Lightolier L1, LC installation instructions Lightolier

Models: LC

1 1
Download 1 pages 5.74 Kb
Page 1
Image 1
Lightolier

Lightolier

45 INDUSTRIAL WAY, WILMINGTON, MA 01887

INSTALLATION INSTRUCTIONS FOR LYTECEL (Both LI and LC)

1 ACCESS PLATE

Remove Access Plate by sliding Access Plate in the direction of Arrow 1. To remove, lift up and slide in the direction of Arrow 2. Bend Fixture Tab up out of body and make ground and ballast connections. Bend Fixture Tab back to original position. Replace Access Plate by reversing removal instructions.

 

1.

Access

Ground

 

Plate

Access

Screw

 

 

Access

Plate

 

 

 

Opening

 

 

Plate

Fixture

 

 

 

Opening

 

 

 

Tab

2.

 

 

 

 

 

 

 

Tab

Access

 

 

 

Plate

 

 

 

 

 

 

 

 

Opening

 

 

 

2 INSTALL FIXTURES onto T-bars as shown.

T-bar

Fixture

3

CONTINUOUS ROW COUPLER (LC UNITS

 

ONLY) Remove screw as shown. Rotate

Continuous Row Coupler (both sides of

Fixtures) and secure Fixtures together with Screw. Tighten all Screws to secure Fixtures to T-bar with Hold-down Clips.

Fixtures

Fixtures

Continuous

 

Row Coupler

 

 

Hold-

Screw

down Clip

 

Hold-

Continuous

down Clip

Row Coupler

T-bar

Screw

 

 

T-bar

HOLD-DOWN CLIPS (LI UNITS ONLY)

4 Install Hold-down Clips at beginning and end of rows.

Fixtures

Hold- down Clip

5

To open Louver,

 

 

press Spring Latch

Fixtures

Spring

 

in direction of

 

 

 

Arrow. To close,

 

Latch

 

 

 

insert louver into Fixture until Spring Latches automatically engage.

Screw

© Lightolier 2003

59-31123-000

Printed in U.S.A.