Section 6/Folio N40-14

Cleanguard Class 1,000/10,000 Clean Room CXSW SERIES

Page 2 of 2

Recessed Fluorescent, 2x2, for 15/16" to 1-1/2" wide face T-bar

 

2 or 3 Lamp

Photometry

Model No. CXS2WFAVI26U120SO

G02023DATE: 02-04-02 CXS2WFAVI26U120SO

2 TS U6, EACH RATED 2750 LUMENS FIXTURE WITH FS FRAME AND INVERTED LENS

LER = FP - 56.0

 

IW - 53.7

BF - 0.87

 

 

 

 

 

 

Comparative yearly lighting energy cost per 1000 lumens = $4.24

 

 

 

coefficients of utilization — zonal cavity method

 

 

 

 

 

 

 

RF

 

 

20

 

 

20

 

 

20

 

 

RC

 

 

80

 

 

50

 

 

30

 

 

RW

 

70

50

30

50

30

10

50

30

10

 

1

 

69

66

63

62

60

58

59

58

56

ratio

2

 

63

58

54

54

51

48

52

50

47

3

 

57

51

46

48

44

41

46

43

40

 

 

cavity

4

 

53

45

40

43

38

35

41

38

34

5

 

48

41

35

38

34

30

37

33

30

room

6

 

45

37

31

35

30

27

34

30

26

7

 

42

33

28

32

27

24

31

27

23

 

8

 

39

30

25

29

24

21

28

24

21

 

9

 

36

28

23

27

22

19

26

22

19

 

10

 

34

26

21

25

20

17

24

20

17

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD PERFORMANCE MAY VARY FROM LABORATORY PERFORMANCE.

Ordering Information

Explanation of Catalog Number. Example: CXS2WFAVI26U120SOGLR

CX

S

2

W

FA

VI

Cleanguard

Static

Fixture

Ceiling Type:

Lens Frame:

 

 

 

Lamp Quantity:

 

 

 

Clean Room:

 

Width

W = Grid 15/16"

FA = Flat

 

 

 

 

2= 2 Lamp

 

Class 1,000,

 

 

to 1-1/2" face

aluminum

 

 

 

 

3= 3 Lamp

 

10,000 or

 

 

(lay in T-bar)

frame

 

 

 

 

 

 

 

 

100,000

 

 

 

 

 

 

 

 

 

 

 

 

Clean Room

 

 

 

 

 

 

 

 

 

Lamp

 

 

 

 

 

Lens Shielding

Fixture Length:

 

 

 

 

 

 

Type:

2U = T8, 1-5/8" U Lamp

 

 

 

 

 

VI (virgin acrylic) .125

17 = T8, 2' Lamp

 

 

 

 

 

standard. For options

6U = 6" U Lamp (T8)

 

 

 

 

 

consult factory.

(2 Lamp Only)

 

 

 

 

 

Smooth side of

FT = Twin Tube (T5)

 

 

 

 

 

lens towards room.

(Nominal 24")

Options & Accessories

Fusing: Internal fast-blow fusing. Suffix: GLR.

Internal slow-blow fusing. Suffix: GMF.

Electrical/Wiring Options: Consult factory.

Voltage:

 

 

 

 

 

Options:

120 or 277

 

Add appropriate

 

 

 

suffix to catalog

 

 

 

no, ie: (GLR)

 

 

 

 

 

Ballast Type:

<20THD <10THD

1-1

&

1-2 Lamp Elec. T8

SO*

HI*

1-3

Lamp Elec. T8

O3*

H3*

1-1

&

1-2 Lamp Elec. TT5 SB*

IB*

(40

Watt)

 

I3*

1-3

Lamp Elec. TT5

X3*

LOL T8 Dimming

PS*

LOL TT5 Dimming

PB*

*Instant Start Standard

Other dimming options, consult factory.

Specifications

Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing with side rails hemmed over and housing ends turned-in for safe handling. Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Phosphate undercoating.

Lenses: VI (standard extruded virgin acrylic, 3/16" square based female cones, running 45° to the panel edge, .125" nominal thickness (pattern 12) installed smooth side down.

Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

Labels: I.B.E.W./UL and ULc listed.

Job Information

 

Type:

 

 

 

Lightolier a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. Copyright 2004 Lightolier

Page 2
Image 2
Lightolier CXSW-SERIES2X2 dimensions Photometry, Ordering Information, Options & Accessories, Specifications