Lightolier DPA2G12LS232 Page 2 of, Photometry, Ordering Information, Options/Accessories, Type

Models: DPA2G12LS232

1 2
Download 2 pages 51.55 Kb
Page 2
Image 2
Deepcel Plus DPA2G12LS232

Deepcel Plus DPA2G12LS232

Page 2 of 2

Photometry

Model No. DPA2G12LS232120SO

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD PERFORMANCE MAY VARY FROM LABORATORY PERFORMANCE.

2' x 4' Recessed Fluorescent, 3", 12 Cell Parabolic Louver Static or Air/Return, 2 Lamp, T8 or T5

LER = FP - 64.4 IW - 61.6 BF - 0.87

Comparative yearly lighting energy cost per 1000 lumens = $3.73

coefficients of utilization — zonal cavity method

 

RF

 

20

 

 

20

 

 

20

 

 

RC

 

80

 

 

50

 

 

30

 

 

RW

70

50

30

50

30

10

50

30

10

 

1

89

85

83

80

78

76

77

75

74

ratio

2

81

76

71

71

68

64

69

66

63

3

74

67

61

63

59

55

61

57

54

 

cavity

4

69

59

53

56

51

47

55

50

46

5

63

53

46

50

45

40

49

44

40

room

6

58

48

41

45

40

35

44

39

35

7

53

43

36

41

35

31

40

35

31

 

8

50

39

32

37

32

28

36

31

27

 

9

46

36

29

34

29

25

33

28

25

 

10

43

33

27

32

26

22

31

26

22

visual comfort probability (VCP) average 100 fc; reflectances 80/50/20

room size

 

 

 

 

ceiling height

 

 

 

 

ceiling height

 

W

L

 

8.5

10.0

13.0

16.0

 

 

8.5

10.0

13.0

16.0

20

20

 

 

80

75

76

86

 

 

76

71

71

77

20

30

 

 

83

78

75

76

 

 

80

74

70

72

20

40

 

 

83

81

79

77

 

 

80

77

73

72

20

60

 

 

83

81

81

80

 

 

80

77

76

74

30

20

 

 

83

78

75

82

 

 

81

75

71

75

30

30

 

 

86

81

75

73

 

 

84

77

71

71

30

40

 

 

86

84

78

74

 

 

84

80

73

70

30

60

 

 

86

84

81

77

 

 

84

80

76

73

30

80

 

lengthwise

86

84

81

77

 

crosswise

84

80

76

76

40

40

 

86

85

80

74

 

84

81

76

71

40

20

 

 

83

82

78

81

 

 

81

77

75

76

40

30

 

luminaries

86

83

77

73

 

luminaries

84

79

74

71

40

60

 

86

85

83

77

 

84

81

79

73

40

80

 

 

86

85

83

77

 

 

84

80

79

75

40

100

 

 

86

85

83

77

 

 

84

80

78

75

60

30

 

 

86

84

79

75

 

 

84

79

76

74

60

40

 

 

86

85

82

76

 

 

84

81

78

73

60

60

 

 

86

85

84

78

 

 

84

80

80

75

 

 

60

80

 

 

86

85

84

79

 

 

84

80

80

76

60

100

 

 

86

85

84

79

 

 

84

80

80

76

100

40

 

 

86

85

82

78

 

 

84

80

78

74

100

60

 

 

86

85

84

80

 

 

84

80

80

77

100

80

 

 

86

85

84

81

 

 

84

80

80

77

100

100

 

 

86

85

84

81

 

 

84

80

80

77

Ordering Information

Explanation of Catalog Number. Example: DPA2G12LS232120SOCP

2

 

 

 

 

 

 

 

 

 

 

S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Deepcel Plus

Parabolic:

Pre-anodized

aluminum

louver

DP

DY

ND

 

 

 

 

 

Number of

Louver Finish:

Single "V"

Body Style:

 

Fixture

Ceiling Type:

A=Air Supply

 

Width

G= Grid

Cells:

L = Low

Reflector

S=Static

 

 

(lay-in T bar)

12=2 rows

iridescence

 

 

 

 

 

 

 

 

F= Flanged (over

of 6

Semi-specular

 

 

 

 

 

lap) Z spline and

18=3 rows

(standard)

 

 

 

 

 

plaster frame

of 6

P =Low

 

 

 

 

 

T= Slot grid or

24=3 rows

iridescence

 

Standard Deepcel

 

two-directional

of 8

Specular

 

 

concealed T

32=4 rows W =White Baked

 

 

 

 

 

(see options)

of 8

Enamel

 

For NYC Code – I.B.E.W. Manufactured

For NYC Code – Local 3 Manufactured 5½" Deep Body

Lamp

Quantity

Lamp Type/

Fixture Length:

32=32W T8

28=28W T5

54=54W T5 (Nominal 48")

 

 

 

 

 

 

 

 

 

 

Options:

Voltage:

 

Add appropriate

 

suffix to catalog no.,

120, 277 or

 

 

ie: (CP)

UNV=120-277

 

 

 

 

 

Ballast

Type:

 

 

 

 

 

<20THD <10THD

1-2

Lamp Elec. T8

SO *

HI

*

1-2

Lamp 28W Elec. T5

PI

1-2

Lamp 28W Elec. T5

PG ††

1-2

Lamp 54W Elec. T5

PG ††

LOL T8 Dimming

PS

 

Other dimming options. Consult factory.

*Instant Start Standard

†Instant Start (120, 277 or UNV) ††Program Rapid Start (UNV only)

NOTE:I

For T8 UNV, you must use H Ballast Code.

Options/Accessories

Plaster Frame: Catalog Number: PF24.

Continuous Row Installation: For F type fixtures, half width flanges are required between

fixtures. Order Catalog Number: 2FC TRIM CSP (each joint).

Radio Interference Filter: To order one RIF per fixture; SUFFIX: R. To order one RIF per ballast;

SUFFIX: B.

Electrical Wiring Options: Consult factory.

Air Closure Strip: SUFFIX: ACS4 (factory installed).

Drywall Kit: Order Catalog Number: FK92X4. (Request Folio OA30-10 Rev. A).

Chicago Plenum: SUFFIX: CP.

Specifications

Performance: In an installation of 2 lamp 32W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .85. To prevent glare the VCP shall be not less than 75 either lengthwise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 1606 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 72.0%.

Air Handling (DPA only) side air pasaages for air supply or air return. Supply air is discharged vertically. Optional side closure strips. Air return is also provided through the lamp compartment through fixture body ends.

Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing is ribbed for rigidity with side rails hemmed over and housing ends turned-in for safe handling. Louver is pre-anodized aluminum (Coilzak® or equal.

Specifications (continued)

Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. Louver–low iridescence semi- specular anodized vertical grain aliminum reflector sheet is standard.

Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is with- in 3" of ballast, use wire suitable for at least 90°.

Labels: I.B.E.W. UL and ULc Listed.

 

Job Information

Type:

 

 

 

Lightolier a Genlyte companywww.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2007 a Genlyte company

Section 2/Folio G51-40 Rev. A

Page 2
Image 2
Lightolier DPA2G12LS232 Page 2 of, Photometry, Ordering Information, Options/Accessories, Specifications, Dp Dy Nd, Type