Lighting Systems
1BHFPG |
Performance
CANDLEPOWER CURVE | ZONE 0 | CANDLEPOWER | 90 | |||
| 22 | 45 | 67 | |||
| DEG. |
| CANDELAS |
|
| |
|
|
|
|
| ||
| 180 | 2035 | 2035 | 2035 | 2035 | 2035 |
| 175 | 2025 | 2051 | 2059 | 2109 | 2111 |
| 165 | 1967 | 2146 | 2224 | 2302 | 2294 |
| 155 | 1829 | 2084 | 2186 | 2336 | 2366 |
| 145 | 1605 | 1912 | 2084 | 2342 | 2398 |
| 135 | 1318 | 1654 | 1907 | 2239 | 2308 |
| 125 | 1057 | 1423 | 1775 | 2209 | 2210 |
| 115 | 719 | 1129 | 1545 | 1945 | 2036 |
| 105 | 397 | 813 | 1234 | 1346 | 1372 |
| 95 | 106 | 288 | 367 | 275 | 294 |
| 90 | 29 | 27 | 44 | 49 | 52 |
| 85 | 11 | 35 | 46 | 58 | 64 |
| 75 | 34 | 50 | 65 | 82 | 87 |
| 65 | 44 | 61 | 83 | 99 | 105 |
| 55 | 103 | 110 | 126 | 147 | 148 |
| 45 | 120 | 125 | 133 | 146 | 150 |
| 35 | 152 | 156 | 162 | 170 | 174 |
| 25 | 175 | 177 | 188 | 186 | 186 |
REPORT NO: LRL | 15 | 193 | 193 | 196 | 199 | 199 |
CAT NO: LP2B2BX4U | 5 | 201 | 193 | 196 | 199 | 199 |
LAMPS: 4 F40BX | 0 | 199 | 199 | 199 | 199 | 199 |
LUMENS: 3150 |
|
|
|
|
|
|
EFFICIENCY: 77.7%
COEFFICIENTS OF UTILIZATION
%EFFECTIVE CEILING CAVITY REFLECTANCE
|
|
|
| 80 |
|
|
| 70 |
|
|
| 50 |
|
|
|
|
|
| WALL REFLECTANCE |
|
|
| |||||||
|
|
| 70 | 50 | 30 |
| 70 | 50 | 30 |
| 50 | 30 | 10 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
RATIO | 0 |
| 75 | 75 | 75 |
| 65 | 65 | 65 |
| 46 | 46 | 46 | |
2 |
| 62 | 57 | 53 |
| 54 | 49 | 46 |
| 35 | 33 | 31 | ||
| 1 |
| 68 | 65 | 62 |
| 59 | 56 | 54 |
| 40 | 39 | 37 | |
CAVITY | 3 |
| 57 | 50 | 45 |
| 49 | 43 | 39 |
| 31 | 28 | 26 | |
4 |
| 52 | 44 | 38 |
| 44 | 38 | 33 |
| 27 | 24 | 22 | ||
|
|
|
| |||||||||||
| 5 |
| 47 | 39 | 33 |
| 41 | 34 | 29 |
| 24 | 21 | 19 | |
ROOM | 6 |
| 43 | 35 | 29 |
| 37 | 30 | 25 |
| 22 | 18 | 16 | |
7 |
| 40 | 31 | 25 |
| 34 | 27 | 22 |
| 19 | 16 | 14 | ||
|
|
|
| |||||||||||
| 8 |
| 37 | 28 | 22 |
| 32 | 24 | 19 |
| 17 | 14 | 12 | |
| 9 |
| 34 | 25 | 20 |
| 29 | 22 | 17 |
| 16 | 13 | 11 | |
| 10 |
| 32 | 23 | 18 |
| 27 | 20 | 16 |
| 14 | 11 | 9 |
|
|
|
|
|
| ||||||||||
|
|
| 20% FLOOR CAVITY REFLECTANCE |
|
| |||||||||
DISTRIBUTION |
|
| % Lamp |
|
| % Luminaire | ||||||||
Zone |
| Lumens |
|
|
| |||||||||
| 675 |
|
|
| 5.3 |
|
|
| 6.9 |
|
| |||
9118 |
|
|
| 72.4 |
|
|
| 93.1 |
|
| ||||
9793 |
|
|
| 77.7 |
|
|
| 100.0 |
|
|
Fixture Lengths & Mounting Locations
|
|
|
|
|
|
| 48” (121.92cm) |
|
|
|
|
|
|
|
|
|
|
| 96” (243.84cm) |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
4’ |
|
|
|
|
|
|
|
|
|
|
| 8’ |
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
| 4’ 2” (127.00cm) |
|
|
|
|
|
|
|
|
|
|
| 8’ 2” (248.92cm) |
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
96” (243.84cm) 48” (121.92cm)
12’
12’ 2” (370.84cm)
96” (243.84cm) 96” (243.84cm)
16’
16’ 2” (492.76cm)
1 |
|
| 1 |
1 | 1 |
| 2 |
12
3
End Set
1
1
1
1
1
1
Cable/ Joiner
1
1
2
2
96” (243.84cm) | 96” (243.84cm) | 48” (121.92cm) | |
20’ | 20’ 2” (614.68cm) |
| |
|
| ||
96” (243.84cm) | 96” (243.84cm) | 96” (243.84cm) | |
24’ | 24’ 2” (736.60cm) |
| |
|
| ||
Mounting Accessories |
|
| |
Cable/Joiner Assembly | Power Feed End Set | Ceiling Grid Kit | |
Standard Cable Length is 36” (91.44cm) | Standard Cable Length is 36” (91.44cm) | ||
CGK | |||
Single Cable: LP2C36 | Straight Cord: LP2EC36 | ||
Includes both Standard 1” (2.54cm) | |||
Single Cable & Cord: LP2CC36 | 4 Wire Cord*: LP2EC36X4 | ||
Tee Bar Clip & Slot Tee Clip | |||
Single Cable & 4 Wire Cord: LP2CC36X4 | * use for dimming and/or |
| |
| emergency battery packs |
|
Job Information | Type: |
"JSQPSU3PBE'BMM3JWFS."t t'BY
We reserve the right to change details of design, materials and finish.
XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt #