Lightolier GVS Series 2X4 Photometry, Ordering Information, Options & Accessories, Specifications

Models: GVS Series 2X4

1 2
Download 2 pages 36.33 Kb
Page 2
Image 2
PHOTOMETRY
Section 6A/Folio P20-52

GUARDSMAN GVS SERIES 2X4

Page 2 of 2 VANDAL RESISTANT, 2'x4' RECESSED FLUORESCENT, STATIC, 2, 3 OR 4 LAMP, T8 OR T12

PHOTOMETRY

MODEL NO. GVS2GFSVK432

 

LER = FL - 69.0

IW - 105

BF - 0.86

 

 

 

 

 

 

Comparative yearly lighting energy cost per 1000 lumens = $3.48

 

 

coefficients of utilization — zonal cavity method

(effective floor cavity reflectance 0.20)

 

 

 

 

 

RF

 

 

20

 

 

 

 

20

 

 

 

 

 

20

 

 

 

RC

 

 

80

 

 

 

 

50

 

 

 

 

 

30

 

 

 

RW

70

 

50

 

30

 

50

30

 

 

10

 

50

30

10

 

 

ratio

1

82

 

79

 

76

 

74

72

 

 

70

 

71

69

68

 

 

3

69

 

62

 

56

 

59

54

 

 

51

 

57

53

50

 

 

 

2

75

 

70

 

65

 

66

62

 

 

59

 

63

60

58

 

 

cavity

4

64

 

56

 

50

 

53

48

 

 

44

 

51

47

43

 

 

5

59

 

50

 

44

 

48

43

 

 

39

 

46

42

38

 

 

room

6

55

 

45

 

39

 

43

38

 

 

34

 

42

38

34

 

 

8

47

 

38

 

32

 

36

31

 

 

28

 

36

31

27

 

 

 

7

51

 

41

 

35

 

40

34

 

 

31

 

39

34

30

 

 

 

9

44

 

35

 

29

 

34

29

 

 

25

 

33

28

25

 

 

 

10

42

 

32

 

27

 

31

26

 

 

23

 

31

26

23

 

 

visual comfort probability

(rated lumens per lamp 3150.)

 

 

 

 

 

 

 

room size

 

 

 

ceiling height

 

 

 

 

 

ceiling height

 

 

 

W

 

L

8.5

10.0

13.0

16.0

 

 

 

 

8.5

10.0

13.0 16.0

 

 

20

 

20

 

 

 

63

67

74

79

 

 

 

 

62

66

73

78

 

20

 

30

 

 

 

56

60

65

70

 

 

 

 

54

59

64

69

 

20

 

40

 

 

 

52

55

60

64

 

 

 

 

49

53

59

63

 

20

 

60

 

 

 

49

52

55

59

 

 

 

 

45

49

53

58

 

 

30

 

20

 

 

 

63

68

73

78

 

 

 

 

63

67

72

77

 

30

 

30

 

 

 

56

60

64

69

 

 

 

 

54

59

64

68

 

30

 

40

 

 

 

51

55

58

62

 

 

 

 

49

53

57

61

 

30

 

60

 

lengthwise

 

48

51

53

57

 

 

 

crosswise

44

48

51

55

 

40

 

40

 

 

52

55

59

62

 

 

 

50

53

57

61

 

30

 

80

 

 

 

46

49

50

54

 

 

 

 

42

45

48

52

 

 

40

 

20

 

 

 

65

69

74

78

 

 

 

 

64

69

73

77

 

40

 

30

 

 

 

57

61

65

68

 

 

 

 

55

60

64

68

 

40

 

60

 

luminaries

 

48

51

53

56

 

 

 

luminaries

45

48

51

55

 

40

 

80

 

 

46

49

49

53

 

 

 

43

45

47

51

 

40

 

100

 

 

 

46

48

48

50

 

 

 

 

42

44

45

48

 

 

60

 

30

 

 

 

57

61

65

69

 

 

 

 

57

61

65

68

 

60

 

40

 

 

 

52

55

58

62

 

 

 

 

51

54

58

61

 

60

 

60

 

 

 

48

51

52

56

 

 

 

 

46

48

51

54

 

 

 

 

 

 

 

 

 

60

 

80

 

 

 

46

48

49

52

 

 

 

 

43

45

46

50

 

60

 

100

 

 

 

46

47

47

49

 

 

 

 

42

43

44

47

 

 

100

 

40

 

 

 

55

58

60

64

 

 

 

 

54

57

60

63

 

100

 

60

 

 

 

51

52

53

57

 

 

 

 

49

51

52

56

 

100

 

80

 

 

 

48

50

50

53

 

 

 

 

46

47

48

51

 

 

100

 

100

 

 

 

47

48

47

50

 

 

 

 

44

45

45

47

ORDERING INFORMATION

Explanation of Catalog Number. Example: GVS2GFSVK432120O4GLR

GV

GUARDSMAN

VANDAL

RESISTANT

S

STATIC

 

2

 

 

 

 

 

FS

 

VK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIXTURE

 

 

 

 

LENS FRAME:

 

 

 

LAMP

 

WIDTH

 

 

 

 

FS= Flat steel frame

 

 

 

QUANTITY:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2=2 Lamp

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3=3 Lamp

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4=4 Lamp

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CEILING TYPE:

LENS/SHIELDING TYPE:

LAMP/

G= Grid (lay-in T bar)

VK= High impact

FIXTURE LENGTH:

F=Flanged (overlap) Z spline

Prismatic lens

32=T8

and plaster frame

(standard)

34=T12

 

 

(Nominal 48")

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VOLTAGE:

 

 

 

 

 

OPTIONS:

120 or 277

 

 

 

 

Add appropriate suffix

 

 

 

 

 

 

 

to catalog no., ie: (GLR)

 

 

 

 

 

 

 

 

 

BALLAST TYPE:

1 & 2 Lamp Mag. T12

LE

2-2 Lamp Mag. T12

LE

<20THD <10THD

1 & 2 Lamp Elec. T8

SO*

HI*

2-2 Lamp Elec. T8

SO*

HI*

1-3 Lamp Elec. T8

O3*

H3*

1-4 Lamp Elec. T8

O4*

H4*

LOL T8 Dimming

PS

 

*Instant Start Standard

 

 

Other dimming options. Consult factory.

OPTIONS & ACCESSORIES

SCREWDRIVER: For holt head screw. Order Catalog Number LP156737.

PLASTER FRAME: Catalog Number PF24.

CONTINUOUS ROW INSTALLATION: For F type fixtures, half width flanges

are required between fixtures. Order Catalog Number: S2FCTRIM (each joint).

RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture

standard. SUFFIX: RF.

FUSING: Internal fast-blow fusing. SUFFIX: GLR. Internal slow-blow fusing. SUFFIX: GMF.

ELECTRICAL/WIRING OPTIONS: Consult factory.

DRYWALL KIT: Order Catalog Number: FK92X4.

(Request Folio OA30-10).

CHICAGO PLENUM: SUFFIX: CP.

SPECIFICATIONS

PERFORMANCE: In an installation of 4 lamp 32W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .79. To prevent glare the VCP shall be not less than 46 either length- wise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 2321 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 66.8%.

SPECIFICATIONS (continued)

MATERIALS: Chassis parts are die-formed code gauge cold rolled steel. Housing with side rails hemmed over and housing ends turned-in for safe handling.

FINISH: Chassis exterior—black baked polyester enamel. Cavity—white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. LENS: (VK) prismatic lens is 3/16" thick pattern 12, minimum impact strength, 130 foot pounds.

ELECTRICAL: Thermally protected class "P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

LABELS: I.B.E.W./UL and C-UL.

Job Information

 

Type:

 

 

 

Lightolier a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902

Page 2
Image 2
Lightolier GVS Series 2X4 Photometry, Ordering Information, Options & Accessories, Specifications, Guardsman Gvs Series