Lightolier LIA6GPNXR254 Ordering Information, Options/Accessories, Specifications continued

Models: LIA6GPNXR154 LIA6GPNXR254

1 2
Download 2 pages 15.05 Kb
Page 2
Image 2
Page 2 of 2

Lytecel 6 LIA6GPNXR154 or 254

Page 2 of 2

Model No. LIA6GPNXR154UNVPG

Recessed Lens Fluorescent, Static or Air Return 6" Width X 48" Length, 1 or 2 Lamp T5HO

Model No. LIA6GPNXR254UNVPG

LER = FP - 51.3 IW - 54.79 BF - 1.0 Comparative yearly lighting energy cost per

1000 lumens = $4.68 Report Number: G2008043

Catalog Number: LIA6GPNXR154UNVPG

Lamp: (1) F54 T5HO

Luminaire: 6" wide Troffer with PN lens.

Ballast: B254PUNV-D

Report is based on 4400 Lumens per lamp. Efficiency: 63.9%

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.2

 

 

1.1

Shielding Angles:

 

 

90

 

 

90

Plane:

 

 

 

 

0-Deg

 

90-Deg

Luminous Length:

 

46.800

 

4.560

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.200

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

1

70

67

65

63

61

60

61

59

58

2

64

59

55

56

53

50

54

51

49

3

59

52

48

50

46

43

48

45

42

4

54

47

41

44

40

37

43

39

36

5

50

42

37

40

35

32

39

35

32

6

46

38

32

36

32

28

35

31

28

7

43

35

29

33

28

25

32

28

25

8

40

32

26

30

26

23

30

25

22

9

37

29

24

28

24

20

27

23

20

10

35

27

22

26

22

19

25

21

18

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG. 45-DEG. 90-DEG.

45

7886.

6849.

6325.

55

7557.

6051.

5190.

65

6941.

4707.

3505.

75

5554.

2497.

2609.

85

2582.

2499.

2083.

CANDELA DISTRIBUTION

 

0.0

45.0

90.0

FLUX

0

1186

1186

1186

 

5

1166

1176

1182

112

15

1119

1111

1000

313

25

1034

988

951

457

35

914

827

799

529

45

768

667

616

522

55

597

478

410

433

65

404

274

204

283

75

198

89

93

129

85

31

30

25

33

90

3

9

12

 

 

 

ZONAL LUMEN SUMMARY

 

 

 

 

ZONE

LUMENS % LAMP

% FIXT

00-030

882

 

20.0

31.4

00-040

1410

 

32.1

50.2

00-060

2366

 

53.8

84.2

00-090

2811

 

63.9

100.0

90-180

0000

 

0.0

000.0

00-180

2811

 

63.9

100.0

LER = FP - 44.7 IW - 93.9 BF - 1.00 Comparative yearly lighting energy cost per

1000 lumens = $5.37 Report Number: G2008058

Catalog Number: LIA6GPNXR254UNVPG

Lamp: (2) F54 T5HO

Luminaire: 6" wide Troffer with PN lens.

Ballast: B254PUNV-D

Report is based on 4400 Lumens per lamp. Efficiency: 47.7%

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.2

 

 

1.1

Shielding Angles:

 

 

90

 

 

90

Plane:

 

 

 

 

0-Deg

 

90-Deg

Luminous Length:

 

46.800

 

4.560

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.200

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

1

52

50

48

47

45

44

45

44

43

2

48

44

41

42

39

37

40

38

36

3

44

39

36

37

34

32

36

33

31

4

40

35

31

33

30

27

32

29

27

5

37

31

27

30

26

24

29

27

24

6

34

28

24

27

24

21

26

23

21

7

32

26

22

25

21

19

24

21

19

8

30

24

20

23

19

17

22

19

17

9

28

22

18

21

18

15

20

17

15

10

26

20

16

19

16

14

19

16

14

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG. 45-DEG. 90-DEG.

45

11767.

10247.

9508.

55

11253.

9101.

7759.

65

10273.

7009.

5188.

75

8191.

3899.

3927.

85

3582.

3749.

3166.

CANDELA DISTRIBUTION

 

0.0

45.0

90.0

FLUX

0

1767

1767

1767

 

5

1741

1753

1760

167

15

1672

1655

1635

467

25

1545

1472

1415

681

35

1367

1233

1195

789

45

1146

998

926

781

55

889

719

613

649

65

598

408

302

422

75

292

139

140

192

85

43

45

38

49

90

6

14

18

 

 

 

ZONAL LUMEN SUMMARY

 

 

 

 

ZONE

LUMENS % LAMP

% FIXT

00-030

1314

 

14.9

31.3

00-040

2104

 

23.9

50.1

00-060

3534

 

40.2

84.2

00-090

4197

 

47.7

100.0

90-180

0000

 

0.0

000.0

00-180

4197

 

53.0

100.0

Ordering Information

Explanation of Catalog Number. Example: LIA6GPNXR154UNVPG

6

 

 

 

 

 

 

 

 

Lytecel

Body Style:

Fixture

Ceiling Type:

 

Lens

Style:

 

A =Air Return

Width 6"

G = 9/16" or

PN = .08 White

 

S =Static

 

15/16"Grid

 

Acyrlic

 

 

 

T = Slot Grid

VA = .095 Virgin

X

R

Lamp

Quantity:

(By others)

1=1 Lamp

54

Lamp Fixture

Length: 54=T5HO (Nominal 48")

 

 

 

-

 

 

 

UNV

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage:

 

 

Options:

 

Add appropriate

120, 277 or

 

 

suffix to catalog

UNV=120-277

 

 

 

no, ie: (A)

 

 

 

 

 

D = 9/16" Tegular

Acyrlic

Grid

 

Reflector:

2=2 Lamps

LI

Standard Lytecel

KA = .156 Virgin

Acyrlic

 

 

 

 

LN

For NYC Code – Local 3 Manufactured

 

 

 

Options/Accessories

Access Plate: Top Wiring access plate is shipped with fixture as standard. When access plates are required in advance for wiring convenience, specify separately. Order Catalog Number: ACP5 CSP.

Electrical/Wiring Options: Consult factory.EM Pack or Dimming Ballast: Consult factory.

Fusing: Internal fast-blow fusing. Suffix: A.

Internal slow-blow fusing. Suffix: C.

Chicago Plenum: Suffix: P.

W=Miro aluminum

Reflector

Ballast Type:

<10THD

1 or 2 Lamp 54w Elec. T5

PG

Program Rapid Start (UNV Only)

DA=DALI digital addressable dimming.

Specifications (continued)

Finish: Reflector: 95% reflective Miro aluminum reflector. Chassis exterior—black baked polyester enamel.

Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

Labels: I.B.E.W./UL and ULc Listed.

This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org

Specifications

Performance: In an installation of 1 lamp 54W luminaire in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .67 with a spacing to mounting ratio of 1.1 perpendicular to the lamps. Air Handling- Side air slots for air return.

Materials: Chassis parts are 20 gauge cold rolled steel.

Lightolier is a Philips group brand

Job Information Type:

For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

www.lightolier.com © 2008 a Philips Group

Section 1A/Folio E10-20

Page 2
Image 2
Lightolier LIA6GPNXR254 Ordering Information, Options/Accessories, Specifications continued, Page 2 of, A/Folio E10-20

FAQ

What are the dimensions of the LIA6GPNXR154 and LIA6GPNXR254 models?

The LIA6GPNXR154 and LIA6GPNXR254 models have a width of 6" and a length of 48".

What type of ballast is used in the LIA6GPNXR154 and LIA6GPNXR254 models?

The LIA6GPNXR154 model uses a 1 Lamp 54w Electronic T5 ballast, while the LIA6GPNXR254 model uses a 2 Lamp 54w Electronic T5 ballast.

Are the LIA6GPNXR154 and LIA6GPNXR254 models suitable for dimming?

Yes, the LIA6GPNXR154 and LIA6GPNXR254 models can be equipped with a DALI digital addressable dimming option.