Section 2/Folio G40-16 REV. A

 

STACKLYTE STA 1'x4' 2 LAMP

Page 2 of 2

1'x4' RECESSED FLUORESCENT, 3" DEEP, 8 OR 12 CELL PARABOLIC LOUVER

 

STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR NORMAL VDT USE

PHOTOMETRY

MODEL NO. STA1G8LR232120SO

 

LER = FL - 55.0

IW - 61.9

BF - 0.88

 

 

 

 

 

Comparative yearly lighting energy cost per 1000 lumens = $4.36

 

 

 

 

coefficients of utilization — zonal cavity method

 

 

 

 

 

 

 

 

RF

 

 

20

 

 

20

 

 

20

 

 

 

RC

 

 

80

 

 

50

 

 

30

 

 

 

RW

 

70

50

30

50

30

10

50

30

10

 

 

1

 

77

74

72

70

68

67

67

66

65

 

ratio

2

 

71

67

64

64

61

59

61

59

57

 

3

 

66

61

56

58

54

52

56

53

51

 

cavity

4

 

62

55

50

53

49

46

51

48

45

 

5

 

57

50

45

48

44

41

47

43

40

 

 

 

 

room

6

 

53

46

40

44

40

36

43

39

36

 

7

 

50

42

37

40

36

33

39

35

32

 

 

8

 

47

38

33

37

33

29

36

32

29

 

 

9

 

44

35

30

34

30

27

34

30

27

 

 

10

 

41

33

28

32

27

24

31

27

24

VERTICAL FOOTCANDLES ON BOOK SHELVES

Ceiling

 

 

 

1'

 

2'

 

3'

 

4'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.00

84.9

85.1

85.2

85.0

84.8

85.0

85.1

85.1

84.9

2.00

64.5

63.9

64.1

64.2

64.3

64.2

64.1

63.8

64.5

3.00

50.1

50.2

50.1

50.1

50.2

50.1

50.1

50.2

50.1

4.00

41.3

41.2

41.3

41.3

41.3

41.3

41.3

41.2

41.2

5.00

36.8

36.7

36.8

36.7

36.7

36.7

36.8

36.7

36.8

6.00

32.1

32.1

32.1

32.1

32.1

32.1

32.1

32.1

32.1

7.00

28.9

28.9

28.9

28.9

28.9

28.9

28.9

28.9

28.9

8.00

27.5

27.5

27.5

27.5

27.4

27.5

27.5

27.5

27.5

9.00

25.9

25.8

25.8

25.8

25.8

25.8

25.8

25.8

25.9

10.00

23.9

23.8

23.8

23.8

23.8

23.8

23.8

23.8

23.8

11.00

21.1

21.1

21.1

21.1

21.1

21.1

21.1

21.1

21.1

12.00

17.5

17.5

17.5

17.5

17.5

17.5

17.5

17.5

17.5

 

Floor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0'

 

1'

 

2'

 

3'

 

4'

 

 

 

 

 

 

 

 

Book shelf aisle width, 36"

 

 

 

 

 

ORDERING INFORMATION

To meet NYC Code requirements prefix catalog number

Explanation of Catalog Number. Example: STA1G8LR232120SOGLR

with (N).

ST

1

R

2

 

 

 

 

 

 

 

 

 

 

 

BLANK = Standard

 

 

 

BODY STYLE:

 

 

 

CEILING TYPE:

N = NYC Code

 

 

 

A=Air Handling

 

 

G= Grid (lay-in T bar)

 

 

 

 

 

S=Static

 

 

F=Flanged (overlap)

 

 

 

 

 

 

 

 

 

Z spline and

 

 

 

 

 

 

 

 

 

 

STACKLYTE:

 

FIXTURE

 

 

 

plaster frame

 

3" Deep

 

WIDTH

 

 

 

T=Slot grid or

 

Precision

 

 

 

 

two-directional

Contoured

concealed T

Pre-

(see options)

anodized

 

Aluminum

 

Louver

 

NUMBER OF

CELLS: 8=1 row of

8cells

12=1 row of

12cells

LOUVER

FINISH: L=Low

Iridescence Semi-specular (standard)

P=Low iridescence specular

 

 

 

 

 

 

 

 

 

 

 

VOLTAGE:

 

 

 

OPTIONS:

 

 

 

 

LAMP

 

 

 

 

 

 

 

 

 

 

 

QUANTITY

 

 

 

 

 

120 or 277

 

Add appropriate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

suffix to catalog

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

no, ie: (GLR)

 

REFLECTOR:

 

 

 

 

LAMP/

 

BALLAST TYPE:

 

R=Specular

 

 

FIXTURE LENGTH:

1 Lamp Mag. T12

LE

 

 

 

 

95%

 

 

 

 

 

 

32=T8

 

 

 

 

 

 

 

 

 

 

 

<20THD

<10THD

 

Reflective

 

 

34=T12

 

 

 

 

 

 

 

1 Lamp Elec. T8

SO*

HI*

 

 

 

 

 

 

 

 

(Nominal 48")

 

 

 

 

 

 

 

 

 

 

 

 

 

LOL Dimming

PS

 

 

Other dimming options.

Consult factory.

 

*Instant Start Standard

 

OPTIONS & ACCESSORIES

ACCESS PLATE: Top Wiring access plate is shipped with fixture as standard. When access plates are required in advance for wiring convenience, specify sepa- rately. Order Catalog Number: ACP CSP.

ELECTRICAL WIRING OPTIONS: Consult factory.

FUSING: Internal fast-blow fusing. SUFFIX: GLR. Internal slow-blow fusing. SUFFIX: GMF.

RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture

standard. SUFFIX: RF.

SPLAY TRIM: For T ceiling type only. SUFFIX: CTZ14 .

PLASTER FRAMES: F type fixtures do not include plaster frames. For individual or continuous mounting, specify PF14 universal frame per fixture.

AIR CLOSURE STRIPS: SUFFIX ACS4 (factory installed).

DRYWALL KIT: Order Catalog Number: FK91X4. Request Folio OA30-10.

CHICAGO PLENUM: SUFFIX: CP.

SPECIFICATIONS

PERFORMANCE: Luminaire distribution is to be a minimum of 97.5% in the 0°- 60° zone. In an installation of 2 lamp 32W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .80 with a spacing to mounting ratio of 1.6 perpendicular to the lamps. To meet IES RP1 recommended (basic) requirements for VDT areas the VCP (visual comfort probabili- ty) shall not be less than 90 either crosswise or lengthwise, and the maximum

SPECIFICATIONS (continued)

average brightness at 65°, 75° and 85° shall not exceed 617, 191 and 162 can- delas per square meter respectively in the 0°, 45° and 90° horizontal planes. AIR HANDLING: (STA only) side air passages for air supply or air return. Optional side closure strips. Air return is also provided through the lamp com- partment through fixture body ends.

MATERIALS: Chassis parts are die-formed embossed cold rolled steel. Housing is embossed for rigidity with all edges turned-in for safe handling. LOUVER: Pre-anodized aluminum (Coilzak® or equal).

FINISH: Louver—semi-specular low iridescence pre-anodized reflector sheet. Reflector—95% reflective specular. Phosphate undercoating.

Chassis exterior—black baked polyester enamel.

ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

LABELS: I.B.E.W./UL and C-UL.

Job Information

 

Type:

Lightolier a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902

Page 2
Image 2
Lightolier Fluorescent Lighting Page 2 of, Photometry, Ordering Information, Options & Accessories, Specifications, Type