Lightolier HDS2GLW154 Ordering Information, Options/Accessories, Specifications, Page 2 of

Models: HDS2GLW254 HDS2GLW154

1 2
Download 2 pages 37.81 Kb
Page 2
Image 2
Page 2 of 2

HP90 Semi HDS2GLW154 or 254

Page 2 of 2

Direct/Indirect Semi-Recessed Fluorescent 2' x 4' with Acrylic Linear Prismatic Lens, 1 or 2 Lamp T5

Model No. HDS2GLW154UNVPG

LER = FP - 60.5 IW - 60.8 BF - 1.0 Comparative yearly lighting energy cost per

1000 lumens = $3.97

Report Number: G2008213

Catalog Number: HDS2GLW154UNVPG

Lamps: (1) F54 T5 HO

Luminaire: HP90 Semi-Recessed 2' x 4' with linear prismatic lens.

Ballast: QT1X54/120PHO

Report is based on 4400 Lumens per lamp. Efficiency: 83.6%

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.2

 

 

1.4

Shielding Angles:

 

 

90

 

 

90

Plane:

 

 

 

 

0-Deg

 

90-Deg

Luminous Length:

 

47.880

 

23.040

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.200

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

01

88

83

79

78

74

71

74

71

69

02

79

71

65

67

61

57

64

59

55

03

72

62

54

58

52

47

56

50

46

04

66

54

46

51

44

39

49

43

39

05

60

48

40

46

39

34

44

38

33

06

55

43

35

41

34

29

40

34

29

07

51

39

31

37

31

26

36

30

25

08

48

36

28

34

28

23

33

27

23

09

45

33

26

31

25

21

30

25

20

10

42

30

23

29

23

19

28

22

18

CANDELA DISTRIBUTION

 

0.0

45.0

90.0

FLUX

0

1053

1053

1053

 

5

1046

1047

1051

100

15

997

1015

1033

287

25

906

955

996

440

35

781

868

937

541

45

626

760

864

581

55

452

641

777

562

65

272

516

677

492

75

121

392

568

391

85

26

282

469

284

90

5

179

338

 

 

 

 

 

 

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

00-030

827

18.8

22.5

00-040

1368

31.1

37.2

00-060

2511

57.1

68.3

00-090

3678

83.6

100.0

90-180

0000

0.0

000.0

00-180

3678

83.6

100.0

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG. 45-DEG. 90-DEG.

45

1187.

1407.

1562.

55

1036.

1421.

1667.

65

820.

1482.

1856.

75

558.

1670.

2251.

85

271.

2473.

3547.

Model No. HDS2GLW254UNVPG

LER = FP - 71.5 IW - 93.9 BF - 1.02 Comparative yearly lighting energy cost per

1000 lumens = $3.36

Report Number: G2008216

Catalog Number: HDS2GLW254UNVPG

Lamps: (2) F54 T5 HO

Luminaire: HP90 Semi-Recessed 2' x 4' with linear prismatic lens

Ballast: B254PUNV-D

Report is based on 4400 Lumens per lamp. Efficiency: 74.8%

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.2

 

 

1.4

Shielding Angles:

 

 

90

 

 

90

Plane:

 

 

 

 

0-Deg

 

90-Deg

Luminous Length:

 

47.880

 

23.040

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.200

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

01

79

75

71

70

67

64

67

64

62

02

71

64

58

60

55

51

57

53

50

03

64

56

49

52

46

42

50

45

41

04

59

49

42

46

40

35

44

39

35

05

54

43

36

41

35

30

39

34

30

06

50

39

32

37

31

26

36

30

26

07

46

35

28

33

27

23

32

27

23

08

43

32

25

31

25

21

30

24

20

09

40

29

23

28

22

18

27

22

18

10

37

27

21

26

20

17

25

20

17

CANDELA DISTRIBUTION0

 

0.0

45.0

90.0

FLUX

0

1891

1891

1891

 

5

1879

1881

1888

179

15

1794

1825

1852

516

25

1635

1713

1779

789

35

1410

1556

1679

972

45

1135

1367

1553

1047

55

822

1155

1397

1014

65

502

928

1204

885

75

230

699

992

695

85

50

494

782

486

90

9

302

547

 

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

00-030

1484

16.9

22.5

00-040

2456

27.9

37.3

00-060

4517

51.3

68.6

00-090

6583

74.8

100.0

90-180

0000

00.0

000.0

00-180

6583

74.8

100.0

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE IN DEG. 0-DEG. 45-DEG. 90-DEG.

45 2152. 2530. 2807.

55 1885. 2560. 2997.

65 1514. 2665. 3301.

75 1060. 2979. 3931.

85 522. 4332. 5914.

Ordering Information

Explanation of Catalog Number. Example: HDS2GLW254UNVPG

 

HD

 

S

 

2

 

G

 

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HP90

Body Style:

 

Fixture

Ceiling

Type:

Acrylic Lens

Direct/Indirect

S = Static

 

Width

 

Fits both

 

 

Semi-Recessed

 

 

 

 

 

 

Standard Grid

 

 

 

 

 

 

 

 

 

 

 

 

and

 

 

 

 

 

 

 

 

 

 

 

 

Slot Grid

 

 

W

Reflector:

White

 

 

 

54

 

UNV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lamp

Lamp:

Voltage:

 

 

 

Options:

Quantity

(By Others)

UNV=120-277

 

 

Add appropriate

1=1 Lamp

54=T5 54W

 

 

 

 

 

 

suffix to catalog

2=2 Lamp

(Nominal 48")

 

 

 

 

 

 

 

no., ie: (A)

 

 

 

 

 

 

 

 

 

Ballast Type:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<20THD <10THD

 

 

 

 

 

 

1 Lamp Elec. T5 HO

 

PG ††

 

 

 

 

 

 

 

(54 Watt)

 

 

PG ††

 

 

 

 

 

 

2 Lamp Elec. T5 HO

 

 

 

 

 

 

 

 

(54 Watt)

 

 

 

 

 

 

 

 

 

 

 

††Program Rapid Start (UNV only)

 

 

 

 

Options/Accessories

Fusing: Internal fast blow fusing: SUFFIX: A.

Internal slow blow fusing: SUFFIX: C.

Drywall Kit: Order Catalog Number: FK92X4.

Electrical Wiring Options: Consult factory.For motion or light sensor: See Folio OA20-10.

Specifications

Performance: In an installation of 2 lamp 54W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .75. To reduce glare the average brightness at 65° shall not exceed 3301 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 77.5%.

Materials: Chassis parts are die-formed code gauge steel.

Lamp Shield: Linear prismatic translucent DR acrylic lens.

Finish: Chassis exterior – Soft white post painted polyester powder. Cavity – Soft white post painted polyester powder. Rust preventative undercoating. Reflector – Soft white post painted polyester powder.

Lightolier is a Philips group brand

Specifications (continued)

Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed.

This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org

Job Information Type:

For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

www.lightolier.com © 2008 a Philips Group

Section 5/Folio M33-45

Page 2
Image 2
Lightolier HDS2GLW154, HDS2GLW254 Ordering Information, Options/Accessories, Specifications continued, Page 2 of