READ AND UNDERSTAND THESE INSTRUCTIONS |
|
|
|
| |
INSTRUCTION SHEET NO. |
| ||||
BEFORE INSTALLING LUMINAIRE. |
|
|
|
|
|
| IS:1000LVR |
| |||
installation. To prevent electric shock, turn off electricity at main power supply before proceeding. |
|
| |||
This luminaire is intended for installation in accordance with the National Electrical Code and local regulations. |
|
|
|
|
|
To assure full compliance with local codes and regulations, check with your local electrical inspector before |
|
|
|
|
|
Retain these instructions for maintenance reference. |
|
|
|
|
|
|
|
|
|
| |
| B0607 |
| Page 1 of 1 |
|
INSTALLATION PROCEDURE FOR: LYTECASTER® 1000LVR & 1000LVRE1 LOW VOLTAGE REMODELER KIT
CAUTION: USE ONLY WITH REFLECTOR TRIMS PROVIDED BY LIGHTOLIER. USE OF OTHER MANUFACTURER’S TRIMS MAY VOID THE
UNDERWRITERS LABORATORIES LISTING AND COULD CONSTITUTE A FIRE HAZARD.
CAUTION: BEFORE INSTALLING
DETERMINE LAMP WATTAGE AND TYPE APPLICABLE FOR YOUR INSTALLATION.
WARNING: (RISK OF FIRE) DO NOT INSTALL INSULATION WITHIN 3” OF FIXTURE SIDES OR WIRING COMPARTMENT, NOR ABOVE
FIXTURE IN SUCH A MANNER SO AS TO ENTRAP HEAT.
1.CUT OPENING (Fig. A)
Use aperture sticker provided as a template to cut a hole in the ceiling. Cut to outside edge of sticker.
*Lightolier also offers a hole cutter
Figure A
2. WIRE IN & PUSH THRU
Figure B
Wire to SUPPLY LEADS. (For Cable, use built in CABLE CLAMP in
HOT SUPPLY LEAD (120V). BARE FIXTURE LEAD WIRE TO SUPPLY GROUND. Use wirenuts (local hardware item). Place all electrical connections in
Figure C
3.ATTACH MOUNTING RING (Fig. D)
Push MOUNTING RING into opening until FLANGE sits against ceiling. Slide MOUNTING STRAPS down to trap ceiling thickness and then bend up to secure (Fig. E). Make sure
Figure DFigure E
4. ATTACH
Insert
Figure F |
|
|
| Figure G | ||
|
|
|
| |||
|
|
|
|
|
|
|
| 5. | SEE SEPARATE |
| |||
|
| → | REFLECTOR TRIM |
| ||
|
| INSTRUCTION |
| |||
| 6. | SHEETS |
| |||
|
|
|
|
| ||
Figure H |
|
| Figure I | |||
|
|
|
| A |
| COMPANY |
|
|
|
| |||
|
|
|
|