Lightolier FBP90 warranty One Lamp Operation 600 Lumens, Page 1 of, Model #, Max. Lumens, Options

Models: FBP90

1 1
Download 1 pages 8.78 Kb
Page 1
Image 1
FBP Series Fluorescent Emergency Ballast  FBP90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FBP Series Fluorescent Emergency Ballast  FBP90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 1 of 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

One Lamp Operation 600 Lumens

The FBP Series quickly converts standard fluorescent luminaires into emergency luminaires.

9.4”

(23.9 cm)

 

2.4”

1.5”

Nickel Cadmium Battery

(3.8 cm)

(6.1 cm)

 

Complete Fixture consists of ballast unit. Select options and accessories below.

Model #

Max. Lumens

Lamp Operation

 

FBP90

600

One

 

 

 

 

Features

1.Lamp Operation: Operates the following lamp types: T8 linear fluorescent, T12 linear fluorescent, T9 circline, T12 U-bent, T5 long compact fluorescent. See Lamp Operation and Performance table for specific lamp performance and operation.

2.Illumination: Provides 90 minutes of emergency illumination, and produces 500-600 lumens initial emergency light output. Can be used with most 17w to 40w (2’ - 4’) T8, T10 or T12 fluorescent lamps without integral starters including U-shaped, HO, VHO, circline, energy saving, and 4 pin compacts. It is also compatible with most 1, 2, 3 and 4-lamp electronic, standard, energy saving and dimming AC ballasts.

3.Housing: Constructed of 20 gauge steel with a white high temperature pow- der coat paint finish. Slim housing allows for wireway channel mounting on most recessed luminaires.

4.Electronics: 120/277 VAC dual voltage input with surge-protected, solid- state circuitry. Charging system is complete with AC indicator lamp and test switch.

5.Battery: Maintenance free, sealed nickel cadmium battery has an estimated service life of 10 years, and an operating temperature range of 32°F (0°C) to 131°F (55°C).

6.Input Power Requirements: 4 watts max.

7.Warranty: Electronics: 1 year; Battery: 1 year.

Code Compliance

UL 924 listed.

Options

EX = Special Input Transformer for 220 VAC/50 Hz, 240 VAC/50Hz. Contact factory for other input voltages and frequencies.

DL = UL Damp Location Listing

Lamp Operation and Performance

 

 

 

 

 

 

 

Non-Emer.

 

Emer. Op.

 

 

 

 

 

 

 

 

Max.

 

Max.

Emer

 

Lamp

 

 

 

Base

 

Lumen

 

Lumen

Lamp

 

Type

 

Watt.

 

Type

 

Output

 

Output

Operation

 

 

 

 

 

 

 

 

 

 

 

F20T12

 

20

 

G13/Med Bi-Pin

 

1275

 

500 - 600

One

F30T12

 

30

 

G13/Med Bi-Pin

 

2350

 

500 - 600

One

F40T12

 

40

 

G13/Med Bi-Pin

 

2650

 

500 - 600

One

F40T12/U

 

40

 

G13/Med Bi-Pin

 

3100

 

500 - 600

One

F48T10

 

110

 

R17D/Recessed

 

6200

 

500 - 600

One

 

F17T8

 

17

 

G13/Med Bi-Pin

 

1350

 

500 - 600

One

 

F25T8

 

25

 

G13/Med Bi-Pin

 

2150

 

500 - 600

One

 

F32T8

 

32

 

G13/Med Bi-Pin

 

2950

 

500 - 600

One

F32T8/U

 

32

 

G13/Med Bi-Pin

 

2700

 

500 - 600

One

F40T8

 

40

 

G13/Med Bi-Pin

 

3725

 

500 - 600

One

 

FC6T9

 

20

 

G10Q/4 Pin

 

800

 

500 - 600

One

 

FC8T9

 

22

 

G10Q/4 Pin

 

1100

 

500 - 600

One

FC12T9

 

32

 

G10Q/4 Pin

 

1950

 

500 - 600

One

FC16T9

 

40

 

G10Q/4 Pin

 

2700

 

500 - 600

One

F39/36BX

 

39

 

2G11/4 Pin

 

2850

 

500 - 600

One

F40/30BX

 

40

 

2G11/4 Pin

 

3150

 

350 - 450

One

 

 

 

 

Notes:

1.Maximum non-emergency lumen output can vary based on lamp manufacturer, ambient operating temperature, and ballast manufacturer.

2.Maximum emergency lumen output is based on total output of one or two lamps, and can vary based on lamp manufacturer and ambient operating temperature.

3.Maximum emergency lumen output is supported for a full 90 minutes of operation.

4.Consult factory for compatibility, operation and performance of lamp types not listed.

Accessories

CCAPS = Wire bundle cover for mounting external to luminaire

RTS = Single gang aluminum faceplate pre-drilled to accommodate remote installa- tion of test switch and pilot light

Job Information Type:

Job Name:

Cat. No.:

Lamp(s):

Notes:

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2008 Philips Group • C0308

Lightolier is a Philips group brand

Page 1
Image 1
Lightolier warranty One Lamp Operation 600 Lumens, FBP Series Fluorescent Emergency BallastFBP90, Page 1 of, Model #