Lightolier LOL99930 manual Lamp Data Chart, Application Notes, Model #, Rated, Initial, Common

Models: LOL99930

1 24
Download 24 pages 5.2 Kb
Page 22
Image 22
Lamp Data Chart

Lamp Data Chart

Lamp

Lamp

Model #

Rated

Initial

Common

CRI

Maximum Overall

Wattage

Manufacturer

(add color temperature

Life*

Lumens

Commercial/Institutionnal

 

Length

 

 

desired in space ____)

(hours)

at 25°C

Applications Color

 

inches (mm)

 

 

 

 

 

Temperatures (°K)

 

 

24

PHILIPS

F24T5/8__/HO/ALTO

20000

1800

3000, 3500, 4100

85

22.2" (563.2mm)

T5 High

GE

F24W/T5/8__/ECO

30000

1750

3000, 3500, 4100

85

22.2" (563.2mm)

Output

OSRAM Sylvania

FP24/8__/HO/ECO

20000

1750

3000, 3500, 4100

85

22.2" (563.2mm)

 

 

 

 

 

 

 

 

28

PHILIPS

F28T5/8__/ALTO

20000

2600

3000, 3500, 4100

85

45.8" (1163.2mm)

T5 High

GE

F28W/T5/8__/ECO

30000

2640

3000, 3500, 4100

85

45.8" (1163.2mm)

Efficiency

OSRAM Sylvania

FP28/8__/ECO

20000

2600

3000, 3500, 4100

85

45.8" (1163.2mm)

 

 

 

 

 

 

 

 

54

PHILIPS

F54T5/8__/HO/ALTO

25000

4500

3000, 3500, 4100

85

45.8" (1163.2mm)

T5 High

GE

F54W/T5/8__/ECO

30000

4460

3000, 3500, 4100

85

45.8" (1163.2mm)

Output

OSRAM Sylvania

FP54/HO/8__/ECO

25000

4450

3000, 3500, 4100

85

45.8" (1163.2mm)

 

 

 

 

 

 

 

 

17

PHILIPS

F17T8/TL8__/ALTO

24000

1400

3000, 3500, 4100

85

23.8" (604mm)

T8

GE

F17T8/SPX__/ECO

15000

1350

3000, 3500, 4100

86

23.8" (604mm)

 

OSRAM Sylvania

FO17/8__/ECO

15000

1350

3000, 3500, 4100

82

23.8" (604mm)

 

 

 

 

 

 

 

 

32

PHILIPS

F32T8/TL8__/ALTO

24000

2950

3000, 3500, 4100

85

47.8" (1213.6mm)

T8

GE

F32T8/SPX__/ECO

20000

2950

3000, 3500, 4100

86

47.8" (1213.6mm)

 

OSRAM Sylvania

FO32/8__/ECO

24000

2950

3000, 3500, 4100

85

47.8" (1213.6mm)

 

 

 

 

 

 

 

 

40

PHILIPS

PL-L 40W/8__/4P/RS/IS

20000

3300

3000, 3500, 4100

82

22.5" (571.5mm)

TT5

GE

F40/30BX/SPX__

20000

3150

3000, 3500, 4100

82

22.5" (571.5mm)

 

OSRAM Sylvania

FT40DL/8__/RS/ECO

20000

3150

3000, 3500, 4100

82

22.6" (573mm)

 

 

 

 

 

 

 

 

50

PHILIPS

PL-L 50W/8__/4P/RS

20000

4300

3000, 3500, 4100

82

22.5" (571.5mm)

TT5

GE

F50BX/SPX__RS

14000

4000

3000, 3500, 4100

82

22.5" (571.5mm)

 

OSRAM Sylvania

FT50DL/8__/RS/ECO

14000

4300

3000, 3500, 4100

82

22.6" (573mm)

 

 

 

 

 

 

 

 

55

PHILIPS

PL-L 55W/8__/4P/RS

10000

4800

3000, 3500, 4100

82

21.3" (541.6mm)

TT5

GE

F55BX/SPX__

10000

4800

3000, 3500, 4100

82

20.7" (525.7mm)

 

OSRAM Sylvania

FT55DL/8__/ECO

12000

4800

3000, 3500, 4100

82

21.1" (535mm)

 

 

 

 

 

 

 

 

LAMP CHART IS TO BE USED AS A GUIDE ONLY. LAMP MANUFACTURER DATA AT TIME OF PUBLICATION.

CHECK LAMP MANUFACTURER DATA FOR OTHER MODEL ENQUIRIES AND/OR EXACT SPECIFICATIONS.

*Rated average life under specified test conditions with lamps turned off and restarted no more frequently than once every 3 operating hours. Rating based on Program Start ballast for T5/T5HO, Instant Start for T8 and Rapid Start for TT5 lamps.

Application Notes

Results based on: Average footcandles maintained, total Light Loss Factor (L.L.F.)=0.82 Reflectances: 80% Ceiling (white acoustical tile), 50% Wall (off-white paint), 20% Floor (medium grey carpet). RE835 T8 lamps rated

at 2950 lumens, RE835 TT5 lamps rated at 3150 lumens, RE835 T5 lamps rated at 2600 lumens & RE835 T5HO lamps rated at 4500 lumens. 1' x 1' calculation grid at 30" from finished floor.

Results may vary.

Calculations have been performed according to IESNA & CIE standards and good practice. Some differences between measured values and calculated results may occur due to tolerances in calculation methods, testing procedures, component performance, measurement techniques and field conditions such as voltage and temperature variations. Input data used to generate the attached calculations such as room dimensions, reflectances, furniture and architectural elements significantly affect the lighting calculations. If the real environment conditions do not match

the input data, differences will occur between measured values and calculated values.

20

Page 22
Image 22
Lightolier LOL99930 manual Lamp Data Chart, Application Notes, Model #, Rated, Initial, Common