Lightolier DPA2G12 Series Page 2 of, Photometry, Ordering Information, Options/Accessories

Models: DPA2G12 Series

1 2
Download 2 pages 58.92 Kb
Page 2
Image 2
Page 2 of 2

 

Deepcel Plus DPA2G12 Series

Page 2 of 2

2' x 2' Recessed Fluorescent, 3", 12 Cell Parabolic Louver

 

Static or Air/Return, 2 Lamp 6"U or 3–1-5/8"U T8 or 3 Twin Tube T5

Photometry

Model No. DPA2G12LP3FT120X3

G00048

DPA2G12LP3FT120X3

3 F40 / BIAX, EACH RATED 3150 LUMENS.

2X2 TROFFER WITH 3X4 12 CELL SEMI-SPECULAR: 2 COVER

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD PERFORMANCE MAY VARY FROM LABORATORY PERFORMANCE.

LER = FP - 58.3

IW - 99.5

BF - 0.88

 

 

 

 

 

 

 

 

 

 

 

Comparative yearly lighting energy cost per 1000 lumens = $4.12

 

 

 

 

 

 

coefficients of utilization — zonal cavity method

 

 

 

 

 

 

 

 

 

 

 

 

RF

 

 

 

20

 

 

 

 

20

 

 

 

 

 

 

20

 

 

 

RC

 

 

 

80

 

 

 

 

50

 

 

 

 

 

 

30

 

 

 

RW

 

70

 

50

 

30

 

50

30

 

10

 

 

50

30

10

 

 

1

 

78

 

75

 

73

 

71

69

 

68

 

 

68

67

66

 

ratio

2

 

72

 

68

 

64

 

64

62

 

59

 

 

62

60

58

 

3

 

67

 

61

 

57

 

58

55

 

52

 

 

57

53

51

 

 

 

 

 

 

 

 

 

 

cavity

4

 

62

 

55

 

50

 

53

49

 

46

 

 

51

48

45

 

5

 

58

 

50

 

45

 

48

44

 

40

 

 

47

43

40

 

room

6

 

54

 

46

 

40

 

44

39

 

36

 

 

43

39

36

 

7

 

50

 

42

 

36

 

40

36

 

32

 

 

39

35

32

 

 

8

 

47

 

38

 

33

 

37

32

 

29

 

 

36

32

29

 

 

9

 

44

 

35

 

30

 

34

30

 

26

 

 

33

29

26

 

 

10

 

41

 

33

 

28

 

32

27

 

24

 

 

31

27

24

 

visual comfort probability (VCP) average 100 fc; reflectances 80/50/20

 

 

 

 

 

 

 

room size

 

 

 

 

ceiling height

 

 

 

 

 

 

ceiling height

 

 

 

W

 

 

L

 

8.5

10.0

13.0

 

16.0

 

 

 

8.5

10.0

13.0

 

16.0

20

 

 

20

 

 

71

63

55

 

55

 

 

 

73

65

63

 

61

20

 

 

30

 

 

74

66

59

 

53

 

 

 

75

67

62

 

58

20

 

 

40

 

 

76

69

63

 

56

 

 

 

77

69

65

 

59

 

20

 

 

60

 

 

78

71

66

 

60

 

 

 

78

72

68

 

62

30

 

 

20

 

 

76

68

59

 

57

 

 

 

78

70

65

 

62

30

 

 

30

 

 

78

70

62

 

55

 

 

 

79

71

64

 

58

30

 

 

40

 

 

79

72

65

 

58

 

 

 

80

73

67

 

59

30

 

 

60

 

 

80

74

68

 

61

 

 

 

81

75

69

 

62

 

30

 

 

80

 

lengthwise

82

76

70

 

64

 

crosswise

 

81

76

71

 

64

40

 

 

40

 

81

75

69

 

60

 

 

82

76

70

 

61

40

 

 

20

 

 

78

71

63

 

60

 

 

 

80

73

69

 

63

40

 

 

30

 

luminaries

80

73

66

 

57

 

luminaries

 

81

74

68

 

60

40

 

 

60

 

82

77

71

 

63

 

 

82

77

72

 

63

40

 

 

80

 

 

83

78

73

 

65

 

 

 

83

78

73

 

65

 

40

 

 

100

 

 

84

79

74

 

67

 

 

 

83

79

75

 

67

60

 

 

30

 

 

81

75

69

 

61

 

 

 

82

76

71

 

63

60

 

 

40

 

 

82

77

71

 

63

 

 

 

83

78

72

 

64

60

 

 

60

 

 

83

78

73

 

65

 

 

 

83

78

74

 

66

 

 

 

 

 

 

 

60

 

 

80

 

 

84

80

75

 

67

 

 

 

83

79

75

 

68

 

60

 

 

100

 

 

85

81

76

 

69

 

 

 

84

80

76

 

69

100

 

 

40

 

 

83

78

74

 

67

 

 

 

83

78

75

 

67

100

 

 

60

 

 

84

79

75

 

69

 

 

 

84

79

76

 

69

100

 

 

80

 

 

85

81

77

 

71

 

 

 

84

80

77

 

71

 

100

 

 

100

 

 

86

82

78

 

72

 

 

 

85

81

78

 

72

Ordering Information

Explanation of Catalog Number. Example: DPA2G12LP3FT120X3CP

2

 

 

 

 

12

 

 

 

 

 

 

 

 

Deepcel Plus

Parabolic:

Pre-anodized

aluminum

louver

Body Style:

Fixture

Ceiling Type:

Number of

Louver Finish:

Reflector:

A=Air Supply

Width

G= Grid

Cells:

L = Low

S = Single "V"

S=Static

 

(lay-in T bar)

12=3 rows

iridescence

Reflector

 

 

F= Flanged (over

of 4

Semi-specular

(2 Lamp)

 

 

lap) Z spline and

 

(standard)

P = Dual "V"

 

 

plaster frame

 

P =Low

Reflectors

Lamp

 

Options:

Quantity

 

Add appropriate

2 or 3 Lamp

Voltage:

suffix to catalog no.,

 

120, 277 or

ie: (CP)

 

UNV=120-277

 

DP

DY

ND

 

T= Slot grid or

iridescence

(3 Lamps)

Standard Deepcel

two-directional

Specular

 

concealed T

W =White Baked

 

 

(see options)

Enamel

 

For NYC Code – I.B.E.W. Manufactured

For NYC Code – Local 3 Manufactured 5½" Deep Body

Lamp Type/

Fixture Length:

2U = T8 1-5/8"U Lamp (Nominal 24")

FT = Twin Tube T5 (Nominal 24")

6U = 6"U Lamp T8

2 Lamp Only (Nominal 24")

Note: For Linear T5 Lamp option, consult factory

 

Ballast Type:

 

 

 

<20THD <10THD

1-2

Lamp Elec. T8

SO *

HI *

1-3

Lamp Elec. T8

O3 *

H3 *

LOL T8 Dimming

PS

1-2

Lamp Elec. TT5

SB *

IB *

 

(40 watt)

 

I3 *

1-3

Lamp Elec. TT5

X3 *

 

(40 watt)

PB

-

LOL TT5 Dimming

*Instant Start Standard

Other dimming options. Consult factory.

NOTE:

I3

For TT5 UNV, you must use IB,

Ballast Code.

For T8 UNV, you must use HI, H3 Ballast Code.

Options/Accessories

Plaster Frame: Catalog Number: PF22.

Continuous Row Installation: For F type fixtures, half width flanges are required between

fixtures. Order Catalog Number: 2FC TRIM CSP (each joint).

Radio Interference Filter: To order one RIF per fixture; SUFFIX: R. To order one RIF per ballast;

SUFFIX: B.

Electrical Wiring Options: Consult factory.

Air Closure Strip: SUFFIX: ACS2 (factory installed).

Drywall Kit: Order Catalog Number: FK92X2. (Request Folio OA30-10 Rev. A).

Chicago Plenum: SUFFIX: CP.

Specifications

Performance: In an installation of 3 lamp 40W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .75. To prevent glare the VCP shall be not less than 83 either lengthwise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 2394 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 62.2%.

Air Handling (DPA only) side air passages for air supply or air return. Supply air is discharged vertically. Optional side closure strips. Air return is also provided through the lamp compartment through fixture body ends.

Specifications (continued)

Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing is ribbed for rigidity with side rails hemmed over and housing ends turned-in for safe handling. Louver is pre-anodized aluminum (Coilzak® or equal.

Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. Louver–low iridescence semi- specular anodized vertical grain aliminum reflector sheet is standard.

Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is with- in 3" of ballast, use wire suitable for at least 90°.

Labels: I.B.E.W. UL and ULc Listed.

Job Information Type:

Lightolier a Genlyte companywww.lightolier.com Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2007 a Genlyte company

Section 2/Folio G51-30 Rev. A

Page 2
Image 2
Lightolier DPA2G12 Series Page 2 of, Photometry, Ordering Information, Options/Accessories, Specifications, Dp Dy Nd