Page 2 of 2 VANDAL RESISTANT, 2'x2' RECESSED FLUORESCENT, STATIC, 2, 3 OR 4 LAMP, T8 OR T12
PHOTOMETRY
MODEL NO. GVS2GFSVK26U |
| LER = FL - 58.9 | IW - 56.4 | BF - 0.87 |
|
|
|
|
| ||||||||||
| Comparative yearly lighting energy cost per 1000 lumens = $4.07 | ||||||||||||||||||
|
| coefficients of utilization — zonal cavity method | (effective floor cavity reflectance 0.20) | ||||||||||||||||
|
| ||||||||||||||||||
|
|
| RF |
|
| 20 |
|
|
|
| 20 |
|
|
|
|
| 20 |
| |
|
| RC |
|
| 80 |
|
|
|
| 50 |
|
|
|
|
| 30 |
| ||
|
| RW | 70 |
| 50 |
| 30 |
| 50 | 30 |
|
| 10 |
| 50 | 30 | 10 | ||
|
| ratio | 1 | 76 |
| 73 |
| 71 |
| 69 | 67 |
|
| 65 |
| 66 | 64 | 63 | |
|
| 3 | 65 |
| 58 |
| 53 |
| 55 | 51 |
|
| 47 |
| 53 | 50 | 47 | ||
|
|
| 2 | 70 |
| 65 |
| 61 |
| 61 | 58 |
|
| 55 |
| 59 | 56 | 54 | |
|
| cavity | 4 | 60 |
| 52 |
| 46 |
| 49 | 45 |
|
| 41 |
| 48 | 44 | 41 | |
|
| 5 | 55 |
| 47 |
| 41 |
| 45 | 40 |
|
| 36 |
| 43 | 39 | 36 | ||
|
| room | 6 | 51 |
| 43 |
| 37 |
| 41 | 36 |
|
| 32 |
| 40 | 35 | 32 | |
|
| 8 | 44 |
| 36 |
| 30 |
| 34 | 29 |
|
| 26 |
| 33 | 29 | 26 | ||
|
|
| 7 | 48 |
| 39 |
| 33 |
| 37 | 32 |
|
| 29 |
| 36 | 32 | 29 | |
|
|
| 9 | 42 |
| 33 |
| 27 |
| 32 | 27 |
|
| 24 |
| 31 | 27 | 23 | |
|
|
| 10 | 39 |
| 30 |
| 25 |
| 29 | 25 |
|
| 22 |
| 29 | 24 | 21 | |
|
| visual comfort probability | (rated lumens per lamp 3150.) |
|
|
|
|
| |||||||||||
|
| room size |
|
|
| ceiling height |
|
|
|
|
| ceiling height |
| ||||||
|
| W |
| L | 8.5 | 10.0 | 13.0 | 16.0 |
|
|
|
| 8.5 | 10.0 | 13.0 16.0 | ||||
|
| 20 |
| 20 |
|
|
| 65 | 69 | 76 | 81 |
|
|
|
| 64 | 68 | 74 | 79 |
| 20 |
| 30 |
|
|
| 58 | 62 | 68 | 73 |
|
|
|
| 56 | 60 | 66 | 71 | |
| 20 |
| 40 |
|
|
| 54 | 58 | 63 | 66 |
|
|
|
| 51 | 55 | 61 | 65 | |
| 20 |
| 60 |
|
|
| 51 | 55 | 58 | 62 |
|
|
|
| 46 | 51 | 55 | 59 | |
|
| 30 |
| 20 |
|
|
| 66 | 70 | 75 | 80 |
|
|
|
| 65 | 69 | 74 | 78 |
| 30 |
| 30 |
|
|
| 58 | 62 | 67 | 71 |
|
|
|
| 56 | 60 | 66 | 69 | |
| 30 |
| 40 |
|
|
| 54 | 57 | 61 | 64 |
|
|
|
| 50 | 54 | 59 | 63 | |
| 30 |
| 60 |
| lengthwise |
| 50 | 53 | 56 | 59 |
|
|
| crosswise | 46 | 50 | 53 | 57 | |
| 40 |
| 40 |
|
| 54 | 57 | 61 | 64 |
|
|
| 51 | 55 | 59 | 63 | |||
| 30 |
| 80 |
|
|
| 49 | 51 | 53 | 56 |
|
|
|
| 44 | 47 | 49 | 53 | |
|
| 40 |
| 20 |
|
|
| 67 | 71 | 76 | 80 |
|
|
|
| 66 | 71 | 75 | 79 |
| 40 |
| 30 |
|
|
| 59 | 63 | 67 | 71 |
|
|
|
| 57 | 62 | 66 | 70 | |
| 40 |
| 60 |
| luminaries |
| 50 | 53 | 55 | 58 |
|
|
| luminaries | 46 | 50 | 53 | 57 | |
| 40 |
| 80 |
|
| 49 | 51 | 52 | 55 |
|
|
| 44 | 47 | 49 | 52 | |||
| 40 |
| 100 |
|
|
| 48 | 50 | 50 | 53 |
|
|
|
| 43 | 45 | 46 | 50 | |
|
| 60 |
| 30 |
|
|
| 60 | 64 | 67 | 71 |
|
|
|
| 58 | 63 | 67 | 70 |
| 60 |
| 40 |
|
|
| 55 | 58 | 61 | 64 |
|
|
|
| 52 | 56 | 59 | 63 | |
| 60 |
| 60 |
|
|
| 51 | 53 | 55 | 58 |
|
|
|
| 47 | 50 | 52 | 56 | |
|
|
|
|
|
|
|
| ||||||||||||
| 60 |
| 80 |
|
|
| 49 | 51 | 51 | 54 |
|
|
|
| 44 | 47 | 48 | 52 | |
| 60 |
| 100 |
|
|
| 48 | 49 | 49 | 52 |
|
|
|
| 43 | 45 | 45 | 49 | |
|
| 100 |
| 40 |
|
|
| 57 | 60 | 62 | 66 |
|
|
|
| 56 | 59 | 61 | 65 |
| 100 |
| 60 |
|
|
| 53 | 55 | 56 | 59 |
|
|
|
| 50 | 53 | 54 | 58 | |
| 100 |
| 80 |
|
|
| 50 | 52 | 52 | 55 |
|
|
|
| 47 | 49 | 50 | 53 | |
|
| 100 |
| 100 |
|
|
| 49 | 50 | 49 | 52 |
|
|
|
| 45 | 46 | 46 | 48 |
ORDERING INFORMATION
Explanation of Catalog Number. Example: GVS2GFSVK26U120SOGLR
GV
S
2 |
|
|
| FS |
| VK |
GUARDSMAN
VANDAL
RESISTANT
STATIC
|
|
|
|
|
|
|
|
|
|
|
|
FIXTURE |
|
| LENS FRAME: |
| LAMP QUANTITY: | ||||||
WIDTH |
| FS= Flat steel frame |
| 2=2 Lamp |
| ||||||
|
|
|
|
|
|
|
|
| 3=3 Lamp |
| |
|
|
|
|
|
|
|
|
| (Not with 6" spacing) | ||
|
|
|
|
|
|
|
|
| 4=4 Lamp |
| |
|
|
|
|
|
|
|
|
| (T8, 2' Lamp Only) LAMP/ | ||
|
|
|
|
|
|
|
|
|
|
| FIXTURE LENGTH: |
|
|
|
| CEILING TYPE: |
|
| LENS/SHIELDING TYPE: | 6U=6"U Lamp T8 or T12 | |||
|
| G= Grid |
|
|
| VK=High impact | 2U=T8, | ||||
|
| F=Flanged (overlap) Z spline |
|
| Prismatic lens | FT=Twin Tube T5 | |||||
|
|
| and plaster frame |
|
|
| (standard) | 17=T8, 2' Lamp | |||
|
|
|
|
|
|
|
|
|
|
| (Nominal 24") |
|
|
|
|
|
|
|
|
|
|
|
Other dimming options. Consult factory.
VOLTAGE: |
|
|
|
| |
| OPTIONS: | ||||
120 or 277 | Add appropriate suffix to | ||||
|
| catalog no., ie: (GLR) | |||
| BALLAST TYPE: |
|
|
| |
LE | <10THD | ||||
|
| <20THD | |||
1 & 2 Lamp Elec. T8 | SO* | HI* | |||
Lamp Elec. T8 | SO* | HI* | |||
Lamp Elec. TT5 | SB* | IB* | |||
| (40 Watt) |
| I3* | ||
Lamp Elec. TT5 | X3* | ||||
Lamp Elec. T8 | O4* | H4* | |||
LOL Dimming (T8) | PS | – | |||
LOL Dimming (TT5) | PB | – |
*Instant Start Standard
OPTIONS & ACCESSORIES
SCREWDRIVER: For holt head screw. Order Catalog Number LP156737.
PLASTER FRAME: Catalog Number PF22.
CONTINUOUS ROW INSTALLATION: For F type fixtures, half width flanges
are required between fixtures. Order Catalog Number: S2FCTRIM (each joint).
RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture
standard. SUFFIX: RF.
FUSING: Internal
ELECTRICAL/WIRING OPTIONS: Consult factory.
DRYWALL KIT: Order Catalog Number: FK92X2.
Request Folio
CHICAGO PLENUM: SUFFIX: CP.
SPECIFICATIONS
PERFORMANCE: In an installation of 2 lamp 31W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .73. To prevent glare the VCP shall be not less than 40 either length- wise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 2144 candelas per square meter. To control veiling reflections, luminaire output in the
SPECIFICATIONS (continued)
MATERIALS: Chassis parts are
FINISH: Chassis
ELECTRICAL: Thermally protected class "P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.
LABELS: I.B.E.W./UL and
Job Information |
| Type: |
|
|
|
Lightolier a Genlyte Thomas Company | www.lightolier.com |
Technical Information: (978)
631 Airport Road, Fall River, MA 02720 • (508)