Coffaire II Recessed Fluorescent CFA2GPF217 or 317
Page 2 of 2
Direct/Indirect – 2' x 2' with Perforated Basket Air Supply and Return, 2 Lamp or 3 Lamp, T8
LER = FP - 50.2 IW - 30.08 BF - 0.93 Comparative yearly lighting energy cost per
1000 lumens = $4.78
Report Number: G2004248
Catalog Number: CFA2GPF217120SO
Lamps: F017/41K
Luminaire: Coffaire 2'x2' with perforated
basket I
Ballast: Triad C240S 120
Report is based on 1350 Lumens per lamp.
Efficiency: 61.7% |
|
|
|
|
|
| |||
CIE |
|
|
|
| |||||
Plane: |
|
|
|
|
| ||||
Spacing Criteria: |
|
| 1.2 |
|
| 1.4 | |||
Shielding Angles: |
|
| 55 |
|
| 65 | |||
Plane: |
|
|
|
|
| ||||
Luminous Length: |
| 22.920 |
| 22.920 | |||||
COEFFICIENTS OF UTILIZATION – |
|
| |||||||
ZONAL CAVITY METHOD. EFFECTIVE |
| ||||||||
FLOOR CAVITY REFLECTANCE 0.20 |
| ||||||||
|
|
|
|
|
|
|
|
|
|
RC |
| 80 |
|
| 50 |
|
| 30 |
|
RW | 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 |
01 | 67 | 64 | 62 | 60 | 58 | 57 | 58 | 56 | 55 |
02 | 61 | 56 | 52 | 53 | 49 | 47 | 51 | 48 | 46 |
03 | 56 | 49 | 44 | 46 | 42 | 39 | 45 | 41 | 38 |
04 | 51 | 43 | 38 | 41 | 37 | 33 | 40 | 36 | 33 |
05 | 47 | 39 | 33 | 37 | 32 | 29 | 35 | 31 | 28 |
06 | 43 | 35 | 29 | 33 | 28 | 25 | 32 | 28 | 25 |
07 | 40 | 32 | 26 | 30 | 25 | 22 | 29 | 25 | 22 |
08 | 37 | 29 | 23 | 27 | 23 | 20 | 27 | 23 | 19 |
09 | 35 | 26 | 21 | 25 | 21 | 18 | 25 | 20 | 18 |
10 | 32 | 24 | 19 | 23 | 19 | 16 | 23 | 19 | 16 |
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. | |||
45 | 1443. | 1668. | 1856. |
55 | 1301. | 1656. | 1928. |
65 | 1089. | 1605. | 1815. |
75 | 889. | 1037. | 1219. |
85 | 508. | 541. | 575. |
CANDELA DISTRIBUTION
| 0.0 | 45.0 | 90.0 | FLUX |
0 | 572 | 572 | 572 |
|
5 | 569 | 570 | 570 | 54 |
15 | 541 | 550 | 560 | 155 |
25 | 492 | 515 | 537 | 237 |
35 | 426 | 465 | 500 | 290 |
45 | 346 | 400 | 445 | 307 |
55 | 253 | 322 | 375 | 283 |
65 | 156 | 230 | 260 | 215 |
75 | 78 | 91 | 107 | 104 |
85 | 15 | 16 | 17 | 20 |
90 | 0 | 0 | 0 |
|
|
|
|
|
|
ZONAL LUMEN SUMMARY
ZONE | LUMENS | % LAMP | % FIXT |
446 | 16.5 | 26.8 | |
736 | 27.3 | 44.2 | |
1327 | 49.1 | 79.7 | |
1665 | 61.7 | 100.0 | |
0000 | 0.0 | 000.0 | |
1665 | 61.7 | 100.0 |
LER = FP - 48.7 IW - 46.5 BF - 1.00 Comparative yearly lighting energy cost per
1000 lumens = $0.00
Report Number: G2004249
Catalog Number: CFA2GPF317120O3
Lamps: F017/41K
Luminaire: Coffaire with perforated
basket I
Ballast: Triad B332 120
Report is based on 1350 Lumens per lamp. Efficiency: 55.9%
CIE |
|
|
|
| |||||
Plane: |
|
|
|
|
| ||||
Spacing Criteria: |
|
| 1.2 |
|
| 1.3 | |||
Shielding Angles: |
|
| 55 |
|
| 65 | |||
Plane: |
|
|
|
|
| ||||
Luminous Length: |
| 22.920 |
| 22.920 | |||||
COEFFICIENTS OF UTILIZATION – |
|
| |||||||
ZONAL CAVITY METHOD. EFFECTIVE |
| ||||||||
FLOOR CAVITY REFLECTANCE 0.20 |
| ||||||||
RC |
| 80 |
|
| 50 |
|
| 30 |
|
RW | 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 |
01 | 61 | 58 | 56 | 55 | 53 | 51 | 53 | 51 | 50 |
02 | 56 | 51 | 47 | 48 | 45 | 42 | 46 | 44 | 42 |
03 | 51 | 45 | 40 | 42 | 39 | 36 | 41 | 38 | 35 |
04 | 46 | 40 | 35 | 37 | 33 | 30 | 36 | 33 | 30 |
05 | 43 | 35 | 30 | 34 | 29 | 26 | 32 | 29 | 23 |
06 | 39 | 32 | 27 | 30 | 26 | 23 | 29 | 26 | 23 |
07 | 36 | 29 | 24 | 27 | 23 | 20 | 27 | 23 | 20 |
08 | 34 | 26 | 22 | 25 | 21 | 18 | 24 | 21 | 18 |
09 | 32 | 24 | 20 | 23 | 19 | 16 | 23 | 19 | 16 |
10 | 30 | 22 | 18 | 21 | 17 | 15 | 21 | 17 | 15 |
|
|
|
|
|
|
|
|
|
|
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE IN DEG.
45 1985. 2269. 2503.
55 1779. 2216. 2535.
65 1452. 2094. 2359.
75 1174. 1516. 1675.
85 643. 745. 778.
CANDELA DISTRIBUTION
| 0.0 | 45.0 | 90.0 | FLUX |
0 | 800 | 800 | 800 |
|
5 | 794 | 796 | 798 | 76 |
15 | 754 | 766 | 780 | 217 |
25 | 684 | 712 | 741 | 329 |
35 | 591 | 638 | 682 | 399 |
45 | 476 | 544 | 600 | 417 |
55 | 346 | 431 | 493 | 380 |
65 | 208 | 300 | 338 | 283 |
75 | 103 | 133 | 147 | 137 |
85 | 19 | 22 | 23 | 27 |
90 | 0 | 0 | 0 |
|
ZONAL LUMEN SUMMARY
ZONE | LUMENS | % LAMP | % FIXT |
621 | 15.3 | 27.4 | |
1020 | 25.2 | 45.1 | |
1817 | 44.9 | 80.3 | |
2264 | 55.9 | 100.0 | |
0000 | 00.0 | 000.0 | |
2264 | 55.9 | 100.0 |
Ordering Information
Explanation of Catalog Number. Example: CFA2GPF217120SO
A
2
G
P
F
17
| Coffaire II: |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Body Style: | Fixture | Ceiling | Type: | Perforated | |||||||||||
| Direct/ | A = Air Supply | Width | Standard Grid | Lamp | |||||||||||
| Indirect: |
| and Return |
|
|
|
|
|
|
| Shield | |||||
| Recessed |
|
|
|
|
|
|
|
|
|
|
|
|
| ||
with Perforated |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Mesh Shield |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
| Standard Coffaire II |
|
|
|
|
|
|
|
|
| |||
| CF |
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
| |||||
| CN |
| For NYC Code |
|
|
|
|
|
|
Flat | Lamp |
|
|
|
Lamp: | ||||
White | Quantity | (By Others) | ||
Reflector | 2=2 Lamp | 17=T8 | ||
| 3=3 Lamp | (Nominal 24") |
Voltage: |
|
|
|
|
|
|
| Options: | |||
120, 277 or |
|
| Add appropriate | ||
|
| suffix to catalog | |||
|
|
|
| no., ie: (GLR) | |
Ballast | Type: |
|
| ||
|
| <20THD <10THD | |||
1 or 2 Lamp Elec. T8 | SO * | HI * | |||
O3 * | H3 * | ||||
LOL Dimming T8 | PS | – |
*Instant Start Standard
Other dimming options. Consult factory.
NOTE: For T8 UNV, you must use HI,H3, Ballast Code.
Options/Accessories
Specifications (continued)
Optional supply air slot cover: Order Catalog Number:
Fusing: Internal fast blow fusing: SUFFIX: GLR.
Internal slow blow fusing: SUFFIX: GMF.
Drywall Kit: Order Catalog Number: FK92X2.
Electrical Wiring Options: Consult factory.Chicago Plenum: SUFFIX: C.Dust Shield: See Folio Number:Specifications
Performance: In an installation of 2 lamp 40W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .64. To reduce glare the average brightness at 65° shall not exceed 1815 candelas per square meter. To control veiling reflections, luminaire output in the
Materials: Chassis parts are
Lamp Shield: 22 gauge steel perforated mesh lamp shield with white acrylic overlay.
Finish: Chassis exterior – soft white post painted polyester powder. Cavity – soft white post painted polyester powder. Reflector – soft white post painted polyester powder, minimum 88% reflectance. Rust preventive undercoating. Lamp Shield
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations.
Labels: I.B.E.W./UL and ULc Listed.
| Job Information | Type: |
|
|
| ||
|
|
|
|
Lightolier a Genlyte company | www.lightolier.com |
Technical Information: (978)
631 Airport Road, Fall River, MA 02720 • (508)
© 2007 a Genlyte company | Section 5/Folio |