Lighting Systems
1BHFPG
Performance
CANDLEPOWER CURVE | ZONE 0 | CANDLEPOWER | 90 | |||
| 22 | 45 | 67 | |||
| DEG. |
| CANDELAS |
|
| |
|
|
|
|
| ||
| 180 | 1804 | 1804 | 1804 | 1804 | 1804 |
| 175 | 1781 | 1812 | 1841 | 1921 | 1910 |
| 165 | 1718 | 1886 | 2050 | 2215 | 2250 |
| 155 | 1603 | 1914 | 2230 | 2510 | 2570 |
| 145 | 1386 | 1846 | 2265 | 2490 | 2560 |
| 135 | 1106 | 1679 | 2025 | 2310 | 2375 |
| 125 | 875 | 1471 | 1865 | 2150 | 2130 |
| 115 | 568 | 1120 | 1461 | 1596 | 1635 |
| 105 | 287 | 740 | 931 | 987 | 997 |
| 95 | 66 | 236 | 257 | 250 | 253 |
| 90 | 21 | 26 | 37 | 42 | 48 |
| 85 | 11 | 30 | 40 | 50 | 53 |
| 75 | 33 | 41 | 54 | 67 | 71 |
| 65 | 44 | 53 | 68 | 81 | 85 |
| 55 | 102 | 102 | 119 | 731 | 131 |
| 45 | 117 | 118 | 124 | 137 | 140 |
| 35 | 150 | 150 | 154 | 160 | 163 |
| 25 | 173 | 173 | 175 | 177 | 178 |
REPORT NO: LRL | 15 | 189 | 187 | 189 | 189 | 190 |
CAT NO: LP2B4T84U | 5 | 197 | 194 | 196 | 195 | 195 |
LAMPS: 4 F32T8 | 0 | 195 | 195 | 195 | 195 | 195 |
LUMENS: 2900 |
|
|
|
|
|
|
EFFICIENCY: 80.7% |
|
|
|
|
|
|
COEFFICIENTS OF UTILIZATION
%EFFECTIVE CEILING CAVITY REFLECTANCE
|
|
|
| 80 |
|
|
| 70 |
|
|
| 50 |
|
|
|
|
|
|
| WALL REFLECTANCE |
|
|
| ||||||
|
|
| 70 | 50 | 30 |
| 70 | 50 | 30 |
| 50 | 30 | 10 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
RATIO | 0 |
| 78 | 78 | 78 |
| 68 | 68 | 68 |
| 48 | 48 | 48 | |
2 |
| 65 | 59 | 55 |
| 56 | 52 | 48 |
| 37 | 35 | 32 | ||
| 1 |
| 71 | 68 | 65 |
| 62 | 59 | 56 |
| 42 | 41 | 39 | |
CAVITY | 3 |
| 59 | 52 | 47 |
| 51 | 45 | 41 |
| 32 | 30 | 27 | |
4 |
| 54 | 46 | 40 |
| 46 | 40 | 35 |
| 29 | 25 | 23 | ||
|
|
|
| |||||||||||
| 5 |
| 49 | 40 | 34 |
| 42 | 35 | 30 |
| 25 | 22 | 19 | |
ROOM | 6 |
| 45 | 36 | 30 |
| 39 | 31 | 26 |
| 23 | 19 | 17 | |
7 |
| 41 | 32 | 26 |
| 36 | 28 | 23 |
| 20 | 17 | 14 | ||
|
|
|
| |||||||||||
| 8 |
| 38 | 29 | 23 |
| 33 | 25 | 20 |
| 18 | 15 | 12 | |
| 9 |
| 35 | 26 | 20 |
| 30 | 23 | 18 |
| 16 | 13 | 11 | |
| 10 |
| 33 | 24 | 18 |
| 28 | 21 | 16 |
| 15 | 12 | 10 | |
|
|
|
|
20% FLOOR CAVITY REFLECTANCE
DISTRIBUTION | % Lamp | % Luminaire | |
Zone | Lumens | ||
754 | 6.5 | 8.1 | |
8609 | 74.2 | 91.9 | |
9363 | 80.7 | 100.0 |
Fixture Lengths & Mounting Locations
|
|
|
|
|
|
| 48” (121.92cm) |
|
|
|
|
|
|
|
|
|
|
| 96” (243.84cm) |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
4’ |
|
|
|
|
|
|
|
|
|
|
| 8’ |
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
| 4’ 2” (127.00cm) |
|
|
|
|
|
|
|
|
|
|
| 8’ 2” (248.92cm) |
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
96” (243.84cm) 48” (121.92cm)
12’
12’ 2” (370.84cm)
96” (243.84cm) 96” (243.84cm)
16’
16’ 2” (492.76cm)
1 |
|
| 1 |
1 | 1 |
| 2 |
12
3
End Set
1
1
1
1
1
1
Cable/ Joiner
1
1
2
2
96” (243.84cm) | 96” (243.84cm) | 48” (121.92cm) | |
20’ | 20’ 2” (614.68cm) |
| |
|
| ||
96” (243.84cm) | 96” (243.84cm) | 96” (243.84cm) | |
24’ | 24’ 2” (736.60cm) |
| |
|
| ||
Mounting Accessories |
|
| |
Cable/Joiner Assembly | Power Feed End Set | Ceiling Grid Kit | |
Standard Cable Length is 36” (91.44cm) | Standard Cable Length is 36” (91.44cm) | ||
CGK | |||
Single Cable: LP2C36 | Straight Cord: LP2EC36 | ||
Includes both Standard 1” (2.54cm) | |||
Single Cable & Cord: LP2CC36 | 4 Wire Cord*: LP2EC36X4 | ||
Tee Bar Clip & Slot Tee Clip | |||
Single Cable & 4 Wire Cord: LP2CC36X4 | * use for dimming and/or |
| |
| emergency battery packs |
|
Job Information | Type: |
"JSQPSU3PBE'BMM3JWFS."t t'BY
We reserve the right to change details of design, materials and finish.
XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt #