Lytecel Linear LL4MF8LR232
Page 2 of 2
Model No. LL4MF8LR232120SO (8 Cell)
Downlight, Surface/Pendant,
Model No. LL4MF12LR232120SO (12 Cell)
LER = FP - 55.6 IW - 58 | BF - 0.87 |
Comparative yearly lighting energy cost per 1000 lumens = $4.32
Report Number: G2005007
Catalog Number: LL4MF8LR232120SO
Lamp: FP32/T8 TL841
Luminaire: LL4 with reflector, 8 cell louver
Ballast: Triad
Report is based on 2850 Lumens per lamp. Efficiency: 65.4%
CIE |
|
|
|
| |||||
Plane: |
|
|
|
|
| ||||
Spacing Criteria: |
|
| 1.2 |
|
| 1.5 | |||
Shielding Angles: |
|
| 65 |
|
| 55 | |||
Plane: |
|
|
|
|
| ||||
Luminous Length: |
| 48.000 |
| 6.480 | |||||
COEFFICIENTS OF UTILIZATION – |
|
| |||||||
ZONAL CAVITY METHOD. EFFECTIVE |
| ||||||||
FLOOR CAVITY REFLECTANCE 0.200 |
| ||||||||
RC |
| 80 |
|
| 50 |
|
| 30 |
|
RW | 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 |
01 | 73 | 70 | 68 | 66 | 65 | 63 | 64 | 63 | 61 |
02 | 68 | 63 | 60 | 60 | 57 | 55 | 58 | 56 | 54 |
03 | 63 | 57 | 52 | 54 | 51 | 48 | 52 | 49 | 47 |
04 | 58 | 51 | 46 | 49 | 45 | 42 | 47 | 44 | 41 |
05 | 53 | 46 | 41 | 44 | 40 | 37 | 43 | 39 | 36 |
06 | 50 | 42 | 37 | 40 | 36 | 32 | 39 | 35 | 32 |
07 | 46 | 38 | 33 | 36 | 32 | 29 | 36 | 32 | 29 |
08 | 43 | 35 | 30 | 33 | 29 | 26 | 33 | 29 | 26 |
09 | 40 | 32 | 27 | 31 | 26 | 23 | 30 | 26 | 23 |
10 | 37 | 29 | 24 | 28 | 24 | 21 | 28 | 24 | 21 |
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. | |||
45 | 6185. | 9067. | 9032. |
55 | 4004. | 5280. | 4264. |
65 | 802. | 1049. | 849. |
75 | 366. | 269. | 250. |
85 | 286. | 229. | 171. |
CANDELA DISTRIBUTION0
| 0.0 | 45.0 | 90.0 | FLUX |
0 | 1309 | 1309 | 1309 |
|
5 | 1325 | 1367 | 1387 | 132 |
15 | 1313 | 1485 | 1521 | 412 |
25 | 1257 | 1540 | 1695 | 704 |
35 | 1146 | 1590 | 1739 | 945 |
45 | 878 | 1287 | 1282 | 907 |
55 | 461 | 608 | 491 | 502 |
65 | 68 | 89 | 72 | 101 |
75 | 19 | 14 | 13 | 17 |
85 | 5 | 4 | 3 | 4 |
90 | 00 | 0 | 0 | 00 |
ZONAL LUMEN SUMMARY
ZONE | LUMENS | % LAMP | % FIXT |
1248 | 21.9 | 33.5 | |
2193 | 38.5 | 58.9 | |
3603 | 63.2 | 96.7 | |
3725 | 65.4 | 100.0 | |
00 | 00.0 | 000.0 | |
3725 | 65.4 | 100.0 |
LER = FP - 49.6 IW - 58 BF - 0.87 Comparative yearly lighting energy cost per
1000 lumens = $4.80
Report Number: G2005011
Catalog Number: LL4MF12LR232120SO
Lamp: F32/T8 TL841
Luminaire: LL4 with reflector, 12 cell louver
Ballast: Triad
Report is based on 2850 Lumens per lamp. Efficiency: 57.7%
CIE |
|
|
|
| |||||
Plane: |
|
|
|
|
| ||||
Spacing Criteria: |
|
| 1.2 |
|
| 1.5 | |||
Shielding Angles: |
|
| 65 |
|
| 55 | |||
Plane: |
|
|
|
|
| ||||
Lumen Length: |
|
| 48.000 |
| 6.480 | ||||
COEFFICIENTS OF UTILIZATION – |
|
| |||||||
ZONAL CAVITY METHOD. EFFECTIVE |
| ||||||||
FLOOR CAVITY REFLECTANCE 0.200 |
| ||||||||
RC |
| 80 |
|
| 50 |
|
| 30 |
|
RW | 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 |
01 | 65 | 63 | 61 | 59 | 58 | 56 | 57 | 56 | 55 |
02 | 60 | 57 | 54 | 54 | 51 | 49 | 52 | 50 | 48 |
03 | 56 | 51 | 47 | 49 | 46 | 43 | 47 | 45 | 43 |
04 | 52 | 46 | 42 | 44 | 41 | 38 | 43 | 40 | 38 |
05 | 48 | 42 | 37 | 40 | 37 | 32 | 39 | 36 | 33 |
06 | 46 | 38 | 34 | 37 | 33 | 30 | 36 | 32 | 30 |
07 | 42 | 35 | 30 | 33 | 30 | 27 | 33 | 29 | 27 |
08 | 39 | 32 | 27 | 31 | 27 | 24 | 30 | 27 | 24 |
09 | 36 | 29 | 25 | 28 | 25 | 22 | 28 | 24 | 22 |
10 | 34 | 27 | 23 | 26 | 22 | 20 | 26 | 22 | 20 |
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. | |||
45 | 4593. | 8186. | 8595. |
55 | 1424. | 3622. | 2527. |
65 | 554. | 530. | 413. |
75 | 327. | 250. | 154. |
85 | 286. | 171. | 114. |
CANDELA DISTRIBUTION0 |
|
| ||
| 0.0 | 45.0 | 90.0 | FLUX |
0 | 1287 | 1287 | 1287 |
|
5 | 1278 | 1327 | 1371 | 128 |
15 | 1217 | 1428 | 1504 | 398 |
25 | 1108 | 1471 | 1800 | 687 |
35 | 917 | 1503 | 1829 | 898 |
45 | 652 | 1162 | 1220 | 800 |
55 | 164 | 417 | 291 | 310 |
65 | 47 | 45 | 35 | 51 |
75 | 17 | 13 | 8 | 14 |
85 | 5 | 3 | 2 | 4 |
90 | 0 | 00 | 0 |
|
|
|
|
|
|
ZONAL LUMEN SUMMARY
ZONE | LUMENS | % LAMP | % FIXT |
1213 | 21.3 | 36.9 | |
2111 | 37.0 | 64.1 | |
3221 | 56.5 | 97.9 | |
3291 | 57.7 | 100.0 | |
0000 | 00.0 | 000.0 | |
3291 | 57.7 | 100.0 |
Ordering Information
Explanation of Catalog Number. Example: LL4MF8LR232120SOGLR
LL
R
*For any additional ballast or wiring combination consult factory. *8' units have lamps in tandem.
32
Lytecel |
|
|
|
|
| Number |
|
|
| Lamp Type/ |
|
|
| Options: |
Fixture |
|
| Body |
| Top | Lamp | Voltage: |
|
| |||||
Linear: | Length: |
|
| Finish: | of Cells: |
| Reflector: | Quantity* | Fixture Length: | 120 or 277 |
| Add appropriate | ||
Surface/ |
| F | =White | 8= 1 row of 8 |
| R=95% Reflective | 1=1 Lamp | 32=T82 | UNV = Universal |
| suffix to catalog | |||
4 = Nominal 48" |
|
|
| |||||||||||
Pendant |
| B | =Black | 12= 1 row of 12 |
| Aluminum Top | 2=2 Lamp | (Nominal 48") | Voltage |
| no, ie: (GLR) | |||
8 = Nominal 96" |
|
|
| |||||||||||
with 3” |
|
|
|
| (48” Length) |
| Reflector | 3=3 Lamp |
|
|
| |||
|
|
|
|
|
|
|
|
| ||||||
Deep Parabolic |
|
|
|
|
|
|
|
|
|
|
| <20THD | <10THD | |
| Body Style: |
|
|
| Louver Finish: |
|
|
|
| |||||
Precision |
|
|
|
|
|
|
| 1 or 2 Lamp Elec. T8 | SO* | HI* | ||||
|
|
|
|
|
|
| ||||||||
| M = Individual |
|
|
| L = Low Iridescence |
|
| |||||||
Contoured |
| Module |
|
|
|
|
|
| O3* | H3* | ||||
|
|
|
|
|
|
| ||||||||
| J = Joiner |
|
|
| (standard) |
|
|
| O4* | H4* | ||||
Aluminum Louver |
|
|
|
|
|
| ||||||||
Module |
|
|
| P = Low Iridescence |
|
| O6* | H6* | ||||||
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
| Specular |
|
|
| LOL Dimming T8 | PS | – | ||
|
|
|
|
|
| W=White |
|
|
| |||||
Options/accessories |
|
|
| Specifications (continued) | *Instant Start Standard | |||||||||
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
Stem Sets: 1/2” diameter tubing, 18” long, chrome plated finish. Catalog
Number: 18048.
Stem Extension Kit: 1/2" diameter tubing, 18” long, chrome plated finish
extension. Catalog Number: 18148.
Single Cable and Canopy. Catalog Number: WC60.Single Cable, Straight Cord and Canopy. Catalog Number: WCC60.
Single Cable, Coiled Cord and Canopy. Catalog Number: WCCC60.
Electrical Wiring Options: Consult factory.Fusing: Internal
Internal
Louver:
Finish:
Electrical: Thermally protected class “P” ballast, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W./UL and ULc Listed.
Specifications
Performance: In an installation of 2 lamp 32W Iuminaires with a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall be not less than .70. Candelas at 65° shall not exceed 100 (8 cell). To control veiling reflections, Iuminaire output in the 30°- 90° zone shall be not less than 65.5%. Materials: Chassis parts are
Job Information | Type: |
|
|
Lightolier a Genlyte company | www.lightolier.com |
Technical Information: (978)
631 Airport Road, Fall River, MA 02720 • (508)
© 2005 a Genlyte company A0902