PHOTOMETRY

MODEL NO. DPB2S18LS332120O3 coefficients of utilization — zonal cavity method

 

RF

 

20

 

 

20

 

 

20

 

 

RC

 

80

 

 

50

 

 

30

 

 

RW

70

50

30

50

30

10

50

30

10

 

1

78

75

73

71

69

68

68

67

65

ratio

2

72

68

64

64

61

59

62

60

58

3

67

61

56

58

54

51

56

53

51

cavity

4

62

55

50

52

48

45

51

47

44

5

57

49

43

47

42

39

45

41

38

 

room

6

52

44

38

42

37

34

41

37

34

7

48

39

34

38

33

29

37

33

29

 

8

44

35

30

34

29

25

33

29

25

 

9

41

31

26

30

25

22

29

25

22

 

10

38

28

23

27

23

19

27

22

19

visual comfort probability

room size

 

 

 

 

ceiling height

 

 

 

 

ceiling height

 

W

L

 

8.5

10.0

13.0

16.0

 

 

8.5

10.0

13.0

16.0

20

20

 

 

75

69

69

77

 

 

77

73

71

78

20

30

 

 

78

73

67

67

 

 

80

76

72

69

20

40

 

 

80

76

71

68

 

 

83

79

76

72

20

60

 

 

80

76

74

71

 

 

84

81

79

75

30

20

 

 

80

74

69

76

 

 

82

76

71

76

30

30

 

 

83

77

68

66

 

 

84

79

73

68

30

40

 

 

84

80

72

67

 

 

86

81

76

70

30

60

 

 

84

80

75

70

 

 

87

83

79

73

30

80

 

lengthwise

84

80

75

71

 

crosswise

88

84

80

76

40

40

 

85

82

75

68

 

87

84

78

71

40

20

 

 

80

77

73

76

 

 

82

79

74

76

40

30

 

luminaries

84

79

72

67

 

luminaries

85

82

75

68

40

60

 

86

82

78

71

 

88

85

81

73

 

 

 

 

40

80

 

 

86

82

78

72

 

 

89

86

82

76

40

100

 

 

86

82

78

72

 

 

89

86

84

78

60

30

 

 

84

79

74

70

 

 

85

82

77

70

60

40

 

 

86

82

77

70

 

 

87

84

80

73

60

60

 

 

86

83

80

73

 

 

88

86

82

75

 

 

60

80

 

 

86

84

80

75

 

 

89

87

84

77

60

100

 

 

86

84

80

75

 

 

89

87

84

79

100

40

 

 

86

82

77

72

 

 

87

84

80

75

100

60

 

 

86

83

80

75

 

 

88

86

83

77

100

80

 

 

86

84

81

77

 

 

89

87

84

79

100

100

 

 

86

83

81

77

 

 

89

87

85

81

ORDERING INFORMATION Explanation of Catalog Number. Example: DPB2S18LS332120O3GLR

DP

 

 

B

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

DEEPCELL

 

 

 

 

 

FIXTURE

 

PARABOLIC:

 

 

 

 

 

WIDTH

 

Pre-anodized

 

 

 

 

 

 

 

 

Aluminum

 

 

 

 

 

 

 

 

Louver

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BODY STYLE:

 

 

 

 

 

 

 

 

Surface Box

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Consult factory for availability of louver finishes.

S

 

 

 

 

 

 

 

 

S

 

 

 

 

 

 

 

 

 

 

 

 

 

NUMBER OF

 

BALLAST

 

 

 

CELLS

 

COVER

 

 

 

18 or 24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CEILING

 

 

 

 

LOUVER FINISH*:

 

 

TYPE:

 

L=

Low-iridescence semi-specular

S=Surface

 

P=

(standard)

 

 

 

 

 

Low-iridescence specular

 

 

W= White Paint

3

LAMP

 

VOLTAGE:

 

 

OPTIONS:

QUANTITY:

 

120 or 277

 

Add appropriate suffix

(By Others)

 

 

 

to catalog no., ie: (GLR)

3=3 Lamp

 

BALLAST TYPE:

 

 

 

 

 

 

1 & 2 Lamp Mag.

LE

 

 

 

 

 

<20THD

<10THD

LAMP/

 

 

1 & 2 Lamp Elec. T8

SO*

HI*

FIXTURE LENGTH:

1-3 Lamp Elec. T8

O3*

H3*

32=T88

LOL Dimming T8

PS

34=T12

*Instant Start Standard

 

 

(Nominal 48")

 

 

Other dimming options. Consult factory.

OPTIONS & ACCESSORIES

STEM AND CANOPY SETS: Suspends fixture 6", 12", 18" or 24" from surface.

(Four per fixture is recommended.) Catalog Number: ASC6 CSP (6"), ASC12 CSP (12"), ASC18 CSP (18"), ASC24 CSP (24")

FUSING: Internal fast-blow fusing.

SUFFIX: GLR.

Internal slow-blow fusing.

SUFFIX: GMF.

RADIO INTERFERENCE FILTER 120 or 277 volt, 50 or 60 Hz. One per fixture is standard. SUFFIX: RF.

ELECTRICAL/WIRING OPTIONS Consult factory.

SPECIFICATIONS

PERFORMANCE: In an installation of 3 lamp 32W luminaires in a room cavity ratio of 1, with a reflectance of 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .75. To prevent glare the VCP shall be not less than 85 either lengthwise or cross wise (at 100fc level) and the average brightness at 65° shall not exceed 610 footlamberts. To control veiling reflections, luminaire output in the 30°-90° zone shall be not less than 69%.

SPECIFICATIONS (continued)

MATERIALS: Chassis parts are die-formed 20 gauge cold rolled steel, stud- welded for rigidity with all seams finished smooth.

LOUVER: pre-anodized aluminum (Coilzak® or equal).

STANDARD FINISH: Louver—low iridescence, semi-specularpre-anodized vertical grain reflector sheet. Cavity—white baked acrylic enamel minimum 86% reflectance. Phosphate undercoating. Chassis exterior—white baked acrylic enamel.

ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

LABELS: I.B.E.W./UL and C-UL.

Job Information

 

Type:

Lightolier a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902

Page 2
Image 2
Lightolier DPB2S18LS332 dimensions Photometry, Options & Accessories, Specifications, Job Information