Lighting Systems EC1-8

Page 3 of 3

 

 

Energos Control System 1-Light T8 per 4' (121.92cm) (Nominal) Lens

 

Ballast Ordering Information

 

 

Lamp Ordering Information

 

Design

Lamp Type

Ballast Factor

Start Type

THD %

Design

Lamp Type

Wattage

Rated Output

Color (K)

(Lumens)

 

 

 

 

 

 

 

 

 

D

T8

0.71

Program

<10

A

T8

28

2725

3000

E

T8

0.88

Program

<10

B

T8

28

2725

3500

H

Dim T8

1.00 / .05

Program

<10

C

T8

28

2725

4100

 

 

 

 

 

D

T8

30

2850

3000

 

 

 

 

 

E

T8

30

2850

3500

 

 

 

 

 

F

T8

30

2850

4100

 

 

 

 

 

G

T8

32

3000

3000

 

 

 

 

 

H

T8

32

3000

3500

 

 

 

 

 

I

T8

32

3000

4100

 

 

 

 

 

J

T8

32

3100

3000

 

 

 

 

 

K

T8

32

3100

3500

 

 

 

 

 

L

T8

32

3150

4100

Lamp and Ballast System Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lamp Type

 

Ballast

 

Ballast

 

Lamp Rated

 

Lamp

 

Lamp

 

IES Output

 

System

 

System

 

System

 

Start

 

 

 

 

 

 

 

 

 

 

 

Design

 

 

 

 

Rated

 

Color

 

 

Input

 

Efficacy

 

Lamp Life

 

(T8 or T5)

 

Factor (BF)

 

THD (%)

 

Wattage

 

 

 

(lumens)

 

 

 

 

Type

 

 

 

 

 

Output

 

(Kelvin)

 

 

Watts

 

(lum/watt)

 

(Hours)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DA

T8

 

0.71

 

<10

 

28

 

2725

 

3000

 

2199

 

20.0

 

96.74

 

24000

 

Program

DB

T8

 

0.71

 

<10

 

28

 

2725

 

3500

 

2199

 

20.0

 

96.74

 

24000

 

Program

DC

T8

 

0.71

 

<10

 

28

 

2725

 

4100

 

2199

 

20.0

 

96.74

 

24000

 

Program

DD

T8

 

0.71

 

<10

 

30

 

2850

 

3000

 

2299

 

21.5

 

94.12

 

24000

 

Program

DE

T8

 

0.71

 

<10

 

30

 

2850

 

3500

 

2299

 

21.5

 

94.12

 

24000

 

Program

DF

T8

 

0.71

 

<10

 

30

 

2850

 

4100

 

2299

 

21.5

 

94.12

 

24000

 

Program

DG

T8

 

0.71

 

<10

 

32

 

3000

 

3000

 

2420

 

23.0

 

92.61

 

24000

 

Program

DH

T8

 

0.71

 

<10

 

32

 

3000

 

3500

 

2420

 

23.0

 

92.61

 

24000

 

Program

DI

T8

 

0.71

 

<10

 

32

 

3000

 

4100

 

2420

 

23.0

 

92.61

 

24000

 

Program

DJ

T8

 

0.71

 

<10

 

32

 

3100

 

3000

 

2501

 

23.0

 

95.70

 

30000

 

Program

DK

T8

 

0.71

 

<10

 

32

 

3100

 

3500

 

2501

 

23.0

 

95.70

 

30000

 

Program

DL

T8

 

0.71

 

<10

 

32

 

3150

 

4100

 

2541

 

23.0

 

97.24

 

30000

 

Program

EA

T8

 

0.88

 

<10

 

28

 

2725

 

3000

 

2725

 

25.5

 

94.04

 

24000

 

Program

EB

T8

 

0.88

 

<10

 

28

 

2725

 

3500

 

2725

 

25.5

 

94.04

 

24000

 

Program

EC

T8

 

0.88

 

<10

 

28

 

2725

 

4100

 

2725

 

25.5

 

94.04

 

24000

 

Program

ED

T8

 

0.88

 

<10

 

30

 

2850

 

3000

 

2850

 

27.5

 

91.20

 

24000

 

Program

EE

T8

 

0.88

 

<10

 

30

 

2850

 

3500

 

2850

 

27.5

 

91.20

 

24000

 

Program

EF

T8

 

0.88

 

<10

 

30

 

2850

 

4100

 

2850

 

27.5

 

91.20

 

24000

 

Program

EG

T8

 

0.88

 

<10

 

32

 

3000

 

3000

 

3000

 

29.0

 

91.03

 

24000

 

Program

EH

T8

 

0.88

 

<10

 

32

 

3000

 

3500

 

3000

 

29.0

 

91.03

 

24000

 

Program

EI

T8

 

0.88

 

<10

 

32

 

3000

 

4100

 

3000

 

29.0

 

91.03

 

24000

 

Program

EJ

T8

 

0.88

 

<10

 

32

 

3100

 

3000

 

3100

 

29.0

 

94.07

 

24000

 

Program

EK

T8

 

0.88

 

<10

 

32

 

3100

 

3500

 

3100

 

29.0

 

94.07

 

24000

 

Program

EL

T8

 

0.88

 

<10

 

32

 

3150

 

4100

 

3150

 

29.0

 

95.59

 

24000

 

Program

HG

T8 DIM

 

1.0 / 0.5

 

<10

 

32

 

2850

 

3000

 

2850 / 143

 

34 / 8

 

83.80

 

NA

 

Program

HH

T8 DIM

 

1.0 / 0.5

 

<10

 

32

 

2850

 

3500

 

2850 / 143

 

34 / 8

 

83.80

 

NA

 

Program

HI

T8 DIM

 

1.0 / 0.5

 

<10

 

32

 

2850

 

4100

 

2850 / 143

 

34 / 8

 

83.80

 

NA

 

Program

*25°C Rating

All data is per 1 lamp on a two lamp system at 277 VAC. Data is based on Osram Sylvania specifications.

When ordering no lamps provided by Lightolier, use lamp code “Z”.

Do not alter lumen values or ballast factor light losses when completing calculations using Energos IES files. Files have already been adjusted. The lumen value for the lamp (within a Lighting Design program) will be the IES Ouput value shown on this table.

The lamp life table demonstrates the effects of shortened cycle-times with both program start and instant start ballasts. The graph shows that instant ballasts are susceptible to shortened lamp life if short cycle periods of less than 3 hours are used. For cycle periods of greater than 3 hours program start ballast are not required.

Lamp Life Table using program start and instant start ballasts.

Job Information

Type:

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2008 Philips Group • C0808

Page 3
Image 3
Lightolier EC1-8 specifications Lamp Ordering Information, Wattage

EC1-8 specifications

Lightolier EC1-8 is an innovative lighting solution that stands out for its advanced features and exceptional technology. This product is part of the Lightolier brand, known for delivering high-quality lighting fixtures that blend aesthetics and functionality. The EC1-8 is designed to meet the demands of various commercial and residential applications, providing both efficiency and elegance.

One of the main features of the EC1-8 is its energy-efficient LED technology. This offers significant benefits in terms of power consumption, making it an environmentally friendly choice. By utilizing LED lamps, the fixture not only reduces energy costs but also extends the lifespan of the lighting elements. This longevity results in decreased maintenance frequency and costs, making it an economical choice over time.

The EC1-8 boasts a sleek and modern design, allowing it to seamlessly integrate into any interior decor. Its minimalistic aesthetic is complemented by a range of finishes, enabling users to select options that best match their space. The fixture is suitable for various settings, including offices, retail spaces, and residential environments.

Another prominent characteristic of the EC1-8 is its versatility in lighting control. It is compatible with various dimming systems, providing users with the ability to adjust brightness levels to suit different activities and moods. This flexibility enhances the overall user experience and creates a more dynamic lighting environment.

The EC1-8 also features advanced optics technology, which ensures that light is distributed evenly across the space, minimizing glare and shadows. This makes it particularly effective for task-oriented environments where clear visibility is essential. The carefully engineered optics also contribute to the fixture's overall efficiency, maximizing light output while minimizing wasted energy.

Furthermore, the EC1-8 is engineered for easy installation and maintenance. The fixture is designed with user-friendly features that simplify both the setup process and ongoing upkeep. This user-oriented approach ensures that even those without extensive experience in lighting installation can achieve optimal results.

In conclusion, the Lightolier EC1-8 is a remarkable lighting solution that combines energy efficiency, aesthetic appeal, and advanced technological features. With its LED technology, versatile design, and excellent performance, it stands as an ideal choice for various applications, catering to the needs of both residential and commercial users. Embracing the EC1-8 not only enhances the visual appeal of a space but also supports sustainability and efficiency.