Lightolier EC1-2 Page 2 of, Control Ordering Information, Ordering Instructions, ECS End Sets

Models: EC1-2

1 3
Download 3 pages 57.44 Kb
Page 2
Image 2
Lighting Systems EC1-2

Lighting Systems EC1-2

Page 2 of 3

Control Ordering Information

Energos Control System 2-Light T8 per 4' (121.92cm) (Nominal) Louver

Family

Series

Lamping &

 

 

Distribution

EC

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

2 = 2 lamp,

 

 

 

 

 

 

open top

 

 

 

 

 

 

5 = 2 lamp,

 

 

 

 

 

 

slotted top

 

 

 

 

 

 

 

 

 

 

 

reflector

Ballast

See Chart on Page 3

Lamp

See Chart on Page 3

Shielding

P

P = Parabolic Louver

 

Length

 

 

Voltage

 

Finish

Options

 

 

 

 

 

 

 

 

 

 

 

 

(Blank)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 = 4' (121.92cm)

6 = 120

Vac Master

 

A = Aluminum

 

4 = 4 through wires

 

8 = 8' (243.84cm)

7

= 277

Vac Master

 

W=White

 

5 = 5 through wires

 

 

 

8

= 120

Vac Slave

 

 

 

 

6 = 6 through wires

 

 

 

9

= 277

Vac Slave

 

 

 

 

D = Dual Switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T = Tandem Switch

 

 

 

 

 

 

 

 

 

 

 

 

E = Emergency

Ordering Instructions

End Cap ECS Systems

1.Order Master 4' (121.92cm) or 8' (243.84cm) ECS Module.

2.Order Power Feed End Set.

Continuous Row Mounted ECS Systems:

1.Determine run length

2.Order a minimum of one master per run. Please see Application Guide for master requirements on runs that exceed 16' (487.68cm).

3.Order the required remaining Master and Slave modules to complete the run.

4.Order Power Feed End Set.

5.Order one CABLE ASSEMBLY per MODULE minus one per run.

6.Order additional Single Cable & Cord Sets for every Master Module in run.

ECS Sensor Sample Runs

4' Run: 4' (121.92cm) Master Module with Single Sensor End Set.

8' Run: 8' (243.84cm) Master Module and standard Energos End Set.

8' Run: 8' (243.84cm) Master Module and Dual Sensor End Set.

12' Run:8' (243.84cm) Master Module, 4' (121.92cm) Slave Module, Dual Sensor End Set, and Intermediate Cable Assembly.

ECS End Sets

Single Sensor

Dual Sensor

Single Cable &

End Set EC1SE36W

End Set EC1DE36W

Power Cord EGCC36

Single Sensor SRL

Dual Sensor SRL

End Set EC1SR36W

End Set EC1DR36W

16' Run:8' (243.84cm) Master Module, 8' (243.84cm) Slave Module, standard Energos End Set, and Intermediate Cable Assembly.

16' Run:8' (243.84cm) Master Module, 8' (243.84cm) Slave Module, Single Sensor End Set, and Intermediate Cable Assembly.

16' Run:8' (243.84cm) Master Module, 8' (243.84cm) Slave Module, Single Sensor End Set, and Intermediate Cable Assembly.

Notes:

1.See page 1 of Specification Sheet or consult Application Guide for the definition of Serial Row Linking (SRL).

2.Consult the matching EG specification sheet for Luminaire related specifications (i.e. Housing materials, shielding, mounting dimensions, and photometry).

Standard End

SRL Standard

Set EG1EC36W

End Set EC1ER36W