Lightolier HDS2GLW128 Ordering Information, Options/Accessories, Specifications, Page 2 of

Models: HDS2GLW228 HDS2GLW128

1 2
Download 2 pages 39.09 Kb
Page 2
Image 2
Page 2 of 2

HP90 Semi HDS2GLW128 or 228

Page 2 of 2

Direct/Indirect Semi-Recessed Fluorescent 2' x 4' with Acrylic Linear Prismatic Lens, 1 or 2 Lamp T5

Model No. HDS2GLW128UNVPG

LER = FP - 74.7 IW - 33.3 BF - 1.04 Comparative yearly lighting energy cost per

1000 lumens = $3.21

Report Number: G2008221

Catalog Number: HDS2GLW128UNVPG

Lamps: (1) F28 T5

Luminaire: HP90 Semi-Recessed 2' x 4' with linear prismatic lens.

Ballast: ICN-2S28

Report is based on 2750 Lumens per lamp.

Efficiency: 87.0%

 

 

CIE Type-Direct-Indirect

 

Plane:

0-Deg

90-Deg

Spacing Criteria:

1.2

1.4

Shielding Angles:

90

90

Plane:

0-Deg

90-Deg

Luminous Length:

47.880

23.040

CANDELA DISTRIBUTION0

 

0.0

45.0

90.0

FLUX

0

679

679

679

 

5

675

676

678

64

15

645

657

668

186

25

587

619

645

285

35

507

563

607

351

45

408

495

561

378

55

295

417

505

366

65

179

336

440

320

75

81

256

370

255

85

18

184

307

187

90

4

121

225

 

 

 

 

 

 

Model No. HDS2GLW228120WA

LER = FP - 83.7 IW - 54.1 BF - 0.93 Comparative yearly lighting energy cost per

1000 lumens = $2.87

Report Number: G2008223

Catalog Number: HDS2GLW228120WA

Lamps: (2) F28 T5

Luminaire: HP90 Semi-Recessed 2' x 4' with linear prismatic lens.

Ballast: ST232120E (WA)

Report is based on 2750 Lumens per lamp.

Efficiency: 88.5%

 

 

CIE Type-Direct-Indirect

 

Plane:

0-Deg

90-Deg

Spacing Criteria:

1.2

1.4

Shielding Angles:

90

90

Plane:

0-Deg

90-Deg

Luminous Length:

47.880

23.040

CANDELA DISTRIBUTION

 

0.0

45.0

90.0

FLUX

0

1396

1397

1396

 

5

1388

1390

1394

132

15

1325

1347

1368

381

25

1207

1266

1315

583

35

1042

1150

1241

718

45

840

1011

1150

775

55

608

855

1034

751

65

370

688

892

655

75

170

517

729

513

85

37

363

573

357

90

7

222

404

 

 

 

 

 

 

COEFFICIENTS OF UTILIZATION – ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

01

92

87

82

81

77

74

77

74

71

02

83

74

67

69

64

59

66

62

58

03

75

64

56

60

54

48

58

52

48

04

68

57

48

53

46

41

51

45

40

05

63

50

42

47

40

35

46

39

34

06

58

45

37

43

36

30

41

35

30

07

53

41

33

39

32

27

37

31

26

08

50

37

29

35

29

24

34

28

24

09

46

34

27

32

26

21

32

25

21

10

43

31

24

30

24

19

29

23

19

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

00-030

535

19.5

22.4

00-040

886

32.2

37.1

00-060

1630

59.3

68.1

00-090

2392

87.0

100.0

90-180

0000

00.0

000.0

00-180

2392

87.0

100.0

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG. 45-DEG. 90-DEG.

45

774.

916.

1014.

55

676.

924.

1083.

65

540.

965.

1206.

75

373.

1091.

1466.

85

188.

1614.

2322.

COEFFICIENTS OF UTILIZATION – ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

01

94

88

83

82

79

75

79

76

73

02

84

76

69

71

65

60

68

63

59

03

76

66

58

61

55

50

59

53

49

04

69

58

49

54

47

42

52

46

41

05

64

51

43

48

41

36

47

40

35

06

59

46

38

44

36

31

42

36

31

07

54

42

33

39

32

27

38

32

27

08

51

38

30

36

29

24

35

29

24

09

47

35

27

33

26

22

32

26

22

10

44

32

25

31

24

20

30

24

20

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

00-030

1097

19.9

22.5

00-040

1815

33.0

37.3

00-060

3340

60.7

68.7

00-090

4866

88.5

100.0

90-180

0000

0.0

000.0

00-180

4866

88.5

100.0

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG. 45-DEG. 90-DEG.

45

1593.

1871.

2079.

55

1394.

1895.

2218.

65

1116.

1976.

2446.

75

783.

2203.

2889.

85

386.

3183.

4333.

Ordering Information

Explanation of Catalog Number. Example: HDS2GLW228UNVPG

HD

S

2

G

L

W

28

 

 

 

 

 

 

 

 

Reflector:

Lamp

 

 

 

 

 

 

 

 

 

HP90

Body Style:

Fixture

Ceiling

 

Type:

Acrylic Lens

 

 

 

 

 

 

 

 

 

 

Lamp:

Voltage:

 

 

Options:

Direct/Indirect

S = Static

Width

Fits both

 

White

Quantity

 

(By Others)

120, 277 or

 

 

Add appropriate

Semi-Recessed

 

 

Standard Grid

 

 

1=1 Lamp

28=T5 288W

UNV=120-277

 

 

suffix to catalog

 

 

 

and

 

 

2=2 Lamp

 

(Nominal 48")

Ballast

Type:

no., ie: (A)

 

 

 

Slot Grid

 

 

 

 

 

 

 

 

 

<20THD

<10THD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1 or 2 Lamp Elec. T5

PI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(28 Watt)

 

 

PG ††

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1 or 2 Lamp Elec. T5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(28 Watt)

 

 

 

Options/Accessories

Fusing: Internal fast blow fusing: SUFFIX: A.

Internal slow blow fusing: SUFFIX: C.

Drywall Kit: Order Catalog Number: FK92X4.

Electrical Wiring Options: Consult factory.For motion or light sensor. See Folio OA20-10.

Specifications

Performance: In an installation of 2 lamp 28W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .88. To reduce glare the average brightness at 65° shall not exceed 2446 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 77.6%.

Materials: Chassis parts are die-formed code gauge steel.

Lamp Shield: Linear prismatic translucent DR acrylic lens.

Finish: Chassis exterior – Soft white post painted polyester powder. Cavity – Soft white post painted polyester powder. Rust preventative undercoating. Reflector – Soft white post painted polyester powder.

*2-Lamp Elect. T5

VY**

(28 Watt)

 

 

.95/.35 Bilevel Step Ballast

 

 

†Instant Start (120, 227 or UNV) ††Program Rapid Start (UNV only)

*WA = Linear T5 Instant Start Less than 10 THD 56 Input Watts 0.93 Ballast Factor 120V or 277V only.

**.35 20THD / .95 10 THD

Specifications (continued)

Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed.

This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org

Job Information Type:

For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

www.lightolier.com © 2008 a Philips Group

Section 5/Folio M33-40

Lightolier is a Philips group brand

Page 2
Image 2
Lightolier HDS2GLW128, HDS2GLW228 Ordering Information, Options/Accessories, Specifications continued, Page 2 of