23

06

39

32

27

30

26

23

29

26

23

07

36

29

24

27

23

20

27

23

20

08

34

26

22

25

21

18

24

21

18

09

32

24

20

23

19

16

23

19

16

10

30

22

18

21

17

15

21

17

15

 

 

 

 

 

 

 

 

 

 

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE IN DEG. 0-DEG. 45-DEG. 90-DEG.

45 1985. 2269. 2503.

55 1779. 2216. 2535.

65 1452. 2094. 2359.

75 1174. 1516. 1675.

85 643. 745. 778.

CANDELA DISTRIBUTION

 

0.0

45.0

90.0

FLUX

0

800

800

800

 

5

794

796

798

76

15

754

766

780

217

25

684

712

741

329

35

591

638

682

399

45

476

544

600

417

55

346

431

493

380

65

208

300

338

283

75

103

133

147

137

85

19

22

23

27

90

0

0

0

 

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

00-030

621

15.3

27.4

00-040

1020

25.2

45.1

00-060

1817

44.9

80.3

00-090

2264

55.9

100.0

90-180

0000

00.0

000.0

00-180

2264

55.9

100.0

Ordering Information

Explanation of Catalog Number. Example: CFA2GPF217120SO

A

2

G

P

F

17

 

Coffaire II:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Body Style:

Fixture

Ceiling

Type:

Perforated

 

Direct/

A = Air Supply

Width

Standard Grid

Lamp

 

Indirect:

 

and Return

 

 

 

 

 

 

 

Shield

 

Recessed

 

 

 

 

 

 

 

 

 

 

 

 

 

with Perforated

 

 

 

 

 

 

 

 

 

 

 

 

 

Mesh Shield

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard Coffaire II

 

 

 

 

 

 

 

 

 

 

CF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CN

 

For NYC Code –Local 3 Manufactured

 

 

 

 

 

 

Flat

Lamp

 

 

 

Lamp:

White

Quantity

(By Others)

Reflector

2=2 Lamp

17=T8

 

3=3 Lamp

(Nominal 24")

Voltage:

 

 

 

 

 

 

 

Options:

120, 277 or

 

 

Add appropriate

UNV=120-277

 

 

suffix to catalog

 

 

 

 

no., ie: (GLR)

Ballast

Type:

 

 

 

 

<20THD <10THD

1 or 2 Lamp Elec. T8

SO *

HI *

1-3 Lamp Elec. T8

O3 *

H3 *

LOL Dimming T8

PS

*Instant Start Standard

Other dimming options. Consult factory.

NOTE: For T8 UNV, you must use HI,H3, Ballast Code.

Options/Accessories

Specifications (continued)

Optional supply air slot cover: Order Catalog Number: CACS-2

Fusing: Internal fast blow fusing: SUFFIX: GLR.

Internal slow blow fusing: SUFFIX: GMF.

Drywall Kit: Order Catalog Number: FK92X2.

Electrical Wiring Options: Consult factory.Chicago Plenum: SUFFIX: C.Dust Shield: See Folio Number: OA50-20

Specifications

Performance: In an installation of 2 lamp 40W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .64. To reduce glare the average brightness at 65° shall not exceed 1815 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 73.2%.

Materials: Chassis parts are die-formed code gauge steel.

Lamp Shield: 22 gauge steel perforated mesh lamp shield with white acrylic overlay.

Finish: Chassis exterior – soft white post painted polyester powder. Cavity – soft white post painted polyester powder. Reflector – soft white post painted polyester powder, minimum 88% reflectance. Rust preventive undercoating. Lamp Shield –white.

Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations.

Labels: I.B.E.W./UL and ULc Listed.

 

Job Information

Type:

 

 

 

 

 

 

 

Lightolier a Genlyte company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2007 a Genlyte company

Section 5/Folio M15-36

Page 2
Image 2
Lightolier CFA2GPF217 or 317 Page 2 of, Ordering Information, Options/Accessories, Specifications continued, Type