Lightolier H9S2GLR217 Page 2 of, Ordering Information, Options/Accessories, Specifications, Type

Models: H9S2GLR117 H9S2GLR217

1 2
Download 2 pages 29.19 Kb
Page 2
Image 2
Page 2 of 2

 

HP90 Recessed Fluorescent H9S2GLR117 or 217

Page 2 of 2

Direct/Indirect – 2' x 2' with Acrylic Linear Prismatic Lens

 

Static, 2 Lamp T8

Model No. H9S2GLR117120SO

LER = FP - 48.7 IW - 17.96 BF - 0.88 Comparative yearly lighting ene gy cost per

1000 lumens = $4.92

Report Number: G2007124

Catalog Number: H9S2GLR117120SO

Lamps: (1) F17 T8

Luminaire: HP90 2' x 2' with linear prismatic lens.

Ballast: REL1P-32-SC (Advance)

Report is based on 1375 Lumens per lamp. Efficiency: 72.5%

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.2

 

 

1.4

Shielding Angles:

 

 

90

 

 

90

Plane:

 

 

 

 

0-Deg

 

90-Deg

Luminous Length:

 

22.800

 

22.800

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.20

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

1

79

75

72

70

68

66

68

66

64

2

71

65

60

61

57

54

59

55

52

3

65

57

51

53

48

44

51

47

44

4

59

50

43

47

42

38

45

41

37

5

54

44

38

42

36

32

41

36

32

6

50

40

33

38

32

28

37

32

28

7

46

36

30

34

29

25

33

28

24

8

43

33

27

31

26

22

30

25

22

9

40

30

24

29

23

20

28

23

20

10

38

28

22

27

21

18

26

21

18

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG. 45-DEG. 90-DEG.

45

708.

879.

1023.

55

624.

891.

1112.

65

509.

910.

1267.

75

385.

925.

1185.

85

247.

247.

216.

CANDELA DISTRIBUTION

 

0.0

45.0

90.0

FLUX

0

316

316

316

 

5

314

315

317

30

15

298

307

314

87

25

271

290

307

134

35

233

265

292

165

45

186

231

269

177

55

133

190

237

168

65

80

143

199

140

75

37

89

114

85

85

8

8

7

12

90

2

2

1

 

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

0- 30

250

18 2

25 1

0- 40

416

30 2

41 7

0- 60

760

55 3

76 3

0- 90

997

72 5

100 0

90-180

0

0 0

0 0

0-180

997

72 5

100 0

Model No. H9S2GLR217120SO

LER = FP - 56.6 IW - 31.9 BF - 0.88 Comparative yearly lighting ene gy cost per

1000 lumens = $4.24

Report Number: G2007120

Catalog Number: H9S2GLR217120SO

Lamps: (2) F17 T8

Luminaire: HP90 2' x 2' with linear prismatic lens.

Ballast: B232I120RH-A (Universal)

Report is based on 1375 Lumens per lamp. Efficiency: 74.6%

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.2

 

 

1.5

Shielding Angles:

 

 

90

 

 

90

Plane:

 

 

 

 

0-Deg

 

90-Deg

Luminous Length:

 

22.800

 

22.800

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.20

 

 

 

 

 

 

 

 

 

 

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

1

81

77

74

72

70

67

69

67

65

2

73

67

61

63

58

55

60

57

54

3

66

58

52

55

49

45

52

48

45

4

60

51

44

48

43

38

46

42

38

5

55

45

38

43

37

33

41

36

32

6

51

41

34

39

33

28

37

32

28

7

47

37

30

35

29

25

34

29

25

8

44

33

27

32

26

22

31

26

22

9

41

31

24

29

24

20

28

23

20

10

38

28

22

27

22

18

26

21

18

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE IN DEG. 0-DEG. 45-DEG. 90-DEG.

45 1453. 1834. 2142.

55 1294. 1899. 2303.

65 1044. 1967. 2591.

75 759. 2006. 2390.

85 494. 525. 432.

CANDELA DISTRIBUTION

 

0.0

45.0

90.0

FLUX

0

615

615

615

 

5

612

615

617

59

15

586

605

618

171

25

539

580

616

267

35

470

538

603

337

45

382

482

563

368

55

276

405

491

353

65

164

309

407

294

75

73

193

230

177

85

16

17

14

26

90

3

2

2

 

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

0- 30

496

18 1

24 2

0- 40

833

30 3

40 6

0- 60

1555

56 5

75 8

0- 90

2052

74 6

100 0

90-180

0

0 0

0 0

0-180

2052

74 6

100 0

Ordering Information

Explanation of Catalog Number. Example: H9S2GLR217UNVHI

 

 

 

 

S

 

2

 

 

 

 

 

 

 

 

 

 

HP90

 

Body Style:

 

Fixture

Direct/Indi ect

 

S = Static

 

Width

 

Recessed

 

 

 

 

 

 

 

 

 

 

 

 

 

H9

Standard HP90

 

 

 

 

 

 

 

HY

For NYC Code – I B.E.W. Manufactured

G

 

L

Ceiling

 

Type:

 

 

 

Ac ylic Lens

Fits both

 

 

Standard Grid

 

 

and

 

 

Slot Grid

 

 

R

Reflector:

Specular

Aluminum

 

 

 

17

 

 

 

 

Lamp

Lamp:

Quantity

(By Others)

1=1 Lamp

17=T8 17W

2=2 Lamp

(Nominal 24")

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage:

 

 

 

Options:

120, 277 or

 

 

Add appropriate

UNV=120-277

 

 

suffix to catalog

 

 

 

 

 

 

 

no., ie: (GLR)

 

 

 

Ballast

Type:

 

 

 

 

 

 

 

 

<20THD <10THD

1 or 2 Lamp Elec. T8

 

SO *

 

HI *

LOL Dimming T8

 

PS

 

*Instant Start Standard

Other dimming options. Consult factory.

NOTE: For T8 UNV, you must use HI Ballast Code.

HN

For NYC Code – Local 3 Manufactu ed

Options/Accessories

Fusing: Internal fast blow fusing: SUFFIX: GLR.

Internal slow blow fusing: SUFFIX: GMF.

Drywall Kit: Order Catalog Number: FK92X2 .

Electrical Wiring Options: Consult factory.For motion or light sensor. See Folio OA20-10.

Specifications

Performance: In an installation of 2 lamp 17W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .89. To reduce glare the average brightness at 65° shall not exceed 2591 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 75.8%.

Materials: Chassis parts are die-formed code gauge steel.

Lamp Shield: Linear prismatic translucent DR acrylic lens.

Finish: Chassis exterior – baked white polyester enamel. Cavity – baked white polyester enamel. Rust preventative undercoating. Reflector – low irides- cence specular aluminum .95% reflectance.

Specifications (continued)

Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed.

This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org

 

Job Information

Type:

 

 

 

Lightolier a Genlyte company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2007 a Genlyte company

Section 5/Folio M32-17

Page 2
Image 2
Lightolier H9S2GLR217 Page 2 of, Ordering Information, Options/Accessories, Specifications continued, Job Information