Lightolier CL-4 1BHFPG, Performance, Quick Calculators & Ceiling Brightness, Candlepower

Models: CL-4

1 2
Download 2 pages 30.2 Kb
Page 2
Image 2
1BHFPG

Lighting Systems CL-4

1BHFPG

Covelite™-BNQ5QFS$SPTT4FDUJPO

Performance

CANDLEPOWER CURVE

REPORT NO: LRL 400-5B

LAMPS: 1 F54T5

LUMENS: 5000

EFFICIENCY = 80.0%

 

 

 

CANDLEPOWER

 

 

 

 

 

 

 

COEFFICIENTS OF UTILIZATION

 

 

Zone

0

22

45

67

90

112

135

157

180

 

 

% EFFECTIVE CEILING CAVITY REFLECTANCE

 

 

Deg.

 

 

 

CANDELAS

 

 

 

 

 

 

 

80

 

 

 

70

 

 

 

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

% WALL REFLECTANCE

 

 

 

180

789

789

789

789

789

789

789

789

789

 

 

70

50

30

 

70

50

30

 

50

30

10

 

175

950

952

864

971

768

743

658

646

630

0

 

76

76

76

 

65

65

65

 

44

44

44

 

1

 

69

66

63

 

59

57

54

 

39

37

36

165

1169

1167

1083

983

734

589

416

380

361

 

 

 

2

 

63

58

53

 

54

49

46

 

34

32

30

155

1467

1407

1164

1013

670

435

284

275

220

3

 

57

51

45

 

49

43

39

 

30

27

25

4

 

52

45

39

 

45

38

34

 

26

23

21

145

1751

1693

1340

983

576

301

160

104

79

 

 

 

5

 

48

39

33

 

41

34

29

 

23

20

18

135

1955

1784

1412

937

460

187

53

16

15

6

 

44

35

29

 

37

30

25

 

21

18

15

125

2453

2390

1551

987

357

98

13

14

14

7

 

40

31

25

 

34

27

22

 

19

15

13

8

 

37

28

22

 

32

24

19

 

17

14

11

115

2124

2075

1871

815

241

17

7

7

8

 

 

 

9

 

34

25

20

 

29

22

17

 

15

12

10

105

1364

1322

1295

922

106

8

7

10

10

10

32

23

18

 

27

20

16

 

14

11

9

 

 

 

20% FLOOR CAVITY REFLECTANCE

 

 

 

95

561

533

514

362

22

6

8

10

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90

64

37

64

13

13

5

11

8

10

 

 

 

 

Distribution Summary

 

 

 

 

85

8

8

11

4

10

6

10

10

11

 

Zone

 

 

 

 

 

 

 

Lumens

 

% Barelamp

 

Luminaire

 

 

 

 

 

 

 

 

 

 

 

0-90

 

0

 

 

 

0

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

90-180

 

4002

 

 

 

80.0

 

 

100.00

 

 

 

 

 

 

 

 

 

 

 

0-180

 

4002

 

 

 

80.0

 

 

100.00

Quick Calculators & Ceiling Brightness

Readings are rounded off based on initial footcandles at center of 20-foot run of luminaries. Room reflectance are 80% ceiling, 50% wall and 20% floor.

 

 

 

 

 

T5

54W, 2 Fixtures, 2 Walls, 14" (0.36) from Ceiling

 

 

 

 

 

 

 

 

 

Distance from wall

 

 

 

 

 

 

 

 

1'

 

3'

5'

7'

9'

11'

13'

 

 

 

 

 

 

0.30m

0.91m

1.52m

2.13m

2.74m

3.35m

3.96m

 

 

 

 

 

 

Ceiling

 

14" (0.36m)

 

268

119

47

36

47

119

268

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

From

 

 

 

 

 

 

 

 

 

 

 

 

 

8'6" (2.59m)

 

76

 

81

82

82

82

81

76

 

 

 

 

 

 

 

 

Distance

9'6" (2.90m)

 

73

 

77

79

79

79

77

73

 

 

10'6" (3.20m)

 

70

 

74

76

76

76

74

70

 

 

 

 

 

 

 

 

 

 

11'6" (3.51m)

 

67

 

71

73

73

73

71

67

 

 

 

 

12'6" (3.81m)

 

62

 

66

68

68

68

66

62

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T5 54W, 1 Fixture, 1 Wall, 14" (0.36) from Ceiling

 

 

 

 

 

 

 

 

Distance from wall

 

 

 

 

 

 

 

1'

3'

5'

7'

9'

11'

13'

 

 

 

 

 

0.30m

0.91m

1.52m

2.13m

2.74m

3.35m

3.96m

 

 

 

 

From Ceiling

14" (0.36m)

 

 

316

86

27

15

11

9

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8'6" (2.59m)

 

56

56

50

41

33

27

22

 

Distance

9'6" (2.90m)

 

52

51

47

40

33

28

23

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10'6" (3.20m)

 

 

48

48

44

39

33

28

24

 

 

 

 

 

11'6" (3.51m)

 

44

44

42

37

33

28

24

 

 

12'6" (3.81m)

 

38

38

37

33

29

26

23

 

Maximum Candle Power: 2453 CD at 125°

 

 

 

 

T5 54W, 2 Fixtures, 2 Walls, 18" (0.46) from Ceiling

 

 

 

 

 

 

Distance from wall

 

 

 

 

 

1'

3'

5'

7'

9'

11'

13'

 

 

 

0.30m

0.91m

1.52m

2.13m

2.74m

3.35m

3.96m

 

 

Ceiling

18" (0.46m)

 

271

120

48

36

48

120

271

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

From

 

 

 

 

 

 

 

 

 

 

 

8'6" (2.59m)

 

 

78

83

84

84

84

83

78

 

 

 

 

Distance

9'6" (2.90m)

 

74

79

80

81

80

79

74

 

10'6" (3.20m)

 

 

71

75

77

78

77

75

71

 

 

 

 

 

11'6" (3.51m)

 

68

72

74

75

74

72

68

 

 

12'6" (3.81m)

 

62

65

67

68

67

65

62

 

 

 

 

 

 

 

T5 54W, 1 Fixtures, 1 Wall, 18" (0.46) from Ceiling

 

 

 

 

 

 

 

 

Distance from wall

 

 

 

 

 

 

1'

3'

5'

7'

9'

11'

13'

 

 

 

 

0.30m

0.91m

1.52m

2.13m

2.74m

3.35m

3.96m

 

 

 

 

From Ceiling

18" (0.46m)

 

 

261

109

35

18

12

10

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8'6" (2.59m)

 

54

54

49

41

34

27

23

Distance

9'6" (2.90m)

 

49

50

46

40

34

28

24

 

 

 

 

 

 

 

 

 

 

 

 

10'6" (3.20m)

 

 

46

46

44

39

33

28

24

 

 

 

11'6" (3.51m)

 

43

43

41

37

33

28

25

 

12'6" (3.81m)

 

38

39

37

34

30

27

24

Data is based on bare lamp photometrics. Dashed lines in beam spreads indicate narrow axes of oval shaped beams.

FC is initial footcandles at center of beam.

L and W are to the point that the candlepower drops 50% of maximum.

Job Information

Type:

"JSQPSU3PBE'BMM3JWFS."t  t'BY  

We reserve the right to change details of design, materials and finish.

XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt #

Page 2
Image 2
Lightolier 1BHFPG, Performance, Quick Calculators & Ceiling Brightness, Candlepower Curve, Lighting Systems CL-4