HP90 Semi HDS2GLW154 or 254
Page 2 of 2
Direct/Indirect
Model No. HDS2GLW154UNVPG
LER = FP - 60.5 IW - 60.8 BF - 1.0 Comparative yearly lighting energy cost per
1000 lumens = $3.97
Report Number: G2008213
Catalog Number: HDS2GLW154UNVPG
Lamps: (1) F54 T5 HO
Luminaire: HP90
Ballast: QT1X54/120PHO
Report is based on 4400 Lumens per lamp. Efficiency: 83.6%
CIE |
|
|
|
| |||||
Plane: |
|
|
|
|
| ||||
Spacing Criteria: |
|
| 1.2 |
|
| 1.4 | |||
Shielding Angles: |
|
| 90 |
|
| 90 | |||
Plane: |
|
|
|
|
| ||||
Luminous Length: |
| 47.880 |
| 23.040 | |||||
COEFFICIENTS OF UTILIZATION – |
|
| |||||||
ZONAL CAVITY METHOD. EFFECTIVE |
| ||||||||
FLOOR CAVITY REFLECTANCE 0.200 |
| ||||||||
RC |
| 80 |
|
| 50 |
|
| 30 |
|
RW | 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 |
01 | 88 | 83 | 79 | 78 | 74 | 71 | 74 | 71 | 69 |
02 | 79 | 71 | 65 | 67 | 61 | 57 | 64 | 59 | 55 |
03 | 72 | 62 | 54 | 58 | 52 | 47 | 56 | 50 | 46 |
04 | 66 | 54 | 46 | 51 | 44 | 39 | 49 | 43 | 39 |
05 | 60 | 48 | 40 | 46 | 39 | 34 | 44 | 38 | 33 |
06 | 55 | 43 | 35 | 41 | 34 | 29 | 40 | 34 | 29 |
07 | 51 | 39 | 31 | 37 | 31 | 26 | 36 | 30 | 25 |
08 | 48 | 36 | 28 | 34 | 28 | 23 | 33 | 27 | 23 |
09 | 45 | 33 | 26 | 31 | 25 | 21 | 30 | 25 | 20 |
10 | 42 | 30 | 23 | 29 | 23 | 19 | 28 | 22 | 18 |
CANDELA DISTRIBUTION
| 0.0 | 45.0 | 90.0 | FLUX |
0 | 1053 | 1053 | 1053 |
|
5 | 1046 | 1047 | 1051 | 100 |
15 | 997 | 1015 | 1033 | 287 |
25 | 906 | 955 | 996 | 440 |
35 | 781 | 868 | 937 | 541 |
45 | 626 | 760 | 864 | 581 |
55 | 452 | 641 | 777 | 562 |
65 | 272 | 516 | 677 | 492 |
75 | 121 | 392 | 568 | 391 |
85 | 26 | 282 | 469 | 284 |
90 | 5 | 179 | 338 |
|
|
|
|
|
|
ZONAL LUMEN SUMMARY
ZONE | LUMENS | % LAMP | % FIXT |
827 | 18.8 | 22.5 | |
1368 | 31.1 | 37.2 | |
2511 | 57.1 | 68.3 | |
3678 | 83.6 | 100.0 | |
0000 | 0.0 | 000.0 | |
3678 | 83.6 | 100.0 |
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. | |||
45 | 1187. | 1407. | 1562. |
55 | 1036. | 1421. | 1667. |
65 | 820. | 1482. | 1856. |
75 | 558. | 1670. | 2251. |
85 | 271. | 2473. | 3547. |
Model No. HDS2GLW254UNVPG
LER = FP - 71.5 IW - 93.9 BF - 1.02 Comparative yearly lighting energy cost per
1000 lumens = $3.36
Report Number: G2008216
Catalog Number: HDS2GLW254UNVPG
Lamps: (2) F54 T5 HO
Luminaire: HP90
Ballast:
Report is based on 4400 Lumens per lamp. Efficiency: 74.8%
CIE |
|
|
|
| |||||
Plane: |
|
|
|
|
| ||||
Spacing Criteria: |
|
| 1.2 |
|
| 1.4 | |||
Shielding Angles: |
|
| 90 |
|
| 90 | |||
Plane: |
|
|
|
|
| ||||
Luminous Length: |
| 47.880 |
| 23.040 | |||||
COEFFICIENTS OF UTILIZATION – |
|
| |||||||
ZONAL CAVITY METHOD. EFFECTIVE |
| ||||||||
FLOOR CAVITY REFLECTANCE 0.200 |
| ||||||||
RC |
| 80 |
|
| 50 |
|
| 30 |
|
RW | 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 |
01 | 79 | 75 | 71 | 70 | 67 | 64 | 67 | 64 | 62 |
02 | 71 | 64 | 58 | 60 | 55 | 51 | 57 | 53 | 50 |
03 | 64 | 56 | 49 | 52 | 46 | 42 | 50 | 45 | 41 |
04 | 59 | 49 | 42 | 46 | 40 | 35 | 44 | 39 | 35 |
05 | 54 | 43 | 36 | 41 | 35 | 30 | 39 | 34 | 30 |
06 | 50 | 39 | 32 | 37 | 31 | 26 | 36 | 30 | 26 |
07 | 46 | 35 | 28 | 33 | 27 | 23 | 32 | 27 | 23 |
08 | 43 | 32 | 25 | 31 | 25 | 21 | 30 | 24 | 20 |
09 | 40 | 29 | 23 | 28 | 22 | 18 | 27 | 22 | 18 |
10 | 37 | 27 | 21 | 26 | 20 | 17 | 25 | 20 | 17 |
CANDELA DISTRIBUTION0
| 0.0 | 45.0 | 90.0 | FLUX |
0 | 1891 | 1891 | 1891 |
|
5 | 1879 | 1881 | 1888 | 179 |
15 | 1794 | 1825 | 1852 | 516 |
25 | 1635 | 1713 | 1779 | 789 |
35 | 1410 | 1556 | 1679 | 972 |
45 | 1135 | 1367 | 1553 | 1047 |
55 | 822 | 1155 | 1397 | 1014 |
65 | 502 | 928 | 1204 | 885 |
75 | 230 | 699 | 992 | 695 |
85 | 50 | 494 | 782 | 486 |
90 | 9 | 302 | 547 |
|
ZONAL LUMEN SUMMARY
ZONE | LUMENS | % LAMP | % FIXT |
1484 | 16.9 | 22.5 | |
2456 | 27.9 | 37.3 | |
4517 | 51.3 | 68.6 | |
6583 | 74.8 | 100.0 | |
0000 | 00.0 | 000.0 | |
6583 | 74.8 | 100.0 |
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE IN DEG.
45 2152. 2530. 2807.
55 1885. 2560. 2997.
65 1514. 2665. 3301.
75 1060. 2979. 3931.
85 522. 4332. 5914.
Ordering Information
Explanation of Catalog Number. Example: HDS2GLW254UNVPG
| HD |
| S |
| 2 |
| G |
| L | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| HP90 | Body Style: |
| Fixture | Ceiling | Type: | Acrylic Lens | |||||||
Direct/Indirect | S = Static |
| Width |
| Fits both |
|
| |||||||
|
|
|
|
|
| Standard Grid |
|
| ||||||
|
|
|
|
|
|
|
|
|
| and |
|
| ||
|
|
|
|
|
|
|
|
|
| Slot Grid |
|
|
W
Reflector:
White
|
|
| 54 |
| UNV |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Lamp | Lamp: | Voltage: |
|
|
| Options: | |||||||||
Quantity | (By Others) |
|
|
| Add appropriate | ||||||||||
1=1 Lamp | 54=T5 54W |
|
|
|
|
|
| suffix to catalog | |||||||
2=2 Lamp | (Nominal 48") |
|
|
|
|
|
|
| no., ie: (A) | ||||||
|
|
|
|
|
|
|
|
| Ballast Type: |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| <20THD <10THD | ||||
|
|
|
|
|
| 1 Lamp Elec. T5 HO | – |
| PG †† | ||||||
|
|
|
|
|
|
| (54 Watt) |
|
| PG †† | |||||
|
|
|
|
|
| 2 Lamp Elec. T5 HO | – |
| |||||||
|
|
|
|
|
|
| (54 Watt) |
|
|
|
|
| |||
|
|
|
|
|
| ††Program Rapid Start (UNV only) |
|
|
|
|
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: A.
Internal slow blow fusing: SUFFIX: C.
Drywall Kit: Order Catalog Number: FK92X4.
Electrical Wiring Options: Consult factory.
For motion or light sensor: See Folio
Specifications
Performance: In an installation of 2 lamp 54W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .75. To reduce glare the average brightness at 65° shall not exceed 3301 candelas per square meter. To control veiling reflections, luminaire output in the
Materials: Chassis parts are
Lamp Shield: Linear prismatic translucent DR acrylic lens.
Finish: Chassis exterior – Soft white post painted polyester powder. Cavity – Soft white post painted polyester powder. Rust preventative undercoating. Reflector – Soft white post painted polyester powder.
Lightolier is a Philips group brand
Specifications (continued)
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.
UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Job Information Type:
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508)
www.lightolier.com © 2008 a Philips Group | Section 5/Folio |