Cleanguard Class 1,000/10,000 Clean Room CXSW SERIES
Page 2 of 2 | Recessed Fluorescent, 2x4, for 15/16" to |
| 2, 3 or 4 Lamp, T8 |
Photometry | Model No. CXS2WFAVI332120O3 |
G02021DATE:
3 F32/T8 TL841, EACH RATED 2850 LUMENS. FIXTURE WITH INVERTED VI LENS IN FS F
LER = FP - 73.2 |
| IW - 108.7 | BF - 0.88 |
|
|
|
|
|
| ||
Comparative yearly lighting energy cost per 1000 lumens = $3.28 |
|
|
| ||||||||
coefficients of utilization — zonal cavity method |
|
|
|
|
|
| |||||
| RF |
|
| 20 |
|
| 20 |
|
| 20 |
|
| RC |
|
| 80 |
|
| 50 |
|
| 30 |
|
| RW |
| 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 |
| 1 |
| 74 | 71 | 68 | 67 | 64 | 62 | 64 | 62 | 61 |
ratio | 2 |
| 68 | 62 | 57 | 58 | 55 | 52 | 56 | 53 | 51 |
3 |
| 62 | 55 | 49 | 51 | 47 | 44 | 50 | 46 | 43 | |
|
| ||||||||||
cavity | 4 |
| 56 | 48 | 43 | 46 | 41 | 37 | 44 | 40 | 37 |
5 |
| 52 | 43 | 37 | 41 | 36 | 32 | 40 | 35 | 32 | |
room | 6 |
| 48 | 39 | 33 | 37 | 32 | 28 | 36 | 31 | 28 |
7 |
| 45 | 35 | 30 | 34 | 29 | 25 | 33 | 28 | 25 | |
| 8 |
| 41 | 32 | 27 | 31 | 26 | 22 | 30 | 26 | 22 |
| 9 |
| 39 | 30 | 24 | 29 | 24 | 20 | 28 | 23 | 20 |
| 10 |
| 36 | 27 | 22 | 26 | 22 | 18 | 26 | 21 | 18 |
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD PERFORMANCE MAY VARY FROM LABORATORY PERFORMANCE.
Ordering Information
Explanation of Catalog Number. Example: CXS2WFAVI332120O3GLR
CX
Cleanguard
Clean Room:
Class 1,000,
10,000 or
100,000
Clean Room
S
Static
2 |
| W |
|
| FA |
| VI |
|
|
|
|
| 32 |
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Fixture | Ceiling Type: |
| Lens Frame: |
|
| Lamp Quantity: |
| Lamp | |||||||||||
Width | W = Grid 15/16" | FA = Flat |
|
|
| 2=2 Lamp | Fixture Length: | ||||||||||||
|
|
| to |
| aluminum |
|
|
| 3=3 Lamp |
| 32=T8 | ||||||||
|
|
| (lay in |
| frame |
|
|
| 4=4 Lamp | (Nominal 48") | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Lens Shielding
Type:
VI (virgin acrylic) .125 standard. For options consult factory. Smooth side of
lens towards room.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Voltage: |
|
| Options: | |||||
120 or 277 |
| Add appropriate | ||||||
|
|
|
|
| suffix to catalog | |||
|
|
|
|
|
| no, ie: (GLR) | ||
|
|
|
|
|
|
|
|
|
Ballast Type:
<20THD <10THD
1 & 2 Lamp Elec. T8 | SO* | HI* |
SO* | HI* | |
O3* | H3* | |
O4* | H4* | |
LOL Dimming T8 | PS* | – |
*Instant Start Standard
Other dimming options, consult factory.
Options & Accessories
Fusing: Internal fast-blow fusing. Suffix: GLR.
Internal slow-blow fusing. Suffix: GMF.
Electrical/Wiring Options: Consult factory.Specifications
Materials: Chassis parts are
Lenses: VI (standard extruded virgin acrylic, 3/16" square based female cones, running 45° to the panel edge, .125" nominal thickness (pattern 12) installed smooth side down.
Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W./UL and ULc listed.
Job Information |
| Type: |
|
|
|
Lightolier a Genlyte Thomas Company | www.lightolier.com |
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508)