Lightolier CFH2GPF332 Page 2 of, Ordering Information, Options/Accessories, Specifications, Type

Models: CFH2GPF232 CFH2GPF332

1 2
Download 2 pages 11.45 Kb
Page 2
Image 2
Page 2 of 2

Model No. CFH2GPF232120SOCoffaire II Recessed Fluorescent CFH2GPF232 or 332

Page 2 of 2

Direct/Indirect – with Perforated Basket Air Return/Static, 2 Lamp or 3 Lamp T8

Model No. CFH2GPF232120SO

LER = FP - 54.7 IW - 58.0 BF - 0.87 Comparative yearly lighting energy cost per

1000 lumens = $4.39

Report Number: G2004255

Catalog Number: CFH2GPF232120SO

Lamps: F32/T8 TL841

Luminaire: Coffaire II with perforated basket

Ballast: Triad B232IUNV-HP, 58 watts Report is based on 2850 Lumens per lamp.

Efficiency: 63.8%

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.2

 

 

1.4

Shielding Angles:

 

 

90

 

 

90

Plane:

 

 

 

 

0-Deg

 

90-Deg

Luminous Length:

 

46.920

 

22.920

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.200

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

01

69

66

63

62

60

58

59

58

56

02

63

57

53

54

50

47

52

49

46

03

57

50

45

47

43

39

45

42

39

04

52

44

38

42

37

33

40

36

33

05

48

39

33

37

32

29

36

32

28

06

44

35

29

33

29

25

32

28

25

07

41

32

26

30

25

22

29

25

22

08

38

29

23

28

23

19

27

23

19

09

35

27

21

25

21

18

25

20

17

10

33

25

19

24

19

16

23

19

16

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG. 45-DEG. 90-DEG.

45

1512.

1734.

1897.

55

1394.

1771.

1994.

65

1217.

1800.

2093.

75

0974.

1715.

1353.

85

0612.

0711.

0777.

CANDELA DISTRIBUTION0

 

 

 

0.0

45.0

90.0

FLUX

0

1179

1179

1179

 

5

1172

1174

1176

112

15

1120

1135

1151

321

25

1028

1067

1105

492

35

899

972

1031

606

45

742

851

931

651

55

555

705

794

618

65

357

528

614

504

75

175

308

243

281

85

37

43

47

52

90

0

0

0

 

 

 

 

 

 

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

00-030

925

16.2

25.4

00-040

1531

26.9

42.1

00-060

2800

49.1

77.0

00-090

3636

63.8

100.0

90-180

0000

0.0

000.0

00-180

3636

63.8

100.0

Model No. CFH2GPF332120O3

LER = FP - 50.7 IW - 85 BF - 0.88 Comparative yearly lighting energy cost per

1000 lumens = $4.73

Report Number: G2004256

Catalog Number: CFH2GPF332120O3

Lamps: F32T8 TL841

Luminaire: Coffaire II with perforated basket

Ballast: SYL QT3X32T8 120, 89.0 watts Report is based on 2850 Lumens per lamp.

Efficiency: 60.2%

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.2

 

 

1.3

Shielding Angles:

 

 

90

 

 

90

Plane:

 

 

 

 

0-Deg

 

90-Deg

Luminous Length:

 

46.920

 

22.920

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.200

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

01

66

63

60

59

57

55

56

55

53

02

59

54

50

51

48

45

49

46

44

03

54

48

43

45

41

38

43

40

37

04

49

42

37

40

35

32

38

35

31

05

45

37

32

36

31

27

34

30

27

06

42

34

28

32

27

24

31

27

24

07

39

30

25

29

24

21

28

24

21

08

36

28

23

27

22

19

26

22

19

09

34

25

20

24

20

17

24

20

17

10

32

23

19

23

18

15

22

18

15

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG. 45-DEG. 90-DEG.

45

2192.

2472.

2669.

55

2012.

2469.

2720.

65

1718.

2427.

2758.

75

1358.

2193.

1865.

85

843.

959.

1041.

CANDELA DISTRIBUTION0

 

0.0

45.0

90.0

FLUX

0

1733

1733

1733

 

5

1722

1725

1729

164

15

1645

1668

1693

472

25

1507

1563

1613

720

35

1316

1412

1483

879

45

1076

1213

1310

930

55

801

983

1083

863

65

504

712

809

682

75

244

394

335

369

85

51

58

63

72

90

0

0

0

 

 

 

 

 

 

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

00-030

1356

15.9

26.3

00-040

2235

26.1

43.4

00-060

4027

47.1

78.2

00-090

5150

60.2

100.0

90-180

0000

00.0

000.0

00-180

5150

60.2

100.0

Ordering Information

Explanation of Catalog Number. Example: CFH2GPF232120SO

 

 

 

 

 

 

 

 

 

 

2

 

 

G

 

P

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Coffaire II:

 

Body Style:

Fixture

Ceiling

Type:

Perforated

 

Direct/

S = Static

Width

 

Fits both

Lamp

 

Indirect:

H = Air Return

 

 

 

Standard Grid

Shield

 

Recessed

 

 

 

 

 

 

 

 

and

 

 

with Perforated

 

 

 

 

 

 

 

 

Slot Grid

 

 

 

Mesh Shield

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CF

 

Standard Coffaire II

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CY

 

 

For NYC Code – I.B.E.W. Manufactured

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CN

 

For NYC Code – Local 3 Manufactured

 

 

 

 

 

 

F

Flat

White

Reflector

 

 

 

32

 

 

 

 

 

Lamp

 

Lamp:

Quantity

 

(By Others)

2=2 Lamp

 

32=T8

3=3 Lamp

(Nominal 48")

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage:

 

 

Options:

120, 277 or

 

Add appropriate

UNV=120-277

 

suffix to catalog

 

 

 

 

 

 

no., ie: (GLR)

Ballast Type:

<20THD <10THD

1 or 2 Lamp Elec. T8 SO*

HI*

1-3 Lamp Elec. T8

O3*

H3*

LOL Dimming T8

PS*

*Instant Start Standard

Other dimming options. Consult factory.

NOTE:

For T8 UNV, you must use HI, H3

Ballast Code.

Options/Accessories

Fusing: Internal fast blow fusing: SUFFIX: GLR.Internal slow blow fusing: SUFFIX: GMF.

Drywall Kit: Order Catalog Number: FK92X4 and CF4FK SPACER.

Electrical Wiring Options: Consult factory.Chicago Plenum: SUFFIX: C.

Specifications

Performance: In an installation of 2 lamp 32W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .66. To reduce glare the average brightness at 65° shall not exceed 2093 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 74.6%.

Materials: Chassis parts are die-formed code gauge steel.

Lamp Shield: 22 gauge steel perforated mesh lamp shield with white acrylic overlay.

Finish: Chassis exterior – baked white post painted acrylic enamel. Cavity – baked white post painted acrylic enamel. Reflector – baked white post painted

Specifications (continued)

acrylic enamel, minimum 86% reflectance. Phosphate undercoating. Lamp Shield – baked flat white acrylic enamel.

Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed.

Job Information

Type:

 

 

Lightolier a Genlyte company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710

We reserve the right to change details of design, materials and finish.

© 2005 a Genlyte company

Section 5/Folio M15-55

Page 2
Image 2
Lightolier CFH2GPF332 Page 2 of, Ordering Information, Options/Accessories, Specifications continued, Folio M15-55