Lightolier EYS Series Page 2 of, Photometry, Ordering Information, Options & Accessories, Type

Models: EYS Series

1 2
Download 2 pages 50.31 Kb
Page 2
Image 2
Page 2 of 2
SECTION 5/Folio K40-10

EYE-Q INDIRECT/DIRECT OR DIRECT EYS SERIES 25° LOUVER

Page 2 of 2

PHOTOMETRY

EYS825FX232120O4

SUSPENDED/SURFACE FLUORESCENT LUMINAIRE, SOLID SIDE REFLECTORS, 25° LOUVER

48” LENGTH, 2 LAMP T8; 96” LENGTH, 2 LAMP T8 IN TANDEM

MODEL NO. EYS825FX232120O4

coefficients of utilization — zonal cavity method

 

RF

 

20

 

 

20

 

 

20

 

 

RC

 

80

 

 

50

 

 

30

 

 

RW

70

50

30

50

30

10

50

30

10

 

1

85

82

78

62

60

58

50

48

47

ratio

2

78

72

67

54

51

49

44

42

40

3

71

63

57

48

44

41

39

36

34

cavity

4

65

56

49

43

39

35

35

32

29

5

60

50

43

39

34

30

32

28

26

room

6

55

45

38

35

30

27

29

25

22

7

51

41

34

32

27

23

26

22

20

 

8

47

37

30

29

24

21

24

20

18

 

9

44

34

27

26

22

19

22

18

16

 

10

41

31

24

24

20

17

20

17

14

Louver Shielding: 33° Crosswise

25° Lengthwise

ORDERING INFORMATION

Explanation of Catalog Number. Example: EYS825FX232120O4

EY

EYE-Q:

Suspended/

Surface

Fluorescent

Luminaire

S

SIDE:

S=Solid

25

FIXTURE LENGTH:

4=48”

8=96”

SHIELDING:

25° Louver

Cut-off

F

 

 

 

 

 

2

 

32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FINISH:

 

 

LAMP

 

 

 

VOLTAGE:

 

 

 

 

 

 

 

OPTIONS:

F= Flat White

 

 

QUANTITY

 

 

 

120 or 277

 

 

 

 

 

Add appropriate

(standard)

 

 

(Nominal 48”)

 

 

 

 

 

 

 

 

 

 

 

suffix to catalog

 

 

 

 

 

 

 

2-Lamps

 

 

 

 

 

 

 

 

 

 

 

 

no., ie: (GLR)

 

 

 

 

 

 

 

(Nominal 96”)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-Lamps in tandem

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MOUNTING:

LAMP/TYPE:

 

 

 

 

BALLAST TYPE:

 

 

 

 

X=No Reflector

(4 lamps)

32 Watt T8

 

 

SO=Electronic (T8)

 

 

 

 

 

(Uplight/Downlight)

 

 

 

 

 

 

 

(2 lamps)

 

 

 

 

S=Top Reflector

 

 

 

 

 

 

 

 

 

O4=1-4 Lamp Elect. (T8)

 

 

 

 

 

(Downlight Only)

 

 

 

 

 

 

 

 

 

 

 

(8' only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPTIONS & ACCESSORIES

STEM AND CANOPY SETS: Suspend fixture 6”, 12”, 18” or 24” from surface.

Catalog Number: ASC6 CSP (6”), ASC12 CSP (12”), ASC18 CSP (18”), ASC24 CSP (24”).

FUSING: Internal fast-blow fusing. Suffix: GLR. Internal slow-blow fusing. Suffix: GMF.

EMERGENCY PACK: Factory-installed emergency power battery pack with

charger and inverter, LP400 or equal, 120 or 277 volt. Suffix: LP400.

CABLE HANGERS: Adjustable 6"-60"

Single Cable and Canopy: Catalog Number WC60.

Single Cable, Straight Cord and Canopy: Catalog Number WCC60.

Single Cable, Coil Cord and Canopy: Catalog Number WCCC60.

SPECIFICATIONS

MATERIALS: Housing is die-formed 20 gauge cold rolled steel full length channel for thru wiring.

Fixture Ends: 18 gauge cold rolled steel with 1-3/4” x 2” flush K.O. for thru wiring.

SPECIFICATIONS (continued)

Louver: 22 gauge cold rolled steel.

Side Reflectors: Solid 22 gauge cold rolled steel.

FINISH: Post painted white acrylic baked enamel.

ELECTRICAL: Electronic instant start (<20 THD) thermally protected class “P” HPF non PCB, UL Listed, CSA Certified ballast for T8 lamps. If K.O. is within 3” of ballast, use wire suitable for 90°.

LABELS: I.B.E.W. UL and ULc Listed.

Job Information

 

Type:

Lightolier a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902

Page 2
Image 2