Photometry

Model No. DPA2G9LP3FT120X3

G00049

DPA2G9LP3FT120X3

3 F40/BIAX. EACH RATED 3150 LUMENS.

2X2 TROFFER WITH 3X3 9 CELL SEMI-SPECULAR LOUVER.

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD PERFORMANCE MAY VARY FROM LABORATORY PERFORMANCE.

2' x 2' Recessed Fluorescent, 3", 9 Cell Parabolic Louver Static or Air/Return, 3 Lamp Twin Tube T5

LER = FP - 59.9

IW - 100 BF - 0.88

 

 

 

 

 

 

 

 

 

 

 

Comparative yearly lighting energy cost per 1000 lumens = $4.00

 

 

 

 

 

 

coefficients of utilization — zonal cavity method

 

 

 

 

 

 

 

 

 

 

 

 

RF

 

 

 

20

 

 

 

 

20

 

 

 

 

 

 

20

 

 

 

RC

 

 

 

80

 

 

 

 

50

 

 

 

 

 

 

30

 

 

 

RW

 

70

 

50

 

30

 

50

30

 

10

 

 

50

30

10

 

 

1

 

80

 

78

 

75

 

73

71

 

70

 

 

70

69

68

 

ratio

2

 

75

 

70

 

66

 

66

63

 

61

 

 

64

61

59

 

3

 

69

 

63

 

58

 

60

56

 

53

 

 

58

55

52

 

 

 

 

 

 

 

 

 

 

cavity

4

 

64

 

57

 

51

 

54

50

 

46

 

 

52

49

46

 

5

 

59

 

51

 

46

 

49

44

 

41

 

 

48

44

40

 

room

6

 

55

 

47

 

41

 

45

40

 

36

 

 

44

39

36

 

7

 

51

 

43

 

37

 

41

36

 

33

 

 

40

36

32

 

 

8

 

48

 

39

 

33

 

38

33

 

29

 

 

37

32

29

 

 

9

 

45

 

36

 

30

 

35

30

 

27

 

 

34

30

26

 

 

10

 

42

 

33

 

28

 

32

27

 

24

 

 

31

27

24

 

visual comfort probability (VCP) average 100 fc; reflectances 80/50/20

 

 

 

 

 

 

 

room size

 

 

 

 

ceiling height

 

 

 

 

 

 

ceiling height

 

 

 

W

 

 

L

 

8.5

10.0

13.0

 

16.0

 

 

 

8.5

10.0

13.0

 

16.0

20

 

 

20

 

 

62

55

49

 

53

 

 

 

70

63

63

 

61

20

 

 

30

 

 

65

59

50

 

46

 

 

 

72

66

61

 

57

20

 

 

40

 

 

68

62

55

 

48

 

 

 

74

68

64

 

59

 

20

 

 

60

 

 

70

64

58

 

52

 

 

 

76

70

67

 

61

30

 

 

20

 

 

68

61

53

 

55

 

 

 

75

67

63

 

61

30

 

 

30

 

 

70

64

54

 

48

 

 

 

76

69

62

 

57

30

 

 

40

 

 

73

66

58

 

50

 

 

 

78

71

65

 

58

30

 

 

60

 

 

74

68

61

 

53

 

 

 

79

73

67

 

61

 

30

 

 

80

 

lengthwise

76

70

63

 

56

 

crosswise

 

80

74

69

 

63

40

 

 

40

 

75

69

62

 

53

 

 

79

74

68

 

59

40

 

 

20

 

 

71

66

58

 

58

 

 

 

77

71

67

 

62

40

 

 

30

 

luminaries

73

67

58

 

51

 

luminaries

 

78

73

65

 

58

40

 

 

60

 

77

71

64

 

56

 

 

80

75

70

 

61

40

 

 

80

 

 

78

73

66

 

59

 

 

 

81

77

71

 

64

 

40

 

 

100

 

 

79

74

68

 

61

 

 

 

82

78

73

 

66

60

 

 

30

 

 

75

70

62

 

54

 

 

 

80

75

69

 

60

60

 

 

40

 

 

77

72

65

 

56

 

 

 

81

76

70

 

61

60

 

 

60

 

 

78

73

67

 

58

 

 

 

82

77

72

 

63

 

 

 

 

 

 

 

60

 

 

80

 

 

79

75

69

 

61

 

 

 

82

78

73

 

65

 

60

 

 

100

 

 

80

76

71

 

63

 

 

 

83

79

74

 

67

100

 

 

40

 

 

78

73

68

 

60

 

 

 

82

77

73

 

65

100

 

 

60

 

 

79

75

70

 

62

 

 

 

82

78

74

 

67

100

 

 

80

 

 

80

76

72

 

65

 

 

 

83

79

76

 

69

 

100

 

 

100

 

 

81

78

73

 

67

 

 

 

84

80

77

 

70

Ordering Information

Explanation of Catalog Number. Example: DPA2G9LP3FT120X3CP

2

 

 

 

 

9

 

 

 

 

P

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

FT

 

 

 

 

 

Deepcel Plus

3" Parabolic:

Pre-anodized

aluminum

louver

DP

DY

ND

 

 

 

 

 

Number of

Louver Finish:

Dual "V"

Body Style:

 

Fixture

Ceiling Type:

A=Air Supply

 

Width

G= Grid

Cells:

L = Low

Reflectors

S=Static

 

 

(lay-in T bar)

9=3 rows of 3

iridescence

 

 

 

 

 

 

 

 

F= Flanged (over

 

Semi-specular

 

 

 

 

 

lap) Z spline and

 

(standard)

 

 

 

 

 

plaster frame

 

P =Low

 

 

 

 

 

T= Slot grid or

 

iridescence

 

Standard Deepcel

 

two-directional

 

Specular

 

 

concealed T

 

W =White Baked

 

 

 

 

 

(see options)

 

Enamel

 

For NYC Code – I.B.E.W. Manufactured

For NYC Code – Local 3 Manufactured 5½" Deep Body

 

 

 

 

 

 

 

 

Lamp

Lamp Type/

 

 

 

Options:

Quantity

Fixture Length:

 

 

Add appropriate

 

Twin Tube T5

Voltage:

 

suffix to catalog no.,

 

(Nominal 24")

120, 277 or

 

 

ie: (CP)

 

Note: For Linear

UNV=120-277

 

 

 

 

 

 

T5 Lamp option,

 

 

 

 

 

 

 

Ballast Type:

 

 

 

 

consult factory

 

 

 

 

 

 

<20THD <10THD

 

 

 

 

 

 

1 & 2 Lamp Elec. TT5

SB *

I

B *

 

 

(40-watt)

 

 

 

 

 

1-3 Lamp Elec. TT5

X3 *

I

3 *

 

 

(40-watt)

 

 

 

 

 

LOL TT5 Dimming

PB

 

 

 

*Instant Start Standard

 

 

 

 

 

 

Other dimming options. Consult factory.

 

 

NOTE:

 

I3

 

 

 

 

For TT5 UNV, you must use IB,

 

 

Ballast Code.

Options/Accessories

Plaster Frame: Catalog Number: PF22.

Continuous Row Installation: For F type fixtures, half width flanges are required between

fixtures. Order Catalog Number: 2FC TRIM CSP (each joint).

Radio Interference Filter: To order one RIF per fixture; SUFFIX: R. To order one RIF per ballast;

SUFFIX: B.

Electrical Wiring Options: Consult factory.

Air Closure Strip: SUFFIX: ACS2 (factory installed).

Drywall Kit: Order Catalog Number: FK92X2. (Request Folio OA30-10 Rev. A).

Chicago Plenum: SUFFIX: CP.

Specifications

Performance: In an installation of 3 lamp 40W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .78. To prevent glare the VCP shall be not less than 58 either lengthwise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 2943 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 63.4%.

Air Handling (DPA only) side air pasaages for air supply or air return. Supply air is discharged vertically. Optional side closure strips. Air return is also provided through the lamp compartment through fixture body ends.

Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing is ribbed for rigidity with side rails hemmed over and housing ends turned-in for safe handling. Louver is pre-anodized aluminum (Coilzak® or equal.

Specifications (continued)

Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. Louver–low iridescence semi- specular anodized vertical grain aliminum reflector sheet is standard.

Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is with- in 3" of ballast, use wire suitable for at least 90°.

Labels: I.B.E.W. UL and ULc Listed.

 

Job Information

Type:

 

 

 

Lightolier a Genlyte companywww.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2007 a Genlyte company

Section 2/Folio G51-24 Rev. A

Page 2
Image 2
Lightolier DPA2G9LP3FT Page 2 of, Photometry, Ordering Information, Options/Accessories, Specifications, Dp Dy Nd, Type