Lightolier manual Page 1 of, Lightolier is a Philips group brand, How to Specify IE, Features

Models: IE

1 2
Download 2 pages 7.01 Kb
Page 1
Image 1
IE Series Emergency Lighting  IE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IE Series Emergency Lighting  IE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 1 of 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6 Volt or 12 Volt, 28 to 180 Watts NEMA-Rated

The IE Series is ideal for locations where oil-water-and dust resistant equipment is required. The housing meets NEMA 3, 4x and 12 classifications.

25 Watt to 75 Watt Units

 

 

 

100 Watt to 180 Watt Units

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21.4”

 

 

 

 

 

 

 

19.4”

 

 

 

 

 

 

 

 

 

 

(49.4 cm)

 

 

 

 

 

 

 

(54.4 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21.4”

 

 

 

 

 

 

 

19.4”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(54.4 cm)

 

 

 

13.2”

 

 

 

 

 

 

15.2”

 

 

 

 

 

 

 

(49.2 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(33.6 cm)

 

 

 

 

 

 

 

(38.6 cm)

 

7.3”

6.8”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11.2”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13.2”

 

 

 

 

 

 

 

 

(18.7 cm)

 

(28.5 cm)

 

 

 

 

(17.3 cm)

 

(33.6 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Complete Fixture consists of unit and two lamp heads. Select options and accessories below.

How to Specify:

IE

SERIES

VOLTAGE

IE = NEMA-Rated

1

= 6V

Emergency Lighting Unit

2

= 12V

NOTES:

1)Includes temperature compensated charger.

2)Units come standard with AC input fuse.

3)Not available with SD, SA and SDTD options

 

 

 

BATTERY/DC VOLTAGE

# OF HEADS

6V, Lead Calcium

12V, Lead Calcium

12V, Nickel Cadmium

2

= Two

28L

= 28W Unit1

50L

= 50W Unit 1

25N

= 25W Unit

1

= One

50L

= 50W Unit

10L

= 100W Unit 1,2

50N

= 50W Unit

Blank = No Heads

75L

= 75W Unit

12L

= 125W Unit 1,2

10N

= 100W Unit

 

 

10L

= 100W Unit 1,2

15L

= 150W Unit 1,2

12N

= 125W Unit 2

 

 

6V, Nickel Cadmium

18L

= 180W Unit 1,2

15N

= 150W Unit

 

 

25N = 25W Unit

12V, Pure Lead

 

 

 

 

50N = 50W Unit

12P = 120W Unit 2

 

 

 

 

LAMP HEADS

6V, Tungsten

12V, Tungsten

IT8 = 8W

IT12 = 12W

IT18 = 18W

IT18 = 18W

IT25 = 25W

IT25 = 25W

IT30 = 30W

IT30 = 30W

6V, Halogen

12V, Halogen

IH6 = 6W

IH8 = 8W

IH8 = 8W

IH12 = 12W

IH12 = 12W

IH50 = 50W

Features

1.Illumination: Illumination is accomplished with lamp heads mounted on the top of the unit. The NEMA-rated lamp head is available in a variety of wattages, and is constructed of gray polycarbonate to match the IE Series housing.

2.Housing: Constructed of impact resistant, fiberglass reinforced polyester. Housing color is gray and includes stainless steel hardware. View-through window allows easy monitoring of AC indicator and optional voltmeter and ammeter.

3.Electronics: 120/277 VAC dual voltage input with surge-protected, solid- state circuitry. Select units include a temperature-compensated charger. Charging system is complete with low voltage disconnect, AC lockout, brownout protection, AC indicator lamp and test switch.

4.Battery: Maintenance free, sealed lead calcium battery has an estimated service life of 5 years, and an operating temperature range of 65°F (19°C) to 85°F (30°C). Maintenance free, sealed nickel cadmium battery has an esti- mated service life of 10 years, and an operating temperature range of 20°F (-7°C) to 95°F (35°C).

5.Input Power Requirements: 120 VAC - 0.42 amps, 50.4 watts; 277 VAC - 0.20 amps, 50.4 watts

Code Compliance

UL 924 listed.

NSF/ANSI Standard 2 Food Equipment optional

Options

SD = Self-Diagnostics

SA = Self-Diagnostics with Alarm

SDTD = Self-Diagnostics with Time Delay

V = Voltmeter 3

A = Ammeter 3

T1 = 120 VAC Time Delay (15 minute)

T2 = 277 VAC Time Delay (15 minute)

Lightolier is a Philips group brand

Options (continued)

LCK1 = Line Cord (6’, 120 VAC field installed)

F1 = 120 VAC Fuse

F2 = 277 VAC Fuse

P1 = 120 VAC Power Switch

P2 = 277 VAC Power Switch DC = DC Power Switch

ST = Special Input Transformer (specify voltage and frequency) HTR1 = 120 VAC Heater (Not UL listed)

HTR2 = 277 VAC Heater (Not UL listed)

S = Shatter Resistant Lamp Head Shield

Multiple option configurations may void UL listing. Consult factory for specifics.

Accessories

WG5 = Wire Guard (25-75w units)

WG = Wire Guard (100w units)

NSF = NSF/ANSI Standard 2 Food Equipment

Job Information

Type:

 

 

Job Name:

Cat. No.:

Lamp(s):

Notes:

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2008 Philips Group • E0308