| Tangent™ Track Lighting System FXESR |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
Page 2 of 2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 120V GU10 Low Profile Ring |
AIMING ANGLE:
L Beam length | D | Distance |
W Beam Width | A | Aiming Angle |
C Distance to center beam | FC Footcandles |
L and W are the outer points where the candle power drops to 50% of the maximum. FC are the initial foot- candles at the center of the beam.
Lamp data shown is typical. Consult lamp manufacturers for availability and performance. CBCP= Center Beam Candle Power.
LAMP | Beam Spread | CBCP | Rated |
| (To 50% CBCP) | Life (Hrs.) | |
|
| ||
|
|
|
|
35W Philips |
| 480 | 3000 |
|
|
| |
GU10 | 25˚ |
|
|
|
| 0° |
|
|
D | C | FC | L | W |
5 | 0.0 | 19 | 2.2 | 2.2 |
6 | 0.0 | 13 | 2.7 | 2.7 |
7 | 0.0 | 10 | 3.1 | 3.1 |
8 | 0.0 | 8 | 3.5 | 3.5 |
30° Horizontal
D | C | FC | L | W |
5 | 2.9 | 12 | 3.0 | 2.6 |
6 | 3.5 | 9 | 3.6 | 3.1 |
7 | 4.0 | 6 | 4.2 | 3.6 |
8 | 4.6 | 5 | 4.8 | 4.1 |
30° Vertical | 45° Vertical | ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
D | C | FC | L | W | D | C | FC | L | W | |
|
|
|
|
|
|
|
|
|
|
|
1.5 | 2.6 | 27 | 3.1 | 1.3 |
| 1.5 | 1.5 | 75 | 1.4 | 0.9 |
2 | 3.5 | 15 | 4.2 | 1.8 |
| 2 | 2.0 | 42 | 1.9 | 1.3 |
3 | 5.2 | 7 | 6.2 | 2.7 |
| 3 | 3.0 | 19 | 2.8 | 1.9 |
4 | 6.9 | 4 | 8.3 | 3.5 |
| 4 | 4.0 | 11 | 3.7 | 2.5 |
Job Information | Type: |
|
|
631 Airport Road, Fall River, MA 02720 • (508)
Lightolier is a Philips group brand