4

Chain Hanger

Occupancy Sensor

• For Chain Hanger, use 2 chains for 4ft or 8ft,

 

• Occupancy Sensor is supplied assembled to

 

 

or for individual or continuous row mounting.

End Cover and is secured to Housing with Screw

Housing is supported by inserting Hook into

as shown.

Slots in housing with ends of Hooks up

 

through next set of slots.

 

Slots

Housing

S Hook

Slots (8)

11/16” Dia. K.O.

Screw

SHook

Chain Hanger

 

End

Hook

Cover

Occupancy

Sensor

Housing is supported by inserting Hook into Slots in Housing with ends of Hooks up thru next set of slots.

Housing

End

Plate

End Plate

 

 

 

4-3/8”

 

 

 

(111mm)

 

4-3/8”

S Hook

7/8” Dia. K.O.

 

(111mm)

Slots (8)

(2 places)

7/8” Dia. K.O.

 

3-1/8”

(81mm)

11/16” Dia. K.O.

(2 Places)

3-1/8”

(81mm)

(2 Places)

39-3/8” (999mm)

48” (1220mm)

87-3/8” (2219mm)

41-3/4” (1059mm)

48” (1220mm)

89-3/4" (2279mm)

96" (2441mm)

5 Final Assembly (Louver)

Replace Side Reflectors–put Tabs into Slots.

Hang Louver Assembly on one Side Reflector.

Attach Safety Chain (both ends of fixture) to hole on the side of the louver.

Rotate free side of Louver Assembly upward until Louver Assembly rests evenly on both Side Reflectors.

Fixture End

Side

Reflector

Safety

Chain

Side

Safety

Reflector

Chain

Side

Reflector

Louver Blade

Final Assembly (Prismatic DR Acrylic Lens)

Replace Side Reflectors–put Tabs into Slots.

Hang Prismatic DR Acrylic Lens on one Slot Reflector.

Attach each Safety Cable “S” Hook to hole in Side Reflector.

Rotate free side of Prismatic DR Acrylic Lens upward until lens rests evenly on both Side Reflectors.

Fixture

Side

End

Reflector

 

 

Side

 

 

Reflector

Safety

 

 

Cable

 

 

Prismatic

"S"

 

Hook

 

DR Acrylic

 

 

 

Lens

Safety

 

 

Cable

Side Reflector

 

 

Page 2
Image 2
Lightolier Eye-QLB installation instructions Final Assembly Louver, Final Assembly Prismatic DR Acrylic Lens