HP90 Semi HDS2GLW1FT

Page 2 of 2

Direct/Indirect Semi-Recessed Fluorescent 2' x 2' with Acrylic Linear Prismatic Lens, 1 Lamp TT5

Model No. HDS2GLW1FTUNVPR

LER = FP - 64.1 IW - 38.4 BF - 1.0 Comparative yearly lighting energy cost per

1000 lumens = $3.74

Report Number: G2008239

Catalog Number: HDS2GLW1FTUNVPR

Lamps: (1) F40 TT5

Luminaire: HP90 Semi-Recssed 2' x 2' with

linear prismatic lens.

Ballast: ICN-2TTP40-SC

Report is based on 3150 Lumens per lamp. Efficiency: 78.2%

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.2

 

 

1.4

Shielding Angles:

 

 

90

 

 

90

Plane:

 

 

 

 

0-Deg

 

90-Deg

Luminous Length:

 

23.040

 

23.040

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.200

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

01

83

78

74

73

70

67

70

67

65

02

75

67

61

63

58

54

60

56

53

03

68

59

52

55

49

45

53

48

44

04

62

52

44

49

42

38

47

41

37

05

57

46

39

43

37

32

42

36

32

06

52

41

34

39

33

28

38

32

28

07

49

37

30

36

29

25

34

29

25

08

45

34

27

32

26

22

31

26

22

09

42

31

25

30

24

20

29

24

20

10

40

29

22

28

22

18

27

22

18

CANDELA DISTRIBUTION

 

0.0

45.0

90.0

FLUX

0

737

737

737

 

5

731

734

736

70

15

699

712

722

201

25

640

669

694

308

35

556

604

646

377

45

449

519

582

399

55

321

425

511

376

65

183

333

428

317

75

81

246

341

242

85

17

174

277

172

90

3

115

208

 

 

 

 

 

 

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

00-030

579

18.4

23.5

00-040

957

30.4

38.8

00-060

1723

55.0

70.3

00-090

2463

78.2

100.0

90-180

0000

0.0

000.0

00-180

2463

78.2

100.0

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG. 45-DEG. 90-DEG.

45

1687.

1949.

2186.

55

1431.

1895.

2278.

65

1043.

1897.

2439.

75

667.

2026.

2808.

85

267.

2735.

4353.

Ordering Information

Explanation of Catalog Number. Example: HDS2GLW1FTUNVPR

HD

S

2

G

L

W

1

FT

HP90

Body Style:

Fixture

Ceiling Type:

Acrylic Lens

Reflector:

Direct/Indirect

S = Static

Width

Fits both

 

White

Semi-Recessed

 

 

Standard Grid

 

 

 

 

 

and

 

 

 

 

 

Slot Grid

 

 

Options/Accessories

Fusing: Internal fast blow fusing: SUFFIX: A. Internal slow blow fusing: SUFFIX: C.

Drywall Kit: Order Catalog Number: FK92X2.

Electrical Wiring Options: Emergency Packs are only avalable for remote mounting. Consult factory.

LampLamp:

Quantity (By Others) 1=1 Lamp

Voltage:

 

 

 

 

 

 

 

 

Options:

120, 277 or

 

 

 

Add appropriate

UNV=120-277

 

 

 

suffix to catalog

 

 

 

 

no., ie: (A)

 

Ballast

Type:

 

 

 

 

<20THD <10THD

1 Lamp Elec. TT5

 

SB*

IB**

(40 Watt)

 

PR†

1 Lamp Elec. TT5

 

(40 Watt)

 

BE*

 

 

1 Lamp Elec. TT5

 

(50 Watt)

 

BF*

1 Lamp Elec. TT5

 

(55 Watt)

 

PB

LOL Dimming TT5

 

*Instant Start Standard.

Other dimming options. Consult factory.

NOTE:

For TT5 40W UNV, you must use IB or PR Ballast Code. †Program Rapid Start

For motion or light sensor: See Folio OA20-10.

Specifications

Performance: In an installation of 1 lamp 40W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .78. To reduce glare the average brightness at 65° shall not exceed 2439 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 76.5%.

Materials: Chassis parts are die-formed code gauge steel.

Lamp Shield: Linear prismatic translucent DR acrylic lens.

Finish: Chassis exterior – Soft white post painted polyester powder. Cavity – Soft white post painted polyester powder. Rust preventative undercoating. Reflector – Soft white post painted polyester powder.

Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed.

This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org

Job Information Type:

For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

www.lightolier.com © 2008 a Philips Group

Section 5/Folio M33-30

Lightolier is a Philips group brand

Page 2
Image 2
Lightolier HDS2GLW1FT dimensions Ordering Information, Options/Accessories, Specifications

HDS2GLW1FT specifications

The Lightolier HDS2GLW1FT represents a significant advancement in the realm of industrial and commercial lighting solutions. This innovative fixture is designed to meet the demands for high performance in energy efficiency while providing aesthetic versatility for a variety of settings.

One of the standout features of the HDS2GLW1FT is its exceptional lumen output, delivering bright illumination that can enhance visibility and safety in large areas such as warehouses, retail spaces, and office environments. It boasts an impressive lumen efficacy, which ensures that it utilizes energy efficiently while providing maximum brightness. This feature is particularly beneficial for businesses looking to minimize operational costs without sacrificing quality of light.

The HDS2GLW1FT is equipped with advanced LED technology, which not only contributes to its energy efficiency but also offers a longer lifespan compared to traditional lighting solutions. This results in reduced maintenance costs and the need for less frequent replacements, further supporting the bottom line for organizations. The fixture features a robust construction that is both durable and reliable, capable of withstanding various environmental conditions.

Another key characteristic of the HDS2GLW1FT is its design flexibility. It comes with adjustable mounting options, allowing for seamless integration into different architectural settings. Whether hung from ceilings or mounted on walls, the fixture adapts to the specific needs of the space, making it a versatile choice for designers and facility managers alike.

In addition to its performance and adaptability, the HDS2GLW1FT includes advanced control options, further enhancing its functionality. Compatible with various dimming systems and smart building technologies, this fixture can be easily integrated into existing lighting systems. This capability facilitates energy management and helps users achieve their sustainability goals by optimizing energy use.

Overall, the Lightolier HDS2GLW1FT stands out as an exemplary lighting solution characterized by its efficiency, longevity, and adaptability. Its combination of cutting-edge technology and thoughtful design makes it an excellent choice for a wide range of applications, ensuring that spaces are well-lit, functional, and visually appealing. For any organization committed to enhancing their lighting infrastructure while leveraging modern advancements, the HDS2GLW1FT is undoubtedly worth considering.