FRX Series FRS2GFW2FT

Page 2 of 2

Model No. FRS2GFW2FTUNVIB (25 watt lamp)

Architectural Recessed Fluorescent 2' x 2' with Frost White Acrylic Lens, 2 Lamp TT5

Model No. FRS2GFW2FTUNVIB (40 watt lamp)

LER = FP - 59.1 IW - 59.9 BF - 0.92 Comparative yearly lighting energy cost per

1000 lumens = $4.06

Report Number: G2008273

Catalog Number: FRS2GFW2FTUNVIB

Lamps: (2) PL-L40/835/XEW/4P/RS/IS 25W

Luminaire: FRX Architectural Recessed 2' x 2' fixture with acrylic lens.

Ballast: ICN-2TTP40-SC

Report is based on 2600 Lumens per lamp. Efficiency: 74.0%

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.2

 

 

1.2

Shielding Angles:

 

 

90

 

 

90

Plane:

 

 

 

 

0-Deg

 

90-Deg

Luminous Length:

 

21.600

 

21.600

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.200

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

01

81

77

74

72

70

68

69

67

66

02

73

67

62

63

59

56

61

57

55

03

67

59

53

56

51

47

54

50

46

04

61

52

46

49

44

40

48

43

39

05

56

47

40

44

39

35

43

38

34

06

52

42

36

40

35

30

38

34

30

07

48

38

32

36

31

27

39

30

27

08

45

35

29

33

28

24

35

28

24

09

42

32

26

31

25

22

32

25

22

10

39

30

24

28

23

20

28

23

20

CANDELA DISTRIBUTION

 

0.0

45.0

90.0

FLUX

0

1421

1421

1421

 

5

1407

1406

1407

134

15

1341

1339

1339

378

25

1241

1227

1227

566

35

1084

1078

1074

675

45

903

897

888

692

55

697

693

676

616

65

469

470

444

458

75

236

244

212

251

85

68

70

48

79

90

52

52

31

 

 

 

 

 

 

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

00-030

1078

20.7

28.0

00-040

1753

33.7

45.5

00-060

3061

58.9

79.5

00-090

3849

74.0

100.0

90-180

0000

0.0

000.0

00-180

3849

74.0

100.0

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG. 45-DEG. 90-DEG.

45

4104.

4077.

4036.

55

3852.

3830.

3736.

65

3440.

3447.

3256.

75

2693.

2784.

2419.

85

1876.

1931.

1324.

LER = FP - 55.5 IW - 69.5 BF - 0.92 Comparative yearly lighting energy cost per

1000 lumens = $4.26

Report Number: G2008272

Catalog Number: FRS2GFW2FTUNVIB

Lamps: (2) PL-L40/835/RS/IS

Luminaire: FRX Architectural Recessed 2' x 2' fixture with acrylic lens.

Ballast: ICN-2TTP40-SC

Report is based on 3300 Lumens per lamp. Efficiency: 63.5%

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.2

 

 

1.2

Shielding Angles:

 

 

90

 

 

90

Plane:

 

 

 

 

0-Deg

 

90-Deg

Luminous Length:

 

21.600

 

21.600

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.200

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

01

69

66

63

62

60

58

59

58

56

02

63

57

53

54

51

48

52

49

47

03

57

50

45

48

43

40

46

42

39

04

52

45

39

42

38

34

41

37

34

05

48

40

34

38

33

29

37

32

29

06

44

36

30

34

29

26

33

29

26

07

41

33

37

31

26

23

30

26

23

08

38

30

24

28

24

20

28

23

20

09

36

26

22

26

22

18

26

21

18

10

34

25

20

24

20

17

24

20

17

CANDELA DISTRIBUTION

 

0.0

45.0

90.0

FLUX

0

1512

1512

1512

 

5

1500

1499

1500

143

15

1434

1432

1433

405

25

1322

1318

1318

608

35

1169

1162

1159

728

45

980

971

963

750

55

764

756

737

673

65

523

519

490

507

75

275

279

242

287

85

83

85

62

93

90

55

56

33

 

 

 

 

 

 

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

00-030

1155

17.5

27.6

00-040

1883

28.5

44.9

00-060

3306

50.1

78.8

00-090

4194

63.5

100.0

90-180

0000

0.0

000.0

00-180

4194

63.5

100.0

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG. 45-DEG. 90-DEG.

45

4454.

4413.

4377.

55

4223.

4178.

4073.

65

3836.

3806.

3594.

75

3138.

3184.

2762.

85

2290.

2345.

1711.

Ordering Information

Explanation of Catalog Number. Example: FRS2GFW2FTUNVIB

S

2

G

F

W

2

FT

 

 

 

 

 

 

 

 

 

Reflector:

Lamp

 

 

 

 

 

 

 

 

 

 

 

FRX

Body Style:

Fixture

Ceiling

 

Type:

Lens:

 

 

 

 

 

 

 

 

 

 

 

 

 

Lamp:

Voltage:

 

 

 

Options:

Architectural

S = Static

Width

G = Standard

F= Frost White

White

Quantity

 

(By Others)

120, 277 or

 

 

Add appropriate

Recessed

 

 

Grid

Acrylic Lens

 

2=2 Lamp

FT = Twin Tube T5

UNV=120-277

 

 

suffix to catalog

Fluorescent

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

no., ie: (A)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ballast Type:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<20THD <10THD

FR

 

Standard FRX

 

 

 

 

 

 

 

 

 

 

 

 

2 Lamp Elec. TT5

 

 

SB*

IB**

 

 

 

 

 

 

 

 

 

 

 

 

 

(25 or 40 Watt)

 

 

PR†

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 Lamp Elec. TT5

 

 

FY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For NYC Code – I.B.E.W. Manufactured

 

 

 

 

 

 

 

 

 

 

 

(40 Watt)

 

 

BE*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 Lamp Elec. TT5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FN

 

For NYC Code – Local 3 Manufactured

 

 

 

 

 

 

 

 

 

 

 

(50 Watt)

 

 

BF*

 

 

 

 

 

 

 

 

 

 

 

 

2 Lamp Elec. TT5

 

 

 

5½" Deep Body

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(55 Watt)

 

 

PB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOL Dimming TT5

 

 

 

Options/Accessories

Fusing: Internal fast blow fusing: SUFFIX: A.

Internal slow blow fusing: SUFFIX: C.

Drywall Kit: Order Catalog Number: FK92X2.

Electrical Wiring Options: Consult factory.

For motion or light sensor: See Folio OA20-10 and OA20-30.

Specifications

Performance: In an installation of 2 lamp 25W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .77. To reduce glare the average brightness at 65° shall not exceed 3447 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 72.0%.

Lamp Shield: Frost white DR acrylic lens.

Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing is ribbed for rigidity with side rails hemmed over and housing ends turned-in for safe handling.

Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Rust preventative undercoating.

*Instant Start Standard.

Other dimming options. Consult factory.

NOTE:

For TT5 40W UNV, you must use PR Ballast Code. †Program Rapid Start

Specifications (continuned)

Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed.

This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org

Job Information Type:

For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

www.lightolier.com © 2008 a Philips Group

Section 5/Folio MA10-12

Lightolier is a Philips group brand

Page 2
Image 2
Lightolier FRS2GFW2FT dimensions Ordering Information, Options/Accessories, Specifications continuned

FRS2GFW2FT specifications

The Lightolier FRS2GFW2FT is a standout fixture in the world of commercial and architectural lighting, designed to combine efficiency and aesthetics. As a part of the FRS series, this luminaire offers a sleek, modern profile that seamlessly integrates into various spaces. With dimensions of 2 feet in length, it provides a versatile solution suitable for a range of applications, from office environments to retail settings.

One of the key features of the Lightolier FRS2GFW2FT is its ability to deliver high-quality illumination while maintaining energy efficiency. The fixture utilizes advanced LED technology, which not only enhances brightness but significantly reduces energy consumption compared to traditional fluorescent or incandescent options. By opting for this LED fixture, users can expect up to 80 percent energy savings, leading to lower utility bills and a reduced carbon footprint.

The FRS2GFW2FT is designed with a clean, minimalist aesthetic that complements modern interiors. Its low-profile design allows it to blend seamlessly with ceilings, while the frosted lens ensures that light is diffused evenly across the space, eliminating harsh shadows. This thoughtful illumination is ideal for creating comfortable work or shopping environments.

Additionally, the fixture features versatile mounting options, including grid, surface, and suspension, providing flexibility for designers and installers. It is also compatible with various dimming technologies, making it easy to adjust light levels to suit different activities and preferences.

Durability is another hallmark of the Lightolier FRS2GFW2FT. Constructed from high-quality materials, it is built to withstand the rigors of daily use. The fixture boasts a long lifespan, rated at over 50,000 hours, which means reduced maintenance costs and less frequent replacements.

Moreover, the FRS2GFW2FT is designed with sustainability in mind. It is free of harmful substances, contributing to a healthier indoor environment. The fixture also complies with various industry standards and certifications, ensuring it meets the highest performance and safety benchmarks.

In conclusion, the Lightolier FRS2GFW2FT is a remarkable lighting solution that combines cutting-edge technology with elegant design. Its energy efficiency, aesthetic appeal, and durability make it an excellent choice for those looking to enhance their spaces with effective and stylish lighting.