Architectural Decorative Vetro Downlight  D01

Page 3 of 3

Compact Fluorescent

 

8011CL-D4AO1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90°

Calculite 4” Vetro Downlight, Cat.# 8011Cl D4A01

 

 

 

 

 

 

Coefficients of Utilization

 

 

 

 

 

 

 

 

18W G.E. Biax T/E triple Tube. Lumen Rating = 1200 LMS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ceiling

 

80%

 

 

70%

 

50%

 

 

30%

 

 

10%

 

 

 

Universal Ballast #C218UNVBES

 

 

 

 

 

 

 

 

 

 

 

Candlepower summary

Wall

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

 

 

RCR

 

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

 

 

 

 

 

 

 

 

 

 

Angle

Mean CP

Lumens

 

0

.41 .41 .41 .41

.40

.40

.40

.40

.38

.38

.38

.36 .36 .36

.35

.35 .35 .34

75

60°

0

244

 

 

1

.39

.37

.36

.35

.38

.37

.36

.35

.35

.34

.34

.34

.33

.33

.33

.32

.32

.31

 

5

239

23

 

2

.36

.34

.33

.32

.36

.34

.32

.31

.33

.32

.30

.32

.31

.30

.31

.30

.29

.29

 

 

Ratio

 

 

10

254

 

3

.34 .32 .30 .28

.34

.31

.30

.28

.30

.29

.28

.30 .28 .27

.29

.28

.27

.26

 

 

 

 

 

 

15

263

73

Cavity

4

.32

.30

.27

.26

.32

.29

.27

.26

.28

.27

.25

.28

.26

.25

.27

.26

.25

.24

 

 

20

255

 

5

.31 .27 .25 .24

.30

.27

.25

.23

.26

.25

.23

.26

.24

.23

.25

.24

.23

.22

 

 

 

 

 

 

25

233

107

Room

6

.29

.26

.23

.22

.28

.25

.23

.22

.25

.23

.21

.24

.23

.21

.24

.22

.21

.21

150

 

30

204

 

7

.27 .24 .21 .20

.27

.23

.21

.20

.23

.21

.20

.22

.21

.19

.22

.21

.19

.19

 

 

35

174

107

 

8

.26 .22 .20 .18

.25

.22

.20

.18

.21

.19

.18

.21

.19

.18

.21

.19

.18

.17

 

 

40

131

 

 

9

.24 .20 .18 .17

.24

.20

.18

.17 .20 .18 .16

.20 .18 .16 .19

.18 .16 .16

 

 

45

56

51

 

10

.23 .19 .17 .15 .22 .19 .17 .15 .18 .16 .15 .18 .16 .15 .18 .16 .15 .14

 

 

50

21

 

 

 

Determined in Accordance With Current IES Published Procedures

 

 

 

 

55

17

16

 

 

 

 

 

 

Luminaire Input Watts = 23.0

 

 

 

 

 

 

225

 

60

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30°

65

13

13

 

Zonal Lumens and Percentages

 

 

 

 

 

 

 

 

 

 

 

70

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zone

 

Lumens

% Lamp

%Luminaire

 

 

 

 

 

 

 

 

 

 

75

10

11

 

 

 

SC(Along) = 1.3, SC(Across) = 1.5

 

 

 

0-30

 

 

203

 

 

16.97

 

 

49.50

 

 

 

 

80

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0-40

 

 

311

 

 

25.92

 

 

75.59

 

 

 

 

 

 

 

 

 

 

 

85

9

10

 

 

 

 

 

 

 

 

 

Certified test report no. 3557FR

300

 

 

0-60

 

 

377

 

 

31.49

 

 

91.85

 

 

 

90

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Computed by LSI program **TEST-LITE**

 

 

 

0-90

 

 

411

 

 

34.29

 

100.00

 

 

Tested According to IES Procedures. Test Distance Exceeds Five

 

 

 

 

 

 

 

SC = 1.2

 

 

 

 

 

 

 

40-90

 

 

100

 

 

8.37

 

 

24.41

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Times the Greatest Luminous Opening of Luminaire.

 

60-90

 

 

33

 

 

2.79

 

 

8.15

 

 

Prepared For:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90-180

 

0

 

 

.00

 

 

.00

 

 

Lightolier

 

 

 

 

 

 

 

 

 

 

0-180

 

 

411

 

 

34.29

 

100.00

 

Fall River, MA

 

 

 

 

 

 

 

 

 

 

 

** Efficiency = 34.3% **

 

 

 

 

 

 

 

 

 

 

 

8091CL-D6AO1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

200

300

90° Calculite 6" Vetro Downlight, Cat.# 8091CL/D6A01 Opal Lens 32W Sylvania Dulux T/E Triple Tube. Lumen Rating = 2400 LMS.

Universal Ballast #C2642UNVBES(#1)

Candlepower Summary

 

Angle

Along

22.5

45

67.5

Across

LMS

 

0

460

460

460

460

460

 

60°

5

447

447

448

449

448

43

 

10

425

425

426

428

428

 

 

15

393

394

396

398

398

112

 

20

356

357

360

363

364

 

 

25

316

317

320

325

327

148

 

30

274

275

278

284

288

 

 

35

231

232

237

245

251

150

 

40

188

189

194

204

207

 

 

45

148

149

152

158

160

119

30°

50

111

111

111

112

113

 

 

55

50

50

51

53

54

58

 

60

42

42

43

44

44

 

 

65

36

37

37

37

38

37

Coefficients of Utilization

Ceiling

 

80%

 

 

70%

 

 

50%

 

 

30%

 

 

10%

 

Wall

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

RCR

 

 

Zonal Cavity Method - Effective Floor Reflectance = 20%

 

 

 

0

.36

.36 .36 .36

.35

.35 .35 .35

.33

.33

.33

.32

.32

.32

.31

.31

.31

.30

 

1

.33

.32

.31

.30

.33

.32

.31

.30

.30

.29

.29

.29

.28

.28

.28

.28

.27

.26

Ratio

2

.31

.29

.28

.26

.30

.29

.27

.26

.28

.26

.25

.27

.26

.25

.26

.25

.24

.24

3

.29

.27

.25

.23

.28

.26

.24

.23

.25

.24

.23

.25

.23

.22

.24

.23

.22

.21

 

Cavity

4

.27

.25

.22

.21

.27

.24

.22

.21

.23

.22

.20

.23

.21

.20

.22

.21

.20

.19

5

.26

.23

.20

.19

.25

.22

.20

.19

.22

.20

.18

.21

.20

.18

.21

.19

.18

.18

 

Room

6

.24

.21

.19

.17

.23

.20

.18

.17

.20

.18

.17

.20

.18

.17

.19

.18

.17

.16

7

.22

.19

.17

.15

.22

.19

.17

.15

.18 .16 .15

.18

.16

.15

.18

.16 .15 .14

 

 

8

.21

.18

.15

.14

.21

.17

.15

.14

.17 .15 .14

.17

.15

.14

.16

.15 .14 .13

 

9

.20

.16 .14 .13

.19

.16 .14 .13

.16 .14 .13

.15

.14

.12

.15

.14 .12 .12

 

10

.18 .15 .13 .11

.18 .15 .13 .11

.15 .13 .11

.14 .13 .11

.14 .12 .11 .11

 

 

Determined In Accordance With Current IES Published Procedures

 

 

 

 

 

 

 

 

Luminaire Input Watts = 38.0

 

 

 

 

 

 

400

70

32

32

32

33

33

 

75

28

28

28

28

28

30

80

25

25

25

25

25

 

85

23

23

23

23

23

25

90

20

20

20

21

20

 

Tested According to IES Procedures. Test Distance Exceeds Five

Times the Greatest Luminous Opening of Luminaire.

Zonal Lumens and Percentages

Zone

Lumens

% Lamp

%Luminaire

0-30

302

12.61

41.97

0-40

452

18.84

62.73

0-60

629

26.21

87.25

0-90

721

30.04

100.00

40-90

268

11.20

37.27

60-90

91

3.83

12.75

90-180

0

.00

.00

0-180

721

30.04

100.00

** Efficiency = 30.0% **

Certified test report no. 3517FR Computed by LSI program **TEST-LITE** SC = 1.0