Lightolier manual Page of, Job Informationv, Type, Vetro Architectural DecorativeFS01, Pendant

Models: FS01

1 2
Download 2 pages 43.13 Kb
Page 2
Image 2
Vetro Architectural Decorative  FS01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vetro Architectural Decorative  FS01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page of 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pendant

Catalog No. FS01, 13W 4-Pin Twin Tube, 800 Lumens.

0

 

4

 

 

60°

27

 

4

 

54

30°

 

 

Report No. 3108FR

CANDLEPOWER SUMMARY

 

ZONAL LUMEN SUMMARY

 

ZONAL LUMENS AND PERCENTAGES

 

 

 

 

 

COEFFICIENTS OF UTILIZATION

 

 

 

 

Ceiling

 

80%

 

70%

50%

30%

 

Angle Mean CP

Angle Mean CP

 

Zone

Lumens

Zone

Lumens

%Lamp

%Fixt

 

 

 

 

Wall

 

70

50

30

10

50

10

50

10

50

10

0

0

39

90

54

0-10

4.1

 

0-30

32.14

4

5.8

 

 

 

 

RCR

 

Zonal Cavity Method - Effective Floor Reflectance = 20%

5

42

95

54

10-20

11.89

 

0-40

54.24

6.8

9.8

 

 

10

45

100

54

20-30

16.15

 

0-60

125.68

15.7

22.8

 

 

0

74

74

74

74

69

69

58

58

49

49

36

 

 

 

1

64

60

56

52

55

48

46

40

37

33

23

15

43

105

53

30-40

22.11

 

0-90

289.44

36.2

52.4

 

 

 

 

 

2

57

50

44

40

46

37

38

31

31

25

17

20

38

110

51

40-50

31.03

 

90-120

163.26

20.4

29.6

 

Ratio

 

 

3

51

43

37

32

39

29

33

24

26

20

13

25

34

115

49

50-60

40.41

 

90-130

202.8

25.4

36.7

 

30

34

120

47

60-70

49.15

 

90-150

249.85

31.2

36.7

 

Cavity

4

46

37

31

26

34

24

28

20

23

16

10

 

 

5

42

33

26

22

30

20

25

17

20

14

8

35

35

125

44

70-80

55.68

 

90-180

262.55

32.8

47.6

 

40

37

130

41

80-90

58.92

 

0-180

551.99

69

100

 

Room

6

39

29

23

18

27

17

22

14

18

12

7

 

 

7

36

26

20

16

24

15

20

12

16

10

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45

40

135

37

90-100

58.92

 

**

Efficiency = 69% **

 

 

 

8

33

24

18

14

22

13

18

11

15

9

5

50

43

140

33

100-110

55.68

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

31

22

16

12

20

11

17

9

14

8

4

55

45

145

29

110-120

48.66

 

 

 

 

 

 

 

 

 

 

 

 

 

10

29

20

14

11

18

10

15

8

13

7

4

60

47

150

25

120-130

39.53

 

 

 

 

 

 

 

 

 

 

 

 

Determined In Accordance With Current IES Published Procedures

65

50

155

20

130-140

28.74

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Luminaire Input Watts = 16.0

 

 

 

70

51

160

15

140-150

18.32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75

53

165

10

150-160

9.51

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

54

170

5

160-170

2.91

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

85

54

175

2

170-180

.29

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90

54

180

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Catalog No. FS01Q, 13W 4-Pin Quad Tube, 900 Lumens.

COEFFICIENTS OF UTILIZATION

0

14

27

41

54

60°

30°

Report No. 3105FR

CANDLEPOWER SUMMARY

 

ZONAL LUMEN SUMMARY

 

ZONAL LUMENS AND PERCENTAGES

 

Ceiling

 

80%

 

70%

50%

30%

 

Angle Mean CP

Angle Mean CP

 

Zone

Lumens

Zone

Lumens

%Lamp

%Fixt

 

Wall

 

70

50

30

10

50

10

50

10

50

10

0

0

54

90

49

 

 

0-10

4.96

 

0-30

28.52

3.2

5.8

 

RCR

 

Zonal Cavity Method - Effective Floor Reflectance = 20%

5

54

95

49

10-20

10.5

 

0-40

47.41

5.3

9.6

 

 

0

59

59

59

59

55

55

46

46

39

39

28

10

48

100

48

20-30

13.06

 

0-60

110.28

12.3

22.4

 

 

1

51

47

44

41

43

38

36

32

30

26

18

15

43

105

47

30-40

18.89

 

0-90

256.23

28.5

52

 

Ratio

2

45

40

35

31

36

29

30

24

24

20

13

20

37

110

46

40-50

27.06

 

90-120

147.51

16.4

29.9

 

3

41

34

29

25

31

23

26

19

21

16

10

 

 

 

25

28

115

45

50-60

35.81

 

90-130

183.11

20.3

37.1

 

Cavity

4

37

30

24

20

27

19

22

16

18

13

8

30

28

120

42

60-70

43.7

 

90-150

225.8

25.1

37.1

 

5

34

26

21

17

24

16

20

13

16

11

6

35

30

125

40

70-80

49.73

 

90-180

236.85

26.3

48

 

Room

6

31

23

18

15

21

13

18

11

14

9

5

40

32

130

37

80-90

52.51

 

0-180

493.07

54.8

100

 

7

28

21

16

13

19

12

16

10

13

8

5

45

35

135

34

90

-100

53.33

 

** Efficiency = 54.8% **

 

 

 

8

26

19

14

11

17

10

14

9

12

7

4

50

37

140

30

100-110

49.99

 

 

 

 

 

 

 

9

25

17

13

10

16

9

13

8

11

6

4

55

40

145

26

110-120

44.19

 

 

 

 

 

10

23

16

11

9

14

8

12

7

10

5

3

60

42

150

22

120

-130

35.6

 

 

 

 

 

 

Determined In Accordance With Current IES Published Procedures

65

44

155

18

130-140

26.11

 

 

 

 

 

 

 

 

 

 

Luminaire Input Watts = 14.0

 

 

 

70

46

160

13

140

-150

16.58

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75

47

165

8

150

-160

8.29

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

48

170

4

160-170

2.51

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

85

48

175

2

170

-180

.25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90

49

180

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Catalog No. IS01, 50W T-4, 950 Lumens.

COEFFICIENTS OF UTILIZATION

0

 

1

 

40

 

 

60°

79

 

119

 

158

30°

 

Report No. 3101FR

 

CANDLEPOWER SUMMARY

 

ZONAL LUMEN SUMMARY

 

ZONAL LUMENS AND PERCENTAGES

 

Ceiling

 

80%

 

70%

50%

30%

 

Angle Mean CP

Angle Mean CP

 

Zone

Lumens

Zone

Lumens

%Lamp

%Fixt

 

Wall

 

70

50

30

10

50

10

50

10

50

10

0

0

158

90

33

 

 

0-10

8.06

 

0-30

23.21

2.4

6.8

 

RCR

 

Zonal Cavity Method - Effective Floor Reflectance = 20%

5

104

95

34

10-20

6.98

 

0-40

36.04

3.8

10.5

 

 

0

39

39

39

39

36

36

31

31

26

26

19

10

43

100

33

20-30

8.18

 

0-60

79.48

8.4

23.1

 

 

1

34

31

29

27

29

25

24

21

20

18

12

15

23

105

33

30-40

12.83

 

0-90

180.42

19

52.5

 

Ratio

2

30

26

23

21

24

19

20

16

16

13

9

20

18

110

32

40-50

18.63

 

90-120

101.76

10.7

29.6

 

3

27

23

19

17

21

15

17

13

14

11

7

 

 

 

25

17

115

31

50-60

24.81

 

90-130

126.02

13.3

36.7

 

Cavity

4

25

20

16

14

18

13

15

11

12

9

5

30

19

120

29

60-70

30.42

 

90-150

155.48

16.4

36.7

 

5

22

18

14

12

16

11

13

9

11

7

5

 

 

 

35

20

125

27

70-80

34.52

 

90-180

163.04

17.2

47.5

 

Room

6

21

16

12

10

14

9

12

8

10

6

4

40

22

130

25

80-90

36.01

 

0-180

343.46

36.2

100

 

7

19

14

11

9

13

8

11

7

9

6

3

45

24

135

23

90

-100

36.82

 

** Efficiency = 36.2% **

 

 

 

8

18

13

10

8

12

7

10

6

8

5

3

50

26

140

21

100-110

34.52

 

 

 

 

 

 

 

9

16

12

9

7

11

6

9

5

7

4

3

55

28

145

18

110-120

30.42

 

 

 

 

 

10

15

11

8

6

10

6

8

5

7

4

2

60

29

150

16

120

-130

24.26

 

 

 

 

 

 

Determined In Accordance With Current IES Published Procedures

65

31

155

13

130-140

17.85

 

 

 

 

 

 

 

 

 

 

Luminaire Input Watts = 50.0

 

 

 

70

32

160

9

140

-150

11.61

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75

33

165

5

150

-160

5.93

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

33

170

1

160-170

1.53

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

85

33

175

1

170

-180

.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90

33

180

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Job Informationv

Type:

 

 

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2008 Philips Group • 0308

Lightolier is a Philips group brand

Page 2
Image 2
Lightolier Page of, Job Informationv, Type, Vetro Architectural DecorativeFS01, Pendant, Coefficients Of Utilization