Lighting Systems CL-1

1BHFPG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Covelite™-BNQ5QFS'PPU4FDUJPO

Performance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CANDLEPOWER CURVE

 

 

 

CANDLEPOWER

 

 

 

 

 

 

COEFFICIENTS OF UTILIZATION

 

 

 

 

 

 

 

 

Zone

0

22

45

67

90

112

135

157

180

 

 

% EFFECTIVE CEILING CAVITY REFLECTANCE

 

1000

175

165

155

145

135

Deg.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

125

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CANDELAS

 

 

 

 

 

 

 

80

 

 

70

 

 

50

 

800

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

600

 

 

 

 

115

180

433

433

433

433

433

433

433

433

433

 

 

50

30

% WALL REFLECTANCE

30

10

 

 

 

 

 

175

540

524

514

464

444

393

382

352

344

 

 

10

50

30

10

50

400

 

 

 

 

105

 

1

62

59

57

53

51

49

36

35

34

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

165

772

739

678

535

438

303

238

171

160

RATIO

2

54

50

47

47

43

40

32

30

28

 

 

 

 

 

 

200

 

 

 

 

95

155

985

926

816

579

411

199

153

96

91

3

48

43

39

41

37

34

28

26

24

 

 

 

 

 

90

135

1142

1084

959

608

297

74

25

6

0

CAVITY

4

42

37

32

36

32

28

25

22

20

 

 

 

 

 

6

33

27

23

28

24

20

19

17

14

 

 

 

 

 

85

145

1142

1099

952

607

364

122

76

39

30

 

5

37

31

27

32

27

24

22

19

17

 

 

 

 

 

75

115

1034

988

816

487

145

0

0

0

0

ROOM

7

29

24

20

25

21

17

17

15

12

 

 

 

 

 

9

24

19

15

21

16

13

14

11

9

 

 

 

 

 

 

125

1154

1034

888

619

231

33

0

0

0

 

8

26

21

17

23

18

15

16

13

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

 

 

 

 

 

 

 

 

 

 

 

10

22

17

13

19

15

12

13

10

8

 

 

 

 

 

 

105

721

703

660

385

85

0

0

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

55

95

255

250

227

180

33

0

0

0

0

 

 

 

20% FLOOR CAVITY REFLECTANCE

 

 

5

 

25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

15

35

45

90

72

66

46

25

0

0

0

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REPORT NO: LRL896-1F

0

0

0

0

0

0

0

0

0

0

 

 

 

 

 

 

 

 

 

 

 

Distribution Summary

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LAMP: 1-F32T8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LUMENS: 2900

 

 

Zone

 

Lumens

% Barelamp

%Luminaire

 

 

 

 

 

 

 

 

 

 

 

EFFICIENCY: 75.3%

 

0-90

 

769

 

 

0.0

 

 

0.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90-180

2184

 

 

75.3

 

 

100.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0-180

 

2184

 

 

75.3

 

 

100.00

 

 

 

 

 

 

 

 

 

 

 

 

Quick Calculators and Ceiling Brightness

Readings are rounded off based on initial footcandles at center of 20-foot run of luminaires. Room reflectance is 80% ceiling, 50% wall and 20% floor.

 

 

 

 

 

1Lt, 2 Fixtures, 2 Walls, 11" (0.28m) from Ceiling

 

 

 

 

 

 

 

Distance from wall

 

 

 

 

 

0'

2'

 

4'

6'

8'

10'

12'

 

14'

 

 

 

0

0.61m

1.22m

1.83m

2.44m

3.05m

3.66m

4.27m

 

 

From Ceiling

11" (0.28m)

 

 

 

105

32

14

14

32

105

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8'6" (2.59m)

 

36

 

36

35

35

36

36

 

 

Distance

9'6" (2.90m)

 

34

 

34

34

34

34

34

 

 

10'6" (3.20m)

 

31

 

32

32

32

32

31

 

 

 

 

 

 

 

 

11'6" (3.51m)

 

30

 

30

30

30

30

30

 

 

 

12'6" (3.81m)

 

28

 

29

29

29

29

28

 

 

 

 

 

 

 

1Lt, 2 Fixtures, 2 Walls, 14" (0.36m) from Ceiling

 

 

 

 

 

 

 

Distance from wall

 

 

 

 

 

0'

2'

 

4'

6'

8'

10'

12'

 

14'

 

 

 

0

0.61m

1.22m

1.83m

2.44m

3.05m

3.66m

4.27m

 

 

From Ceiling

14" (0.36m)

 

 

 

116

44

17

17

44

116

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8'6" (2.59m)

 

35

 

36

35

35

36

35

 

 

Distance

9'6" (2.90m)

 

33

 

34

34

34

34

33

 

 

 

 

 

 

 

 

10'6" (3.20m)

 

31

 

32

32

32

32

31

 

 

 

11'6" (3.51m)

 

29

 

30

30

30

30

29

 

 

 

12'6" (3.81m)

 

27

 

28

29

29

28

27

 

 

 

 

 

 

 

1Lt, 1 Fixture, 1 Wall, 11" (0.28m) from Ceiling

 

 

 

 

 

 

 

 

Distance from wall

 

 

 

 

0'

2'

 

4'

6'

8'

10'

12'

14'

 

 

 

0

0.61m

1.22m

1.83m

2.44m

3.05m

3.66m

4.27m

 

 

From Ceiling

11" (0.28m)

 

 

 

100

27

8

6

5

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8'6" (2.59m)

 

26

 

24

20

15

12

10

 

Distance

9'6" (2.90m)

 

23

 

22

18

15

12

10

 

10'6" (3.20m)

 

21

 

20

17

15

12

10

 

 

 

 

 

 

11'6" (3.51m)

 

19

 

18

16

14

12

10

 

 

12'6" (3.81m)

 

18

 

17

15

14

12

10

 

Maximum Candle Power:1154 CD at 125° Brightness ratio on vertical wall above fixture is:

1:1.5 when mounted 11" (0.28m) from ceiling; 1:1.7 when mounted 14" (0.36m) from ceiling.

 

 

 

 

 

1Lt, 2 Fixtures, 1 Wall, 14" (0.36m) from Ceiling

 

 

 

 

 

 

 

 

Distance from wall

 

 

 

 

0'

2'

 

4'

6'

8'

10'

12'

14'

 

 

 

0

0.61m

1.22m

1.83m

2.44m

3.05m

3.66m

4.27m

 

 

From Ceiling

14" (0.36m)

 

 

 

111

39

10

7

5

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8'6" (2.59m)

 

25

 

23

20

16

12

10

 

Distance

9'6" (2.90m)

 

23

 

21

18

15

12

10

 

 

 

 

 

 

10'6" (3.20m)

 

20

 

19

17

15

12

10

 

 

11'6" (3.51m)

 

19

 

18

16

14

12

10

 

 

12'6" (3.81m)

 

17

 

17

15

13

12

10

 

Job Information

Type:

"JSQPSU3PBE'BMM3JWFS."t  t'BY  

We reserve the right to change details of design, materials and finish.

XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt #

Page 2
Image 2
Lightolier CL-1 manual Quick Calculators and Ceiling Brightness, Candlepower Curve, Report no LRL896-1F

CL-1 specifications

Lightolier has long been a trusted name in the lighting industry, and one of its standout products is the Lightolier CL-1. This innovative lighting fixture is designed to meet the diverse needs of both residential and commercial spaces while maximizing energy efficiency and performance.

The Lightolier CL-1 is known for its sleek and modern design, making it an aesthetically pleasing addition to any environment. Its compact form factor allows for seamless integration into various applications, whether used in a home office, retail store, or hospitality setting. The CL-1's versatility is further enhanced by its range of customizable options, catering to different user preferences and lighting requirements.

One of the main features of the CL-1 is its advanced LED technology. The fixture utilizes high-quality LED components that not only provide significant energy savings compared to traditional lighting solutions but also boast a long lifespan. This means that users can expect reduced maintenance costs and less frequent replacements, leading to more sustainable lighting choices.

The Lightolier CL-1 is also equipped with smart lighting capabilities. It can be easily integrated into existing smart home systems or commercial building management systems, allowing users to control their lighting from mobile devices or central control panels. This feature enables added convenience and flexibility in lighting management, whether adjusting brightness levels throughout the day or setting schedules for optimal energy use.

With a focus on user experience, the CL-1 offers a range of color temperature options, from warm white to cool daylight. This flexibility ensures that users can create the perfect ambiance for any occasion. The fixture also features dimming capabilities, allowing for fine-tuned control over lighting intensity, which can enhance comfort and functionality in any space.

The durability of the Lightolier CL-1 is another significant characteristic. Constructed from high-quality materials, it is built to withstand the demands of everyday use while maintaining its aesthetic appeal. This reliability makes the CL-1 an ideal choice for a variety of environments, ensuring that it meets both performance and aesthetic expectations.

In summary, the Lightolier CL-1 represents a harmonious blend of style, efficiency, and advanced technology. Its LED capabilities, smart integration, customizable features, and robust construction make it a leading choice for anyone seeking a high-quality lighting solution that meets the needs of modern living and working spaces. With the CL-1, Lightolier continues to set the standard for innovative lighting solutions in the industry.