Lytecel Recessed Fluorescent LIS6G20LW154

Page 2 of 2

6" wide x 48", 20 Cell (1 Row) Parabolic Louver, Air Return/Static, 1 Lamp T5, IES RP1 For VDT Areas

Model No. LIS6G20LW154120PG

LER = FP - 40.3 IW - 59.0 BF - 1.0 Comparative yearly lighting energy cost per

1000 lumens = $5.95 Report Number: G1206004

Catalog Number: LIS6G20LW154120PG

Lamp: F54 T5HO

Luminaire: 6" wide Troffer with semi- specular louver and white reflector. Ballast: Advance ICN-2S54

Report is based on 4400 Lumens per lamp. Efficiency: 54.9%

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.2

 

 

1.6

Shielding Angles:

 

 

90

 

 

90

Plane:

 

 

 

 

0-Deg

 

90-Deg

Luminous Length:

 

47.943

 

5.816

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.20

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

1

61

60

58

56

55

54

54

53

52

2

57

54

51

51

49

47

49

48

46

3

53

49

45

47

44

42

45

43

41

4

50

44

40

42

39

37

41

38

36

5

46

40

36

39

35

33

38

35

32

6

43

37

32

35

32

29

34

31

29

7

40

33

29

32

29

26

32

28

26

8

37

31

27

30

26

24

29

26

23

9

35

28

24

27

24

21

27

24

21

10

33

26

22

25

22

19

25

22

19

 

 

 

 

 

 

 

 

 

 

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG. 45-DEG. 90-DEG.

45

4954.

6726.

3485.

55

3605.

2128.

1068.

65

264.

401.

278.

75

63.

84.

135.

85

41.

69.

124.

CANDELA DISTRIBUTION

 

0.0

 

45.0

90.0

FLUX

0

1040

 

1040

1040

 

 

5

1059

 

1075

1113

102

15

978

 

1069

1124

302

25

900

 

1081

1412

514

35

792

 

1193

1432

711

45

630

 

856

443

523

55

372

 

220

110

227

65

20

 

30

21

29

75

3

 

 

4

 

6

 

5

85

1

 

 

1

 

2

 

2

90

0

 

 

1

 

1

 

 

 

 

 

 

 

 

 

 

TYPICAL V.C.P.'s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mounting Height

 

 

 

Lengthwise Crosswise

Room

Luminaires

Luminaires

Size

0 Deg Plane

90 Deg Plane

 

8.5

10

8.5

10

8.5

10

8.5

10

30x30

89

85

84

76

96

93

92

84

40x40

89

86

85

81

96

93

93

87

60x30

80

86

85

79

96

93

92

85

60x60

89

86

84

81

96

94

93

88

100x100

89

86

84

82

96

95

94

88

 

 

 

 

ZONAL LUMEN SUMMARY

 

 

 

 

 

 

 

ZONE

LUMENS

% LAMP

% FIXT

00-030

918

 

 

20.9

 

38.0

00-040

1629

 

 

37.0

 

67.5

00-060

2379

 

 

54.1

 

98.5

00-090

2414

 

 

54.9

 

100.0

90-180

0000

 

 

0.0

 

000.0

00-180

2414

 

 

54.9

 

100.0

Model No. LIS6G20PW154120PG

LER = FP - 43.4 IW - 59.0 BF - 1.0 Comparative yearly lighting energy cost per

1000 lumens = $5.53 Report Number: G1206005

Catalog Number: LIS6G20PW154120PG

Lamps: F54 T5HO

Luminaire: 6" wide Troffer with specular louver and white reflector.

Ballast: Advance ICN-2S54

Report is based on 4400 Lumens per lamp.

Efficiency: 58.2%

 

 

 

 

 

 

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.2

 

 

1.6

Shielding Angles:

 

 

90

 

 

90

Plane:

 

 

 

 

0-Deg

 

90-Deg

Luminous Length:

 

47.943

 

5.816

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.20

 

 

 

 

 

 

 

 

 

 

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

1

65

63

61

60

58

57

57

56

55

2

61

57

54

54

52

50

52

51

49

3

57

52

48

49

46

44

48

45

43

4

53

47

43

45

41

39

44

41

38

5

49

43

38

41

37

34

40

37

34

6

45

39

34

37

34

31

36

33

30

7

42

35

31

34

30

28

33

30

27

8

39

32

28

31

28

25

31

27

25

9

37

30

25

29

25

22

28

25

22

10

35

28

23

27

23

20

26

23

20

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG. 45-DEG. 90-DEG.

45

5251.

7583.

3387.

55

4318.

2106.

923.

65

10.

397.

242.

75

14.

75.

159.

85

45.

103.

192.

CANDELA DISTRIBUTION

 

0.0

 

45.0

90.0

FLUX

0

1052

 

1052

1052

 

 

5

1082

 

1101

1094

103

15

1029

 

1102

1130

306

25

927

 

1090

1491

532

35

829

 

1350

1617

782

45

668

 

965

431

568

55

446

 

217

95

244

65

1

 

30

18

20

75

1

 

 

3

 

7

 

4

85

1

 

 

2

 

3

 

2

90

0

 

 

1

 

1

 

 

 

 

 

 

 

 

 

 

TYPICAL V.C.P.'s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mounting Height

 

 

 

Lengthwise Crosswise

Room

Luminaires

Luminaires

Size

0 Deg Plane

90 Deg Plane

 

8.5

10

8.5

10

8.5

10

8.5

10

30x30

87

76

78

75

96

93

93

84

40x40

87

76

78

79

97

93

93

87

60x30

87

76

78

79

96

93

93

85

60x60

88

77

79

79

96

94

94

88

100x100

88

77

79

79

95

94

95

89

 

 

 

 

ZONAL LUMEN SUMMARY

 

 

 

 

 

 

 

ZONE

LUMENS

% LAMP

% FIXT

00-030

 

942

 

 

21.4

 

36.8

00-040

1724

 

 

39.2

 

67.3

00-060

2536

 

 

57.6

 

99.0

00-090

2563

 

 

58.2

 

100.0

90-180

0000

 

 

0.0

 

000.0

00-180

2942

 

 

51.6

 

100.0

Ordering Information

Explanation of Catalog Number. Example: LIS6G20LW154120PG

6

20

W

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LI:

Body Style:

Fixture

Ceiling Type:

Number of

Louver Finish:

 

 

 

Lamp

 

Lamp Fixture

Voltage:

 

 

Options:

 

 

Lytecel 6"

A =Air Return

Width

G = 9/16" or

Cells:

L=Low

 

 

 

Quantity:

 

Length:

 

Add appropriate

 

 

 

 

 

 

120, 277 or

 

 

 

 

S =Static

 

15/16"Grid

1 row of

Iridescence

 

 

 

(By others)

 

28=T5

 

suffix to catalog

 

 

 

 

 

 

 

 

UNV=120-277

 

 

 

 

 

 

T = Slot Grid

20 cells

Semi-specular

 

 

 

1=1 Lamp

 

54=T5HO

 

no, ie: (GLR)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A = 9/16" Tegular

 

 

P=Low

 

 

 

 

 

 

(Nominal 48")

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LI

Standard Lytecel

 

 

Grid

 

 

Iridescence

 

 

 

 

 

 

 

Ballast

Type:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D = 15/16" Tegular

 

 

Specular

 

 

 

 

 

 

 

 

 

<20THD

<10THD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LN

For NYC Code – Local 3 Manufactured

 

Grid

 

 

 

 

Reflector:

 

 

1 Lamp 28w Elec. T5

PI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W=White Reflector

 

 

1 Lamp 28w Elec. T5

PG††

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 Lamp 54w Elec. T5

PG††

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

†Instant Start (120, 277 or UNV)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

††Program Rapid Start (UNV only)

Options/Accessories

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DA=DALI digital addressable dimming

 

 

 

 

 

 

 

Specifications (continued)

 

 

 

Access Plate: Top Wiring access plate is shipped with fixture as standard. When

 

 

 

access plates are required in advance for wiring convenience, specify separately.

Finish: Louver—specular or semi-specular low iridescence pre-anodized

Order Catalog Number: ACP5 CSP.

 

 

 

 

 

 

 

reflector sheet. Reflector: White baked polyester enamel reflector. Chassis

Electrical/Wiring Options: Consult factory.

 

 

 

 

 

 

exterior—black baked polyester enamel.

 

 

 

EM Pack or Dimming Ballast: Consult factory.

 

 

 

 

 

 

Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If

Fusing: Internal fast-blow fusing. Suffix: GLR.

 

 

 

 

 

 

K.O. is within 3" of ballast, use wire suitable for at least 90°.

 

 

Internal slow-blow fusing. Suffix: GMF.

 

 

 

 

 

 

Labels: I.B.E.W./UL and ULc Listed.

 

 

 

Chicago Plenum: Suffix: CP.

 

 

 

 

 

 

 

This product may have a mercury containing lamp. Manage in accord with

 

 

 

 

 

 

 

 

 

 

 

Disposal Laws. See: www.lamprecycle.org

 

 

 

Specifications

Performance: In an installation of 1 lamp 54W semi-specular luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .60 with a spacing to mounting ratio of 1.6 perpendicular to the lamps. To meet IES RP-1 for VDT areas the VCP (visual comfort probability) shall not be less than 89 either crosswise or lengthwise and the candela value between 55° and 90° in the 0° to 90° planes shall not exceed 3605. Candelas at Nadir (0°) not to exceed 1040.

Air Handling-(LIA) side air passages for air return. Materials: Chassis parts are die-formed cold rolled steel. Louver: Pre-anodized aluminum (Coilzak® or equal).

 

Job Information

Type:

 

 

 

Lightolier a Genlyte company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2006 a Genlyte company

Section 2/Folio G07-38