Lighting Systems
1BHFPG
Performance
CANDLEPOWER CURVE |
|
| CANDLEPOWER |
|
|
|
| COEFFICIENTS OF UTILIZATION |
| ||||||||
| ZONE 0 | 22 | 45 | 67 | 90 |
|
|
| % EFFECTIVE CEILING CAVITY |
| |||||||
| DEG. |
| CANDELAS |
|
|
|
|
|
| REFLECTANCE |
|
| |||||
|
|
|
|
|
|
|
| 80 |
|
| 70 |
|
| 50 |
| ||
| 180 | 1107 | 1107 | 1107 | 1107 | 1107 |
|
|
|
|
|
|
|
| |||
| 175 | 1109 | 1108 | 1111 | 1110 | 1110 |
|
|
|
| WALL REFLECTANCE |
|
| ||||
| 165 | 1072 | 1079 | 1097 | 1107 | 1105 |
|
| 70 | 50 | 30 | 70 | 50 | 30 | 50 | 30 | 10 |
| 155 | 996 | 1015 | 1045 | 1084 | 1092 | RATIO | 0 | 80 | 80 | 80 | 71 | 71 | 71 | 53 | 53 | 53 |
| 135 | 713 | 778 | 840 | 914 | 926 | 2 | 67 | 61 | 57 | 59 | 54 | 50 | 41 | 38 | 36 | |
| 145 | 875 | 919 | 972 | 1032 | 1049 |
| 1 | 73 | 70 | 67 | 64 | 62 | 59 | 46 | 45 | 43 |
| 125 | 573 | 639 | 726 | 790 | 762 | CAVITY | 3 | 61 | 54 | 49 | 54 | 48 | 43 | 36 | 33 | 31 |
| 115 | 392 | 475 | 536 | 591 | 610 | 4 | 56 | 48 | 42 | 49 | 42 | 37 | 32 | 29 | 26 | |
| 105 | 208 | 285 | 356 | 433 | 448 |
| 5 | 51 | 42 | 36 | 45 | 38 | 32 | 29 | 25 | 22 |
| 95 | 41 | 112 | 135 | 156 | 161 | ROOM | 6 | 47 | 38 | 32 | 41 | 34 | 28 | 26 | 22 | 19 |
| 90 | 0 | 18 | 33 | 48 | 55 | 7 | 43 | 34 | 28 | 38 | 30 | 25 | 23 | 20 | 17 | |
| 85 | 8 | 19 | 28 | 40 | 45 |
| 8 | 40 | 31 | 25 | 35 | 27 | 22 | 21 | 17 | 15 |
| 75 | 29 | 37 | 54 | 70 | 75 |
| 9 | 37 | 28 | 22 | 33 | 25 | 20 | 19 | 16 | 13 |
| 65 | 59 | 70 | 89 | 105 | 111 |
| 10 | 34 | 25 | 20 | 30 | 22 | 18 | 17 | 14 | 11 |
| 55 | 129 | 133 | 147 | 165 | 165 |
|
| 20% FLOOR CAVITY REFLECTANCE |
| |||||||
| 45 | 177 | 180 | 186 | 198 | 202 | DISTRIBUTION |
|
|
|
|
|
|
| |||
| 35 | 237 | 239 | 243 | 250 | 253 |
|
|
|
|
|
|
| ||||
REPORT NO: LRL | 25 | 282 | 282 | 284 | 288 | 289 | Zone | Lumens | % Lamp |
| % Luminaire | ||||||
15 | 313 | 314 | 314 | 316 | 315 |
| 859 |
| 14.8 |
| 18.3 |
| |||||
CAT NO: LP2C2T84U | 5 | 331 | 330 | 331 | 328 | 330 |
| 65.9 |
| 81.7 |
| ||||||
LAMPS: 2 F32T8 |
|
|
| ||||||||||||||
LUMENS: 2900 | 0 | 330 | 330 | 330 | 330 | 330 | 4681 |
| 80.7 |
| 100.0 |
|
EFFICIENCY: 80.7%
Fixture Lengths & Mounting Locations
|
|
|
|
|
|
| 48” (121.92cm) |
|
|
|
|
|
|
|
|
|
|
| 96” (243.84cm) |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
4’ |
|
|
|
|
|
|
|
|
|
|
| 8’ |
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
| 4’ 2” (127.00cm) |
|
|
|
|
|
|
|
|
|
|
| 8’ 2” (248.92cm) |
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
96” (243.84cm) 48” (121.92cm)
12’
12’ 2” (370.84cm)
96” (243.84cm) 96” (243.84cm)
16’
16’ 2” (492.76cm)
1 |
|
| 1 |
1 | 1 |
| 2 |
12
3
End Set
1
1
1
1
1
1
Cable/ Joiner
1
1
2
2
96” (243.84cm) | 96” (243.84cm) | 48” (121.92cm) | |
20’ | 20’ 2” (614.68cm) |
| |
|
| ||
96” (243.84cm) | 96” (243.84cm) | 96” (243.84cm) | |
24’ | 24’ 2” (736.60cm) |
| |
|
| ||
Mounting Accessories |
|
| |
Cable/Joiner Assembly | Power Feed End Set | Ceiling Grid Kit | |
Standard Cable Length is 36” (91.44cm) | Standard Cable Length is 36” (91.44cm) | ||
CGK | |||
Single Cable: LP2C36 | Straight Cord: LP2EC36 | ||
Includes both Standard 1” (2.54cm) | |||
Single Cable & Cord: LP2CC36 | 4 Wire Cord*: LP2EC36X4 | ||
Tee Bar Clip & Slot Tee Clip | |||
Single Cable & 4 Wire Cord: LP2CC36X4 | * use for dimming and/or |
| |
| emergency battery packs |
|
Job Information | Type: |
"JSQPSU3PBE'BMM3JWFS."t t'BY
We reserve the right to change details of design, materials and finish.