Lightolier DPB2S9LS3FT/2U Page 2 of, Photometry, Options & Accessories, Specifications, Type

Models: DPB2S9LS3FT/2U

1 2
Download 2 pages 25.52 Kb
Page 2
Image 2
Page 2 of 2
Section 2A/Folio G50-86 REV. B

DEEPCELL SURFACE DPB2S9LS3FT/2U OR 17

Page 2 of 2

PHOTOMETRY

G90051

DPB2S9LS3FT120X3

2' x 2' SURFACE FLUORESCENT, 3" TYPE, 9 CELL PARABOLIC LOUVER 3 LAMP TWIN TUBE T5, 1-5/8" U LAMP OR 2' LAMP T8

MODEL NO. DPB2S9LS3FT120X3 coefficients of utilization — zonal cavity method

 

RF

 

20

 

 

20

 

 

20

 

 

RC

 

80

 

 

50

 

 

30

 

 

RW

70

50

30

50

30

10

50

30

10

ratio

1

69

67

65

63

61

60

60

59

58

3

60

55

51

52

49

47

51

48

46

 

2

64

60

57

57

55

53

55

53

52

cavity

4

55

50

45

47

44

41

46

43

41

5

51

45

40

43

39

36

42

38

36

room

6

47

40

36

39

35

32

38

34

32

8

40

33

28

32

27

24

31

27

24

 

7

44

36

32

35

31

28

34

31

28

 

9

37

29

25

28

24

21

28

24

21

 

10

34

27

22

26

22

19

25

21

19

visual comfort probability

room size

 

 

 

 

ceiling height

 

 

 

 

ceiling height

 

W

L

 

8.5

10.0

13.0

16.0

 

 

8.5

10.0

13.0

16.0

20

20

 

 

71

62

58

62

 

 

75

67

63

71

20

30

 

 

75

67

61

55

 

 

78

72

68

59

20

40

 

 

75

71

66

59

 

 

81

75

72

64

20

60

 

 

75

71

70

63

 

 

83

77

75

68

30

20

 

 

75

69

60

63

 

 

80

73

83

69

30

30

 

 

79

73

63

56

 

 

83

70

68

59

30

40

 

 

79

76

68

60

 

 

85

79

72

63

30

60

 

lengthwise

79

76

71

64

 

crosswise

86

80

75

67

40

40

 

79

77

72

61

 

85

79

75

64

30

80

 

 

79

76

71

64

 

 

85

80

75

70

40

20

 

 

75

69

65

64

 

 

80

73

68

69

40

30

 

 

79

74

68

58

 

 

83

77

72

60

40

60

 

luminaries

79

77

75

65

 

luminaries

85

80

78

68

40

80

 

79

77

75

65

 

85

80

78

70

40

100

 

 

79

77

75

65

 

 

85

80

78

70

60

30

 

 

79

74

69

61

 

 

83

77

74

63

60

40

 

 

79

77

73

65

 

 

84

80

78

67

60

60

 

 

79

77

77

68

 

 

85

80

80

70

 

 

60

80

 

 

79

77

77

69

 

 

85

80

80

73

60

100

 

 

79

77

77

69

 

 

85

80

80

73

100

40

 

 

79

77

73

65

 

 

84

80

78

67

100

60

 

 

79

77

77

69

 

 

85

80

80

71

100

80

 

 

80

77

76

70

 

 

85

80

80

73

100

100

 

 

80

77

76

70

 

 

85

80

80

74

ORDERING INFORMATION Explanation of Catalog Number. Example: DPB2S9LS3FT120X3GLR

DP

 

B

 

2

 

S

 

 

 

 

 

S

3

 

 

 

 

 

 

 

 

 

 

 

 

 

DEEPCELL

 

 

FIXTURE

 

 

NUMBER OF

 

BALLAST

PARABOLIC:

 

 

WIDTH

 

 

CELLS

 

COVER

Pre-anodized

 

 

 

 

 

 

9 or 12

 

 

 

Aluminum

 

 

 

 

 

 

 

 

 

 

 

Louver

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BODY STYLE:

 

 

CEILING

 

LOUVER FINISH*:

 

 

 

 

Surface Box

 

 

TYPE:

L= Low-iridescence semi-specular

 

 

 

 

 

 

S=Surface

 

(standard)

 

 

P= Low-iridescence specular

W=White Paint

*Consult factory for availability of louver finishes.

LAMP

QUANTITY:

(By Others)

3=3 Lamp

LAMP/

FIXTURE LENGTH:

2U=T8, 1-5/8" U Lamp

FT=Twin Tube T5

17=T8, 2' Lamp

(Nominal 24")

VOLTAGE:

 

OPTIONS:

120 or 277

Add appropriate suffix

 

to catalog no., ie: (GLR)

BALLAST TYPE:

 

 

<20THD <10THD

1 & 2 Elec. T8

SO*

HI*

1-3 Lamp Elec. T8

O3*

H3*

1 & 2 Lamp Elec. T5

SB*

IB*

1-3 Lamp Elec. T5

X3*

I3*

LOL Dimming T8

PS

LOL Dimming T5

PB

*Instant Start Standard

Other dimming options. Consult factory.

OPTIONS & ACCESSORIES

STEM AND CANOPY SETS: Suspends fixture 6", 12", 18" or 24" from surface.

(Four per fixture is recommended.) Catalog Number: ASC6 CSP (6"), ASC12 CSP (12"), ASC18 CSP (18"), ASC24 CSP (24")

FUSING: Internal fast-blow fusing.

SUFFIX: GLR.

Internal slow-blow fusing.

SUFFIX: GMF.

RADIO INTERFERENCE FILTER 120 or 277 volt, 50 or 60 Hz. One per fixture is standard. SUFFIX: RF.

ELECTRICAL/WIRING OPTIONS Consult factory.

SPECIFICATIONS

PERFORMANCE: In an installation of 3U lamp 40W luminaires in a room cavi- ty ratio of 1, with a reflectance of 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .67. To prevent glare the VCP shall be not less than 79 either lengthwise or cross wise (at 100fc level) and the average brightness at 65° shall not exceed 682 footlamberts. To control veiling reflections, luminaire output in the 30°-90° zone shall be not less than 64%.

MATERIALS: Chassis parts are die-formed 20 gauge cold rolled steel, stud-

SPECIFICATIONS (continued)

welded for rigidity with all seams finished smooth. LOUVER: pre-anodized aluminum (Coilzak® or equal).

STANDARD FINISH: Louver—low iridescence, semi-specularpre-anodized vertical grain reflector sheet. Cavity—white baked acrylic enamel minimum 86% reflectance. Phosphate undercoating. Chassis exterior—white baked acrylic enamel.

ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

LABELS: I.B.E.W./UL and C-UL.

Job Information

 

Type:

 

 

 

Lightolier a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902

Page 2
Image 2
Lightolier DPB2S9LS3FT/2U Page 2 of, Photometry, Options & Accessories, Specifications, SPECIFICATIONS continued, Type