PHOTOMETRY
Section 6A/Folio P20-51

GUARDSMAN GVS SERIES 2X2

Page 2 of 2 VANDAL RESISTANT, 2'x2' RECESSED FLUORESCENT, STATIC, 2, 3 OR 4 LAMP, T8 OR T12

PHOTOMETRY

MODEL NO. GVS2GFSVK26U

 

LER = FL - 58.9

IW - 56.4

BF - 0.87

 

 

 

 

 

 

Comparative yearly lighting energy cost per 1000 lumens = $4.07

 

 

coefficients of utilization — zonal cavity method

(effective floor cavity reflectance 0.20)

 

 

 

 

 

RF

 

 

20

 

 

 

 

20

 

 

 

 

 

20

 

 

 

RC

 

 

80

 

 

 

 

50

 

 

 

 

 

30

 

 

 

RW

70

 

50

 

30

 

50

30

 

 

10

 

50

30

10

 

 

ratio

1

76

 

73

 

71

 

69

67

 

 

65

 

66

64

63

 

 

3

65

 

58

 

53

 

55

51

 

 

47

 

53

50

47

 

 

 

2

70

 

65

 

61

 

61

58

 

 

55

 

59

56

54

 

 

cavity

4

60

 

52

 

46

 

49

45

 

 

41

 

48

44

41

 

 

5

55

 

47

 

41

 

45

40

 

 

36

 

43

39

36

 

 

room

6

51

 

43

 

37

 

41

36

 

 

32

 

40

35

32

 

 

8

44

 

36

 

30

 

34

29

 

 

26

 

33

29

26

 

 

 

7

48

 

39

 

33

 

37

32

 

 

29

 

36

32

29

 

 

 

9

42

 

33

 

27

 

32

27

 

 

24

 

31

27

23

 

 

 

10

39

 

30

 

25

 

29

25

 

 

22

 

29

24

21

 

 

visual comfort probability

(rated lumens per lamp 3150.)

 

 

 

 

 

 

 

room size

 

 

 

ceiling height

 

 

 

 

 

ceiling height

 

 

 

W

 

L

8.5

10.0

13.0

16.0

 

 

 

 

8.5

10.0

13.0 16.0

 

 

20

 

20

 

 

 

65

69

76

81

 

 

 

 

64

68

74

79

 

20

 

30

 

 

 

58

62

68

73

 

 

 

 

56

60

66

71

 

20

 

40

 

 

 

54

58

63

66

 

 

 

 

51

55

61

65

 

20

 

60

 

 

 

51

55

58

62

 

 

 

 

46

51

55

59

 

 

30

 

20

 

 

 

66

70

75

80

 

 

 

 

65

69

74

78

 

30

 

30

 

 

 

58

62

67

71

 

 

 

 

56

60

66

69

 

30

 

40

 

 

 

54

57

61

64

 

 

 

 

50

54

59

63

 

30

 

60

 

lengthwise

 

50

53

56

59

 

 

 

crosswise

46

50

53

57

 

40

 

40

 

 

54

57

61

64

 

 

 

51

55

59

63

 

30

 

80

 

 

 

49

51

53

56

 

 

 

 

44

47

49

53

 

 

40

 

20

 

 

 

67

71

76

80

 

 

 

 

66

71

75

79

 

40

 

30

 

 

 

59

63

67

71

 

 

 

 

57

62

66

70

 

40

 

60

 

luminaries

 

50

53

55

58

 

 

 

luminaries

46

50

53

57

 

40

 

80

 

 

49

51

52

55

 

 

 

44

47

49

52

 

40

 

100

 

 

 

48

50

50

53

 

 

 

 

43

45

46

50

 

 

60

 

30

 

 

 

60

64

67

71

 

 

 

 

58

63

67

70

 

60

 

40

 

 

 

55

58

61

64

 

 

 

 

52

56

59

63

 

60

 

60

 

 

 

51

53

55

58

 

 

 

 

47

50

52

56

 

 

 

 

 

 

 

 

 

60

 

80

 

 

 

49

51

51

54

 

 

 

 

44

47

48

52

 

60

 

100

 

 

 

48

49

49

52

 

 

 

 

43

45

45

49

 

 

100

 

40

 

 

 

57

60

62

66

 

 

 

 

56

59

61

65

 

100

 

60

 

 

 

53

55

56

59

 

 

 

 

50

53

54

58

 

100

 

80

 

 

 

50

52

52

55

 

 

 

 

47

49

50

53

 

 

100

 

100

 

 

 

49

50

49

52

 

 

 

 

45

46

46

48

ORDERING INFORMATION

Explanation of Catalog Number. Example: GVS2GFSVK26U120SOGLR

GV

S

2

 

 

 

FS

 

VK

GUARDSMAN

VANDAL

RESISTANT

STATIC

 

 

 

 

 

 

 

 

 

 

 

 

FIXTURE

 

 

LENS FRAME:

 

LAMP QUANTITY:

WIDTH

 

FS= Flat steel frame

 

2=2 Lamp

 

 

 

 

 

 

 

 

 

 

3=3 Lamp

 

 

 

 

 

 

 

 

 

 

(Not with 6" spacing)

 

 

 

 

 

 

 

 

 

4=4 Lamp

 

 

 

 

 

 

 

 

 

 

(T8, 2' Lamp Only) LAMP/

 

 

 

 

 

 

 

 

 

 

 

FIXTURE LENGTH:

 

 

 

 

CEILING TYPE:

 

 

LENS/SHIELDING TYPE:

6U=6"U Lamp T8 or T12

 

 

G= Grid (lay-in T bar)

 

 

 

VK=High impact

2U=T8, 1-5/8" U Lamp

 

 

F=Flanged (overlap) Z spline

 

 

Prismatic lens

FT=Twin Tube T5

 

 

 

and plaster frame

 

 

 

(standard)

17=T8, 2' Lamp

 

 

 

 

 

 

 

 

 

 

 

(Nominal 24")

 

 

 

 

 

 

 

 

 

 

 

Other dimming options. Consult factory.

VOLTAGE:

 

 

 

 

 

OPTIONS:

120 or 277

Add appropriate suffix to

 

 

catalog no., ie: (GLR)

 

BALLAST TYPE:

 

 

 

1-2 Lamp Mag. T12

LE

<10THD

 

 

<20THD

1 & 2 Lamp Elec. T8

SO*

HI*

1-2

Lamp Elec. T8

SO*

HI*

1-2

Lamp Elec. TT5

SB*

IB*

 

(40 Watt)

 

I3*

1-3

Lamp Elec. TT5

X3*

1-4

Lamp Elec. T8

O4*

H4*

LOL Dimming (T8)

PS

LOL Dimming (TT5)

PB

*Instant Start Standard

OPTIONS & ACCESSORIES

SCREWDRIVER: For holt head screw. Order Catalog Number LP156737.

PLASTER FRAME: Catalog Number PF22.

CONTINUOUS ROW INSTALLATION: For F type fixtures, half width flanges

are required between fixtures. Order Catalog Number: S2FCTRIM (each joint).

RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture

standard. SUFFIX: RF.

FUSING: Internal fast-blow fusing. SUFFIX: GLR. Internal slow-blow fusing. SUFFIX: GMF.

ELECTRICAL/WIRING OPTIONS: Consult factory.

DRYWALL KIT: Order Catalog Number: FK92X2.

Request Folio OA30-10.

CHICAGO PLENUM: SUFFIX: CP.

SPECIFICATIONS

PERFORMANCE: In an installation of 2 lamp 31W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .73. To prevent glare the VCP shall be not less than 40 either length- wise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 2144 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 66.0%.

SPECIFICATIONS (continued)

MATERIALS: Chassis parts are die-formed code gauge cold rolled steel. Housing with side rails hemmed over and housing ends turned-in for safe han- dling.

FINISH: Chassis exterior—black baked polyester enamel. Cavity—white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. LENS: (VK) prismatic lens is 3/16" thick, pattern 12, minimum impact strength, 130 foot pounds.

ELECTRICAL: Thermally protected class "P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

LABELS: I.B.E.W./UL and C-UL.

Job Information

 

Type:

 

 

 

Lightolier a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902